00:00:02.659 well we got a call for walk around the 00:00:07.07000:00:07.080 floor all kinds of water on the floor 00:00:17.98000:00:17.990 but I ran into this before where someone 00:00:23.26900:00:23.279 has put the drain 00:00:27.42900:00:27.439 inside the Bullard compartment now when 00:00:31.09900:00:31.109 the filter gets clogged up and the 00:00:32.54000:00:32.550 blower can't get any air from anywhere 00:00:34.49000:00:34.500 it sucks the water right out of the 00:00:36.79900:00:36.809 drain that's been going on for years but 00:00:41.51000:00:41.520 also a lot of water damage up here I 00:00:50.29000:00:50.300 don't know if we're leaking water it 00:00:52.79000:00:52.800 looks like we're leaking water from up 00:00:54.83000:00:54.840 here at one time and it was dripping 00:00:58.13000:00:58.140 down damaged a bunch of stuff and I just 00:01:01.72900:01:01.739 kind of looked newer but uh and this is 00:01:07.73000:01:07.740 uh three fifty MeV forty-eight 100 00:01:12.76000:01:12.770 serial code of 3603 so what we'll do now 00:01:19.51000:01:19.520 so we get the camera get this blower 00:01:22.01000:01:22.020 taking out control board taking out in 00:01:24.89000:01:24.900 the trap and we're gonna check the 00:01:28.46000:01:28.470 bottom of heat exchanger 00:01:37.85900:01:37.869 okay I got the blower I'll trap out at 00:01:42.28000:01:42.290 the camera in there one thing I'm seeing 00:01:57.78000:01:57.790 little rust spots over there right there 00:02:22.69000:02:22.700 go rest spots right there so I got to 00:02:31.07000:02:31.080 get back there and see if they're solid 00:02:33.74000:02:33.750 or not I'm gonna get back there and look 00:02:46.09000:02:46.100 notice one more thing in this furnace I 00:02:49.81000:02:49.820 don't know if you can see back here 00:02:54.19000:02:54.200 there's this screw right here that needs 00:02:59.27000:02:59.280 to have a standoff on it when they 00:03:02.66000:03:02.670 replace this inducer motor they forgot 00:03:05.66000:03:05.670 to put all the standoffs back in because 00:03:09.17000:03:09.180 there's a black standoff that goes on 00:03:11.63000:03:11.640 the screw right here that holds them do 00:03:13.61000:03:13.620 sure motor out a certain length or a 00:03:16.25000:03:16.260 certain way and you know they didn't use 00:03:20.78000:03:20.790 them I don't know how this thing sounds 00:03:22.49000:03:22.500 both when we started up okay the rest 00:03:26.03000:03:26.040 but I was talking about was right there 00:03:28.72000:03:28.730 and I'm scratching it it's pretty it's 00:03:37.88000:03:37.890 pretty solid then there's nothing else 00:03:40.94000:03:40.950 here that's rusted or anything so 00:03:45.49000:03:45.500 nothing on the front nothing back there 00:03:49.88000:03:49.890 so the seat exchangers and all right 00:03:53.66000:03:53.670 shape not too bad it's a little dirty so 00:03:57.86000:03:57.870 I made the plate was oh yes annoying 00:04:02.63000:04:02.640 inside the furnace right 00:04:07.53900:04:07.549 so I mean main complaint was water 00:04:11.93000:04:11.940 coming out of the furnace 00:04:20.00000:04:20.010 so they hit the string right here and so 00:04:26.40000:04:26.410 when this filter that's a dangerous 00:04:37.35000:04:37.360 filter cabinet right there holy smokes 00:04:41.71900:04:41.729 the filter is dirty so when the filter 00:04:48.99000:04:49.000 gets dirty it creates a lot of negative 00:04:51.90000:04:51.910 pressure so we pull water out of here 00:04:53.76000:04:53.770 it's not installed right this that drain 00:05:00.17000:05:00.180 where is it so this sits right there I'm 00:05:09.65900:05:09.669 gonna drain coming off the bottom of it 00:05:12.06000:05:12.070 to here so when the filter gets dirty 00:05:15.86000:05:15.870 creates too much negative pressure pulls 00:05:18.12000:05:18.130 water out of the drain that's why we get 00:05:19.86000:05:19.870 all this so that's gotta be repaired but 00:05:26.21000:05:26.220 basically that's it for this one this 00:05:28.44000:05:28.450 was quick heat exchanger inspection I 00:05:30.56000:05:30.570 guess some parts it need to be replaced 00:05:33.33000:05:33.340 like that no ball and then won't run 00:05:38.55000:05:38.560 through it a little more but I think 00:05:40.95000:05:40.960 that's it I think it was just there's my 00:05:43.26000:05:43.270 water problem there guys 00:05:46.77000:05:46.780 - subscribe
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12