How to Install a Combination Boiler Baxi Gas Combi Boiler Installation

WEBVTT
Kind: captions
Language: en

00:00:01.429 --> 00:00:06.810
My name is Allen Hart and today we're
working in Otley near Leeds and we'll
00:00:06.810 --> 00:00:12.269
just install a new combi boiler so we've
got a nice flat wall here today so we're
00:00:12.269 --> 00:00:20.910
just gonna show you step by step how we
do it so the first thing and one of the
00:00:20.910 --> 00:00:28.560
most important things we protect the
property we've got a bucket Platinum
00:00:28.560 --> 00:00:33.470
there so that's the boiler that what is
Darwin today
00:00:48.480 --> 00:00:57.059
and then when we open this just finds
back with all the useful things ooh I
00:00:57.059 --> 00:01:10.000
love your fitness pack on this just
slides out so if we see that all the
00:01:10.000 --> 00:01:14.380
Bible is still in the box so the pilot
can be just kept nice and safe
00:01:14.380 --> 00:01:21.850
well we fit the jig oh and then just
mark all this out so there's a level
00:01:21.850 --> 00:01:27.580
here so we can easily level the pilot
Rob so one thing to point out with this
00:01:27.580 --> 00:01:33.490
it must be installed by gas a registered
engineer if it's not installed by gas a
00:01:33.490 --> 00:01:38.200
registered engineer then you will have
no warrants with the boiler and you will
00:01:38.200 --> 00:01:42.580
also if you come to sell your property
you will have that the right
00:01:42.580 --> 00:01:47.200
certification that you'll need to
actually sell the property so always
00:01:47.200 --> 00:01:52.319
make sure that you have it done by gas
therefore interested engineer
00:02:04.080 --> 00:02:07.510
so we have up to our car drill move us
to there
00:02:07.510 --> 00:02:14.730
so what we'll do is we'll just stitch
that so we drilled a load of six mill
00:02:14.730 --> 00:02:23.490
pilot bits all around on a flow so it's
nice and Nate is out
00:03:00.640 --> 00:03:07.190
so I've put the straps back on the box
and left the farm stuff in the bottom
00:03:07.190 --> 00:03:17.060
and now to use that has been key pop
rice together so I've just got scaps to
00:03:17.060 --> 00:03:32.540
take out the bottle here but what
without these are tested before the come
00:03:32.540 --> 00:03:39.590
out so you should never have a fault
fault it won't come install because I've
00:03:39.590 --> 00:03:54.490
all been tested and now we're just going
to come off just don't get bent
00:04:11.400 --> 00:04:19.540
so what we normally find is these notes
on this boxer dog by not very well so
00:04:19.540 --> 00:04:35.500
you can't just tie them off in my mind
so all you need to do is see the nuts on
00:04:35.500 --> 00:04:41.860
the back just slack on them nuts off and
then you'll be able to connect it up
00:04:41.860 --> 00:05:23.139
very easily on the back of the vowel so
if you collected all their mum now so
00:05:23.139 --> 00:05:27.760
now we can just nip them all off and
then just take them back knocks back up
00:05:27.760 --> 00:05:33.910
I will I always do this first before I
connected it back to it because if we
00:05:33.910 --> 00:05:38.650
connect the pipes to it it can be quite
awkward to get them to line up so this
00:05:38.650 --> 00:05:43.950
is just the way I do it
so just connected the pressure-relief
00:05:43.950 --> 00:05:53.320
pipe if you see there he's bent so these
always come twisted I'll Bend on the on
00:05:53.320 --> 00:05:57.970
the back see boilers and so you can if
you want there's a little grub screw
00:05:57.970 --> 00:06:04.210
there you can just undo that and you can
straighten it up a little bit or you can
00:06:04.210 --> 00:06:07.660
just try and Bend this pipe a little bit
all the things I've seen I've seen
00:06:07.660 --> 00:06:14.020
people cut this and then just pull sake
I'm just destroying it up by the one so
00:06:14.020 --> 00:06:19.900
I've actually just twisted the pipe a
little bit so I've just drilled for the
00:06:19.900 --> 00:06:24.260
blow-off now
and we'll just slave that and we're just
00:06:24.260 --> 00:06:30.730
gonna put some non saying mistake in
that we do on the carpets can we contact
00:06:30.730 --> 00:06:40.190
with the cement because the cement will
corrode the copper over time so we just
00:06:40.190 --> 00:06:43.520
don't work pipes now so cause perhaps
fault sir
00:06:43.520 --> 00:06:50.210
but is that there's Phenix
I mean you fill its up and then we're
00:06:50.210 --> 00:07:03.770
just going to do a gas now so we've got
a pilot from running now so we're just
00:07:03.770 --> 00:07:10.180
gonna check the emissions we just got
scared and I do that
00:07:13.880 --> 00:07:20.490
we've also got pushing it after on that
00:07:20.490 --> 00:07:27.020
hostile shit system along the cleanse
00:07:30.190 --> 00:07:35.590
so we just finished enough now so I've
installed this box this box it platinum
00:07:35.590 --> 00:07:41.210
so this box of platinum cause of a ten
year parts and labor warranty we've also
00:07:41.210 --> 00:07:46.790
got we've installed the FIR Knox filter
so the phonon filter come from a 25 year
00:07:46.790 --> 00:07:54.040
warranty and we've also put we've
cleaned it out with fir Knox f5 and
00:07:54.040 --> 00:08:01.700
we've also added fir Knox inhibitor f1
protector in afterwards so that I'll
00:08:01.700 --> 00:08:08.240
protect the system thank you for taking
the time to watch our video helpful
00:08:08.240 --> 00:08:11.980
install a combi boiler