How To Install A Plate Heat Exchangers To A Domestic Hot Water Tank

WEBVTT
Kind: captions
Language: en

00:00:09.700
you
00:00:15.340 00:00:15.350 hey Jeff love here from alternative
00:00:17.690 00:00:17.700 heating and supplies again we're going
00:00:19.460 00:00:19.470 to be talking about how to install a
00:00:20.810 00:00:20.820 plate exchanger on top of a domestic hot
00:00:22.730 00:00:22.740 water tank this time and this is another
00:00:24.980 00:00:24.990 big call that again a lot of questions
00:00:26.510 00:00:26.520 about it but this is so simple it should
00:00:29.630 00:00:29.640 be pretty quick to show you now once I
00:00:31.130 00:00:31.140 give you a visual everybody it clicks
00:00:32.930 00:00:32.940 and everybody gets it what I have here
00:00:35.030 00:00:35.040 is I'm going to be using a 20 plate heat
00:00:37.100 00:00:37.110 exchanger now a lot of people ask me how
00:00:40.010 00:00:40.020 do you know what size play exchanger to
00:00:41.930 00:00:41.940 install in your domestic hot water tank
00:00:43.430 00:00:43.440 simple rule of thumb is two to three
00:00:46.010 00:00:46.020 people in one house will determine a 10
00:00:48.680 00:00:48.690 plate a 10 plate heat exchangers enough
00:00:50.660 00:00:50.670 for 2 or 3 people when you get into a
00:00:53.000 00:00:53.010 full size family anywhere from 4 or 5 6
00:00:55.220 00:00:55.230 people in the house I immediately
00:00:56.510 00:00:56.520 recommend the 20 plate it will have
00:00:58.460 00:00:58.470 plenty of power it'll have a good
00:01:00.460 00:01:00.470 regenerative nature to it so will heat
00:01:02.870 00:01:02.880 up the domestic hot water a lot faster
00:01:04.460 00:01:04.470 this is the cold water side so cold
00:01:07.580 00:01:07.590 water coming in obviously the plate
00:01:10.580 00:01:10.590 exchangers are installed I didn't want
00:01:11.870 00:01:11.880 to show you how to screw everything
00:01:13.819 00:01:13.829 together I'm sure you all could figure
00:01:14.960 00:01:14.970 all that how to do it this is your hot
00:01:17.179 00:01:17.189 water side so you're going to mount your
00:01:19.160 00:01:19.170 your plate exchanger on the cold water
00:01:21.530 00:01:21.540 side and I'll explain to you why it's
00:01:23.840 00:01:23.850 actually quite simple I call it a
00:01:25.190 00:01:25.200 thermal pressure siphon explained in
00:01:27.290 00:01:27.300 detail in just a minute so all you're
00:01:29.120 00:01:29.130 going to do is the water line will come
00:01:30.560 00:01:30.570 in and you're going to just cut it
00:01:31.640 00:01:31.650 you're going to mount it you're going to
00:01:32.810 00:01:32.820 do a 90 here going into the plate
00:01:35.149 00:01:35.159 exchanger and I always recommend unions
00:01:36.950 00:01:36.960 now you've got to use a lead-free copper
00:01:42.230 00:01:42.240 and also brass in this case of this
00:01:44.450 00:01:44.460 application I carry brass lead-free
00:01:46.850 00:01:46.860 brass so I use brass here to give you
00:01:48.590 00:01:48.600 this example so you're going to put a
00:01:51.020 00:01:51.030 union here and then you come down in
00:01:52.490 00:01:52.500 through the plate changer and then again
00:01:54.320 00:01:54.330 another lead-free Union and then back
00:01:56.450 00:01:56.460 into the plate into the domestic hot
00:01:58.700 00:01:58.710 water tank
00:01:59.500 00:01:59.510 these plague exchangers are stainless
00:02:01.550 00:02:01.560 steel the place changes that I sell are
00:02:04.160 00:02:04.170 also 40% heavier than the plate
00:02:06.289 00:02:06.299 exchangers else that are out there on
00:02:07.550 00:02:07.560 the market the plate exchangers can be
00:02:08.839 00:02:08.849 used for many different applications
00:02:09.919 00:02:09.929 anything from cooling or heating and
00:02:13.039 00:02:13.049 warming up diesel to exchanging heat
00:02:15.470 00:02:15.480 between polyurethane and an ax fridge
00:02:18.199 00:02:18.209 Hrant and everything else but the heat
00:02:20.089 00:02:20.099 exchangers that I have made specifically
00:02:22.160 00:02:22.170 for me is made for the wood boiler
00:02:24.559 00:02:24.569 application so it's a much heavier grade
00:02:26.690 00:02:26.700 of plate exchanger which hurts my
00:02:28.800 00:02:28.810 efficiency a little bit but I'd rather
00:02:31.530 00:02:31.540 have the longevity and the quality and
00:02:34.199 00:02:34.209 then instead of having to replace of
00:02:35.610 00:02:35.620 every four or five years is what it
00:02:37.290 00:02:37.300 seems like the other ones that I've come
00:02:38.880 00:02:38.890 across are the less expensive or the
00:02:40.559 00:02:40.569 lighter ones that I've seen so I went
00:02:43.500 00:02:43.510 with a heavier grade and they should
00:02:45.240 00:02:45.250 last you the lifetime of the boiler if
00:02:46.860 00:02:46.870 not longer so in this case the water
00:02:51.150 00:02:51.160 flow is going to be coming in from the
00:02:52.589 00:02:52.599 domestic hot water side this way into it
00:02:55.440 00:02:55.450 so the flow of the wood boiler is going
00:02:58.140 00:02:58.150 to go the opposite direction you're
00:03:00.870 00:03:00.880 trying to create a cross flow difference
00:03:02.850 00:03:02.860 okay you get more heat exchange that way
00:03:05.400 00:03:05.410 so the boiler coming in identified with
00:03:08.039 00:03:08.049 the red pipe it's going to come into the
00:03:09.750 00:03:09.760 bottom up flow and then out and returned
00:03:12.750 00:03:12.760 to the boiler or to your next heating
00:03:15.180 00:03:15.190 system and what will happen here is the
00:03:18.660 00:03:18.670 reason and how this works is a thermal
00:03:20.940 00:03:20.950 pressure siphon so what happens here is
00:03:23.400 00:03:23.410 this water coming in from the boiler is
00:03:24.960 00:03:24.970 anywhere in the ballpark of 170 to 180
00:03:27.150 00:03:27.160 degrees so it's heating up the water in
00:03:29.100 00:03:29.110 this plate exchanger which is coming in
00:03:30.660 00:03:30.670 roughly 55 degrees
00:03:32.339 00:03:32.349 give or take a couple degrees depending
00:03:33.810 00:03:33.820 on what zip code you're from so the
00:03:35.699 00:03:35.709 water in here is getting hotter and
00:03:37.229 00:03:37.239 hotter and hotter so it's building up
00:03:39.180 00:03:39.190 pressure because when heat when water
00:03:41.490 00:03:41.500 gets heated it expands and of course
00:03:46.050 00:03:46.060 being in this pipe it's building
00:03:47.670 00:03:47.680 pressure because this tank is also
00:03:49.710 00:03:49.720 pressurized that's how it gets water to
00:03:51.690 00:03:51.700 your tap so the water in here is getting
00:03:54.090 00:03:54.100 hotter and hotter in the pressures
00:03:55.259 00:03:55.269 building the tank the water in there is
00:03:59.009 00:03:59.019 naturally cooling that's why it's
00:04:00.240 00:04:00.250 covered with so much insulation so the
00:04:02.129 00:04:02.139 pressure and this is dropping so the
00:04:04.319 00:04:04.329 pressure between this and the water
00:04:06.000 00:04:06.010 jacket in here and the water in here the
00:04:08.640 00:04:08.650 two pressures are going to neutralize
00:04:10.140 00:04:10.150 and when you have that natural
00:04:12.210 00:04:12.220 neutralization the water temperature
00:04:14.340 00:04:14.350 equals out so that's how the thermal
00:04:16.830 00:04:16.840 pressure siphon works if that makes
00:04:18.390 00:04:18.400 sense so once again the water in here
00:04:20.460 00:04:20.470 heats up builds up pressure the water
00:04:22.440 00:04:22.450 here is slowly but surely cooling and
00:04:24.390 00:04:24.400 those two will neutralize at the same
00:04:27.090 00:04:27.100 psi or pressure which is about the same
00:04:29.580 00:04:29.590 temperature you're going to get this
00:04:31.050 00:04:31.060 tank at about 130 degrees with again no
00:04:34.200 00:04:34.210 pump no circulation it's going to use
00:04:36.360 00:04:36.370 the thermal pressure siphon to do it if
00:04:37.890 00:04:37.900 it's installed correctly the most
00:04:39.839 00:04:39.849 important thing is that you've got to
00:04:41.460 00:04:41.470 make sure you
00:04:42.150 00:04:42.160 using a copper a good grade copper on
00:04:44.160 00:04:44.170 the on the domestic hot water side or
00:04:46.170 00:04:46.180 lead-free brass you've got to use these
00:04:49.050 00:04:49.060 things because this is water that's now
00:04:50.640 00:04:50.650 going to be entering your domestic hot
00:04:52.320 00:04:52.330 water system possibly drinking it and
00:04:53.820 00:04:53.830 you're going to be bathing in it so make
00:04:55.320 00:04:55.330 sure you get good quality brass we can
00:04:56.880 00:04:56.890 we have brass and we sell it another
00:04:59.460 00:04:59.470 common question that we get a lot is do
00:05:01.890 00:05:01.900 you heat the domestic hot water first or
00:05:03.960 00:05:03.970 do you heat the boiler first or the hot
00:05:06.060 00:05:06.070 air furnace first the answer is you're
00:05:08.670 00:05:08.680 always going to go to the domestic hot
00:05:10.080 00:05:10.090 water first the reason why is if you're
00:05:12.600 00:05:12.610 taking a shower and you get a couple
00:05:13.830 00:05:13.840 degree difference in your shower you're
00:05:15.480 00:05:15.490 going to know immediately if your wife
00:05:17.250 00:05:17.260 gets it you're going to hear about it so
00:05:18.870 00:05:18.880 make sure you go to the domestic hot
00:05:21.120 00:05:21.130 water first when you go to your boiler
00:05:24.210 00:05:24.220 after this if the temperature house is
00:05:26.220 00:05:26.230 off a degree you won't even notice in
00:05:28.260 00:05:28.270 the hot air system but once you're done
00:05:29.970 00:05:29.980 with the shower and you're taking a lot
00:05:31.320 00:05:31.330 of heat from the the loop from the wood
00:05:33.630 00:05:33.640 boiler or it any contradiction alcoa
00:05:36.540 00:05:36.550 boiler any other boiler system it will
00:05:39.750 00:05:39.760 catch up and get the hot air system so
00:05:42.090 00:05:42.100 I'll back up here and go one more time
00:05:44.160 00:05:44.170 so the water coming in from the wood
00:05:45.570 00:05:45.580 boiler coal furnace boiler any kind of
00:05:48.120 00:05:48.130 boiler system you have with alternative
00:05:49.950 00:05:49.960 energy or any boiler you're going to
00:05:52.740 00:05:52.750 come in you're going to hit the domestic
00:05:54.000 00:05:54.010 hot water first then from there you're
00:05:56.640 00:05:56.650 going to come out and you're going to go
00:05:57.750 00:05:57.760 to your boiler your hot air furnace or
00:06:00.180 00:06:00.190 any other conventional heating system
00:06:01.830 00:06:01.840 you have and then back to your wood coal
00:06:04.740 00:06:04.750 or alternative energy boiler and that's
00:06:07.740 00:06:07.750 really all you have to do that's how
00:06:09.360 00:06:09.370 simple these things are to install and
00:06:11.100 00:06:11.110 the nice thing is this when they're when
00:06:13.320 00:06:13.330 they're not being used the water will
00:06:15.120 00:06:15.130 just throw flow right through your plate
00:06:18.570 00:06:18.580 exchanger into your domestic hot water
00:06:19.860 00:06:19.870 tank and the tank will work as it was
00:06:22.650 00:06:22.660 before it was installed there's nothing
00:06:24.840 00:06:24.850 you need to do the plate exchanger will
00:06:26.820 00:06:26.830 actually heat up the tank a little bit
00:06:28.650 00:06:28.660 warmer than the tank is set for so what
00:06:31.890 00:06:31.900 will happen is the tank will never
00:06:33.360 00:06:33.370 really turn on its coil system only will
00:06:35.760 00:06:35.770 turn on its coil system once you stop
00:06:37.440 00:06:37.450 using your boiler and that applies if
00:06:40.200 00:06:40.210 your boiler is at about 180 degrees if
00:06:43.200 00:06:43.210 you're running a boil a little cooler
00:06:44.280 00:06:44.290 and that the coils inside this might be
00:06:46.500 00:06:46.510 turned on okay but that's all there is
00:06:48.930 00:06:48.940 to it if you have any questions comments
00:06:51.750 00:06:51.760 if you liked the video give me a thumbs
00:06:53.040 00:06:53.050 up at the bottom if you have any
00:06:54.510 00:06:54.520 suggestions or areas
00:06:55.830 00:06:55.840 you don't understand you would like to
00:06:56.939 00:06:56.949 see a video on please make a comment
00:06:58.830 00:06:58.840 below let us know if there's anything
00:07:00.150 00:07:00.160 else we could do to help you and that's
00:07:02.070 00:07:02.080 what we're here for
00:07:02.970 00:07:02.980 check us out alternative heating and
00:07:04.680 00:07:04.690 supplies thank you and have a great day