Boiler Breakdown - What you can check.

WEBVTT
Kind: captions
Language: en

00:00:14.240
when I smothered ivy summer Branford
00:00:16.910 00:00:16.920 living
00:00:17.840 00:00:17.850 and today we're going to look at common
00:00:19.580 00:00:19.590 issues with Fultz on boilers that can
00:00:22.010 00:00:22.020 lead to breakdowns of heating and hot
00:00:23.660 00:00:23.670 water some of these faults might be
00:00:25.970 00:00:25.980 simple everyday occurrences that you
00:00:29.150 00:00:29.160 yourself the customer can put right and
00:00:31.429 00:00:31.439 save yourselves time waiting in or
00:00:35.000 00:00:35.010 phoning us up for a breakdown engineer
00:00:37.400 00:00:37.410 to call in this scenario we have a
00:00:40.460 00:00:40.470 boiler in the airing cupboard and along
00:00:44.210 00:00:44.220 with the timer and the few spur which
00:00:47.119 00:00:47.129 supplies power to the boiler the common
00:00:50.690 00:00:50.700 fault can be that your display on the
00:00:53.779 00:00:53.789 clock or the boiler is completely blank
00:00:56.590 00:00:56.600 which sometimes is because the few spur
00:00:59.720 00:00:59.730 has been accidentally knocked off in
00:01:03.139 00:01:03.149 this scenario in an airing cupboard
00:01:04.760 00:01:04.770 this can sometimes easily be done by
00:01:06.529 00:01:06.539 getting towels in and out of the air and
00:01:08.420 00:01:08.430 covered and you can occasionally catch
00:01:11.900 00:01:11.910 that as you do remove towels or put
00:01:14.150 00:01:14.160 towels in this will then delete lead to
00:01:17.450 00:01:17.460 the display on the timer being
00:01:20.120 00:01:20.130 completely blank same with the boiler
00:01:24.789 00:01:24.799 now you may not know you have done this
00:01:27.440 00:01:27.450 obviously because towels will be up to
00:01:29.870 00:01:29.880 this level so it's always worth finding
00:01:33.109 00:01:33.119 the few spur and just making sure this
00:01:35.510 00:01:35.520 actually turned on in that position you
00:01:41.690 00:01:41.700 might be as simple as that
00:01:43.090 00:01:43.100 but your displays will come back on and
00:01:46.760 00:01:46.770 you'll have heating the hot water again
00:01:49.149 00:01:49.159 these few Spurs are also in the kitchen
00:01:53.929 00:01:53.939 scenario that could be a work surface
00:01:55.969 00:01:55.979 height and occasion then knocked off by
00:01:58.600 00:01:58.610 moving coffee pots or jugs sugar sugar
00:02:02.569 00:02:02.579 pots it can also have been knocked off
00:02:04.730 00:02:04.740 into the off position whose always worth
00:02:06.889 00:02:06.899 checking first and make sure it's on if
00:02:10.310 00:02:10.320 you do find that the few spurt is only
00:02:12.920 00:02:12.930 on position and the display on your
00:02:14.990 00:02:15.000 timer is blank and the display on your
00:02:18.979 00:02:18.989 boiler is blank then you would need to
00:02:21.770 00:02:21.780 give us a call having made sure that
00:02:23.600 00:02:23.610 your timer is on and cooling of the heat
00:02:25.939 00:02:25.949 you also need to check your room stat
00:02:28.099 00:02:28.109 and make sure that hasn't been
00:02:29.580 00:02:29.590 turn down accidentally and he's also
00:02:31.410 00:02:31.420 according to heat here we have it turned
00:02:34.559 00:02:34.569 down below 10 degrees so the heating
00:02:37.350 00:02:37.360 will not come on until we've turned it
00:02:39.330 00:02:39.340 up I'll suggest initially you turn all
00:02:41.670 00:02:41.680 the way up to number 30 and wait and see
00:02:44.160 00:02:44.170 whether your radiators start to heat up
00:02:46.080 00:02:46.090 I've been done that you can then turn
00:02:48.570 00:02:48.580 you back down to a comfortable
00:02:50.640 00:02:50.650 temperature that suit yourself
00:02:53.009 00:02:53.019 usually about 21 another common reason
00:02:56.100 00:02:56.110 for the gas boiler going off is if you
00:02:58.589 00:02:58.599 have a prepayment meet a lot of this one
00:03:00.180 00:03:00.190 here often it can run out of credit and
00:03:02.789 00:03:02.799 you'll need to check this before calling
00:03:04.380 00:03:04.390 aside if you have a gas appliance such
00:03:06.930 00:03:06.940 as a cooker you can always check the
00:03:08.729 00:03:08.739 cooker make sure that's working if not
00:03:11.039 00:03:11.049 you need to go to your meter press the a
00:03:13.979 00:03:13.989 button and follow the on-screen
00:03:16.289 00:03:16.299 instructions and it'll tell you whether
00:03:18.750 00:03:18.760 you have credit or whether the meter is
00:03:20.789 00:03:20.799 off and you need to recreate it if it is
00:03:24.030 00:03:24.040 off you need to get your card insert it
00:03:26.729 00:03:26.739 into the meter and if you have follow
00:03:29.910 00:03:29.920 the on-screen instructions if you have
00:03:32.640 00:03:32.650 no credit on the card obviously you need
00:03:34.860 00:03:34.870 to go to a local top-up points
00:03:38.069 00:03:38.079 re credit your card and then reinsert
00:03:41.580 00:03:41.590 into the meter and add the credit on if
00:03:43.620 00:03:43.630 you followed all these steps and your
00:03:45.180 00:03:45.190 board is still not working or you're
00:03:47.160 00:03:47.170 unsure simply call this number below
00:03:50.360 00:03:50.370 thanks for watching