/ News & Press / Video / Cleaning all in one outside unit evaporator and condenser coil - Package Unit Air conditioner AC
Cleaning all in one outside unit evaporator and condenser coil - Package Unit Air conditioner AC
WEBVTT Kind: captions Language: en
00:00:00.380 so I have a outdoor units AC unit right 00:00:05.03000:00:05.040 here and we're going to wash the 00:00:08.45000:00:08.460 evaporator coils I believe so to do so I 00:00:12.08000:00:12.090 guess we're going to take off the top 00:00:14.89000:00:14.900 before we start all of this we want to 00:00:17.68900:00:17.699 turn off the power and you open up your 00:00:20.48000:00:20.490 a junction box and you just pull the 00:00:22.70000:00:22.710 lever out to kill the power working with 00:00:24.56000:00:24.570 a trained model which is basically the 00:00:27.32000:00:27.330 the name of it but the parent company is 00:00:29.26900:00:29.279 called American Standard and I just kind 00:00:31.42900:00:31.439 of let you know this is a why CC 0 3 6 5 00:00:34.54900:00:34.559 1 M 0 BK and that'll be in the summary 00:00:38.24000:00:38.250 notes for you to take a look at but this 00:00:39.65000:00:39.660 is an all-in-one unit with the air 00:00:41.63000:00:41.640 conditioning and the heater built in one 00:00:56.97900:00:56.989 so as we lift this up there's the fan 00:01:00.59000:01:00.600 right here disconnected 00:01:12.21900:01:12.229 so the circuit board is right here and 00:01:15.05000:01:15.060 to start like in the run start 00:01:16.49000:01:16.500 capacitors down there and the heating 00:01:19.07000:01:19.080 unit where it takes to the natural gas 00:01:21.23000:01:21.240 and heats up your air goes through here 00:01:24.20000:01:24.210 and the glasses right here and then 00:01:28.94000:01:28.950 that's your compressor and what here's 00:01:31.82000:01:31.830 the furnace those tubes are furnace 00:01:34.73000:01:34.740 right there the blower is right there 00:01:37.66900:01:37.679 and the evaporator coil is right there 00:01:41.10900:01:41.119 the air intake comes from here and you 00:01:44.18000:01:44.190 can see the bugs and everything so we're 00:01:47.38900:01:47.399 going to clean this so right now we are 00:01:50.87000:01:50.880 going to mix the solution and it's one 00:01:54.74000:01:54.750 part cleaner so three to six parts water 00:01:57.88000:01:57.890 so we have that's our one part 00:02:05.48000:02:05.490 so that's about one two four or five 00:02:08.37000:02:08.380 part strange yeah sure so now we're 00:02:11.67000:02:11.680 going to spray from since the air is 00:02:14.58000:02:14.590 going from this direction we're going to 00:02:16.26000:02:16.270 spray on the other end 00:02:18.16000:02:18.170 [Music] 00:02:32.27000:02:32.280 you can spray the other end from an 00:02:35.73000:02:35.740 angle 00:02:41.24000:02:41.250 they just won't fully saturate the 00:02:45.93000:02:45.940 evaporator coil and you want to throw to 00:02:50.22000:02:50.230 dirt off and let it soak for 5 minutes 00:02:56.43000:02:56.440 or so then we'll rinse it down with 00:02:58.26000:02:58.270 water 00:03:06.46000:03:06.470 since we still have more solution we're 00:03:08.78000:03:08.790 just going to go ahead and clean the 00:03:11.20000:03:11.210 condensing coil as well - we're gonna 00:03:26.06000:03:26.070 rinse it using a water hose and this is 00:03:27.98000:03:27.990 just for the outdoor unit otherwise you 00:03:30.65000:03:30.660 should probably use sprayer full clean 00:03:33.35000:03:33.360 water to clean it so we're just going to 00:03:35.81000:03:35.820 let it flow from the top down and it's 00:03:40.52000:03:40.530 going to come out the drain pipe through 00:03:44.06000:03:44.070 the drain pan this is after you let it 00:03:46.70000:03:46.710 soak for a little while 00:04:30.18000:04:30.190 so this is the end result of the 00:04:32.56000:04:32.570 evaporator coil and it's extremely clean 00:04:35.64000:04:35.650 compared to before so and the condensing 00:04:41.86000:04:41.870 coil is also a lot cleaner right now and 00:04:44.50000:04:44.510 we're just going to put the top on 00:04:49.22000:04:49.23000:04:56.61000:04:56.62000:05:08.93000:05:08.940
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12