00:00:12.730 00:00:12.740 hello this is matt from a suppliant in
00:00:15.259 00:00:15.269 toledo ohio welcome back to another in
00:00:17.540 00:00:17.550 diagnostic video brought to you by
00:00:19.550 00:00:19.560 appliance video comm
00:00:22.160 00:00:22.170 what we have here is an Amana top
00:00:24.650 00:00:24.660 freezer customer's complaint is that the
00:00:27.859 00:00:27.869 refrigerator section is not cooling and
00:00:30.830 00:00:30.840 the first thing we did and kind of
00:00:33.110 00:00:33.120 listen you can hear the compressor
00:00:34.490 00:00:34.500 itself is running when you open the
00:00:39.380 00:00:39.390 freezer door not here in the fan motor
00:00:44.119 00:00:44.129 the evaporator fan running and that's
00:00:47.030 00:00:47.040 going to be what's going to pull the
00:00:48.319 00:00:48.329 cold air from the freezer section down
00:00:50.569 00:00:50.579 to the refrigerator you can see some of
00:00:53.600 00:00:53.610 the excessive kind of moisture
00:00:57.470 00:00:57.480 condensation frost that's building up
00:00:59.959 00:00:59.969 and around the base here there's a lot
00:01:02.270 00:01:02.280 of ice
00:01:02.959 00:01:02.969 looks like the drain line might be
00:01:04.729 00:01:04.739 frozen a lot of times that will happen
00:01:06.800 00:01:06.810 when the evaporator fan motor ties up so
00:01:09.830 00:01:09.840 we're going to take the back panel off
00:01:11.120 00:01:11.130 here check power to the fan motor and
00:01:15.999 00:01:16.009 confirm that that's going to be the
00:01:17.749 00:01:17.759 issue but it looks like that's what
00:01:19.430 00:01:19.440 we're going to be dealing with
00:01:28.430 00:01:28.440 you
00:01:42.710 00:01:42.720 and you can kind of like said notice
00:01:44.870 00:01:44.880 that there's ice around thee this is
00:01:47.330 00:01:47.340 basically your air passage that connects
00:01:49.730 00:01:49.740 the refrigerator and freezer and there's
00:01:52.730 00:01:52.740 ice all around here so it's going to be
00:01:54.560 00:01:54.570 kind of tough to get this panel off and
00:01:56.150 00:01:56.160 that's usually a pretty good indication
00:01:58.250 00:01:58.260 that the evaporator fan motor is stalled
00:02:02.650 00:02:02.660 a shelf here and we've got two quarters
00:02:13.570 00:02:13.580 on the back panel and we're gonna take
00:02:20.210 00:02:20.220 the one out for the icemaker cover make
00:02:24.770 00:02:24.780 sure see there that's gotta be
00:02:31.160 00:02:31.170 disconnected then the tab back just tabs
00:02:35.570 00:02:35.580 on each side that would just be a
00:02:38.330 00:02:38.340 harness for an icemaker grab right here
00:02:44.930 00:02:44.940 and pull straight back you got this
00:02:50.240 00:02:50.250 whole kind of hard and you got a ground
00:02:52.699 00:02:52.709 wire that's connected up in this top
00:02:54.530 00:02:54.540 left hand corner and we've got just a
00:02:56.750 00:02:56.760 ground wire that's holding the panel
00:02:58.220 00:02:58.230 right now let's kind of reach behind and
00:03:02.710 00:03:02.720 pull that off the panel there alright
00:03:09.560 00:03:09.570 well right now like I said the
00:03:11.270 00:03:11.280 compressor is running and the easy way
00:03:14.449 00:03:14.459 to check on a fan motor is just try it
00:03:16.850 00:03:16.860 spin it and that should spin very freely
00:03:21.620 00:03:21.630 I should be able that let's get it going
00:03:25.280 00:03:25.290 this fan motor is definitely tied up so
00:03:29.420 00:03:29.430 we will need to replace the evaporator
00:03:31.340 00:03:31.350 fan okay before we go any further you're
00:03:34.400 00:03:34.410 just gonna go ahead and unplug the unit
00:03:40.940 00:03:40.950 because we have confirmed the evaporator
00:03:43.350 00:03:43.360 fan motor is bad okay to remove the
00:03:46.710 00:03:46.720 evaporator fan so we've got two screws
00:03:51.300 00:03:51.310 here that are holding the mounting
00:03:53.100 00:03:53.110 bracket and you just kind of have to
00:03:55.890 00:03:55.900 unweave this wiring it's sort of strung
00:03:59.640 00:03:59.650 up through here
00:04:04.369 00:04:04.379 these are quarter-inch you look and see
00:04:14.910 00:04:14.920 how the wiring is sort of weaved up
00:04:16.830 00:04:16.840 around there
00:04:29.240 00:04:29.250 00:04:34.000 00:04:34.010 once you have all that free the only
00:04:37.490 00:04:37.500 thing that's holding the two power
00:04:40.190 00:04:40.200 connectors and the ground wire good
00:04:44.480 00:04:44.490 connections are just kind of hard to get
00:04:45.770 00:04:45.780 off so we grab a pair of needlenose just
00:04:48.620 00:04:48.630 get a good grip on them and as far as
00:05:02.180 00:05:02.190 your two power wires are concerned
00:05:05.530 00:05:05.540 obviously your ground terminals a little
00:05:08.060 00:05:08.070 bit smaller the new fan might not even
00:05:10.460 00:05:10.470 have a ground like that but yeah doesn't
00:05:13.700 00:05:13.710 matter no white in the red because one's
00:05:16.610 00:05:16.620 just line voltage and the other ones
00:05:18.080 00:05:18.090 neutral so to mix them up and put them
00:05:20.690 00:05:20.700 in different order it doesn't make a
00:05:22.010 00:05:22.020 difference
00:05:30.770 00:05:30.780 00:09:09.079 00:09:09.089 00:14:00.030 00:14:00.040 thank you for watching another quality
00:14:02.040 00:14:02.050 video from appliance video comm
00:14:04.050 00:14:04.060
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12

Phone: +7 343 216 77 75

E-mail: info@lotus1.ru

Sales phone

Russia: +7 343 216 77 75

WhatsApp: +79122710308