00:00:09.260 cain industries manufactures exhaust 00:00:12.08000:00:12.090 heat recovery and steam generator 00:00:13.91000:00:13.920 systems for the boiler economizer 00:00:15.65000:00:15.660 cogeneration and industrial heat 00:00:17.87000:00:17.880 transfer and exchanger markets the 00:00:20.54000:00:20.550 company is located in Germantown 00:00:22.18900:00:22.199 Wisconsin and has been providing exhaust 00:00:24.47000:00:24.480 heat recovery solutions for over 40 00:00:26.72000:00:26.730 years our mission to produce the highest 00:00:29.15000:00:29.160 quality heat recovery products as 00:00:31.18900:00:31.199 resulted in 15 product lines that 00:00:33.44000:00:33.450 consists of more than 3,500 energy 00:00:35.63000:00:35.640 saving models today we will introduce 00:00:37.85000:00:37.860 you to the cogeneration or combined heat 00:00:40.36900:00:40.379 and power product lines our heat 00:00:43.67000:00:43.680 recovery steam generators and exhaust 00:00:45.68000:00:45.690 gas to liquid heat exchangers recover 00:00:47.77900:00:47.789 waste BTU leaving reciprocating engines 00:00:50.29900:00:50.309 gas turbines micro turbine generators 00:00:53.11900:00:53.129 and fuel cells suitable fuel types for 00:00:56.99000:00:57.000 combustion sources include natural gas 00:00:59.36000:00:59.370 propane diesel to heavy fuel oils bio 00:01:02.63000:01:02.640 gas landfill gas digester gas and 00:01:05.78000:01:05.790 gasoline recovered BTUs are transferred 00:01:10.16000:01:10.170 back into steam production or a desired 00:01:12.67900:01:12.689 thermal liquid glycol or water heatsink 00:01:15.70000:01:15.710 tremendous savings result from overall 00:01:18.23000:01:18.240 system efficiency improvements when 00:01:20.03000:01:20.040 recovered energy is repurposed within 00:01:22.52000:01:22.530 the facility and processes the ESG 00:01:26.21000:01:26.220 exhaust steam generator product lines 00:01:28.58000:01:28.590 are unfired and fully automatic they are 00:01:31.85000:01:31.860 skid packaged for economical 00:01:33.46900:01:33.479 installation and customer control 00:01:35.35900:01:35.369 interface integration these waste heat 00:01:37.94000:01:37.950 water-tube boilers produce 99% dry steam 00:01:41.09000:01:41.100 for primary or supplemental steam 00:01:43.46000:01:43.470 operations full steam production is 00:01:45.74000:01:45.750 achieved in less than 10 minutes from a 00:01:47.81000:01:47.820 cold start es g1 models range in 00:01:51.80000:01:51.810 combustion capacity from 600 kilowatts 00:01:54.02000:01:54.030 to 7 megawatts with entering exhaust gas 00:01:56.92900:01:56.939 temperatures from 500 to 1400 degrees 00:01:59.66000:01:59.670 fahrenheit with over 130 models to 00:02:02.48000:02:02.490 choose from unit selection is based on a 00:02:04.78900:02:04.799 50 degree fahrenheit pinch point of an 00:02:06.85900:02:06.869 exhaust gas to saturated steam 00:02:08.66000:02:08.670 temperature ranging from 20 to 350 plus 00:02:11.63000:02:11.640 boiler horsepower 00:02:13.32000:02:13.330 steam generators are stamped under 00:02:14.88000:02:14.890 section 1 of the ASME and National Board 00:02:17.79000:02:17.800 code at an operating steam pressure 00:02:19.47000:02:19.480 range of 3 to 400 pounds per square inch 00:02:21.93000:02:21.940 gauge CRN approvals are available for 00:02:24.90000:02:24.910 all Canadian provinces each ESG 1 00:02:29.97000:02:29.980 includes a modulating exhaust gas bypass 00:02:32.36000:02:32.370 thin tube heat transfer section steam 00:02:35.43000:02:35.440 flash circulating drum assembly full 00:02:37.71000:02:37.720 control system and boiler trim for 00:02:39.60000:02:39.610 complete skid mounted solution Kane 00:02:43.02000:02:43.030 industries exclusive exhaust bypass is 00:02:45.27000:02:45.280 used to modulate exhaust gas flow 00:02:47.03000:02:47.040 depending on steam production 00:02:48.66000:02:48.670 requirements full bypass mode diverts 00:02:51.30000:02:51.310 exhaust gas away from the heat transfer 00:02:53.31000:02:53.320 section the bypass can be configured as 00:02:55.65000:02:55.660 horizontal straight through or a 00:02:57.30000:02:57.310 90-degree vertical exhaust connection 00:02:59.69900:02:59.709 depending on installation requirements 00:03:02.44900:03:02.459 full operating mode directs the exhaust 00:03:05.10000:03:05.110 gas into the heat transfer section 00:03:07.05000:03:07.060 through the modular fin tube racks and 00:03:09.09000:03:09.100 exits back through the bypass the liquid 00:03:13.29000:03:13.300 flow on the Left illustrates exhaust gas 00:03:15.36000:03:15.370 heat being transferred to the water heat 00:03:17.13000:03:17.140 sink flowing through the fin tubes the 00:03:19.38000:03:19.390 other image shows the pump and 00:03:21.09000:03:21.100 circulating system steam is produced 00:03:24.66000:03:24.670 when superheated feed water expands upon 00:03:27.00000:03:27.010 entering the steam flash drum Lance an 00:03:28.89000:03:28.900 elaborate series of baffles and pans 00:03:31.17000:03:31.180 separate the water content from the 00:03:33.39000:03:33.400 steam resulting in 99 percent dry steam 00:03:36.00000:03:36.010 as it enters the main steam system an 00:03:39.05000:03:39.060 optional internal boiler economizer can 00:03:41.82000:03:41.830 be added to further improve system 00:03:43.74000:03:43.750 efficiency boiler feedwater is preheated 00:03:46.56000:03:46.570 before entering the steam flash drum to 00:03:48.57000:03:48.580 recover even more available exhaust gas 00:03:50.79000:03:50.800 BTU the hrs are heat recovery silencer 00:03:55.68000:03:55.690 radio product line is an exhaust gas to 00:03:58.25900:03:58.269 liquid heat exchanger with modulating 00:04:00.50900:04:00.519 exhaust bypass with over 360 pre 00:04:03.63000:04:03.640 designed models to choose from it has 00:04:05.69900:04:05.709 the combustion capacity of 200 kilowatts 00:04:07.97900:04:07.989 to 7 megawatts and accepts entering 00:04:10.83000:04:10.840 exhaust gas temperatures from 300 to 00:04:13.19900:04:13.209 1300 degrees Fahrenheit the hrs are can 00:04:16.53000:04:16.540 be manufactured in a vertical or 00:04:18.27000:04:18.280 horizontal configuration to address 00:04:20.46000:04:20.470 space limitations the packaged hrs are 00:04:24.63000:04:24.640 consists of a thin tube heat transfer 00:04:26.67000:04:26.680 section 00:04:27.18000:04:27.190 and our exclusive modulating exhaust 00:04:29.19000:04:29.200 bypass optional control packages are 00:04:31.62000:04:31.630 available to manage exhaust and liquid 00:04:33.96000:04:33.970 temperatures full exhaust bypass mode 00:04:37.20000:04:37.210 diverts exhaust gas away from the hrs 00:04:39.96000:04:39.970 are depending on system heat load and 00:04:42.00000:04:42.010 liquid outlet temperature requirements 00:04:44.01000:04:44.020 the bypass can be configured as 00:04:46.08000:04:46.09000:04:47.69000:04:47.70000:04:50.04000:04:50.05000:04:52.82000:04:52.83000:04:55.59000:04:55.60000:04:57.39000:04:57.400 passing through the unique single road 00:04:59.55000:04:59.560 design of Finn tubes and back out the 00:05:01.89000:05:01.900 bypass process water synthetic liquid or 00:05:06.51000:05:06.520 a cold water type heat sink flow in the 00:05:08.91000:05:08.920 Finn tubes to recover BTU while cooling 00:05:11.43000:05:11.440 the exhaust gas the UT r1 u-tube 00:05:15.96000:05:15.970 recovery model is a compact exhaust gas 00:05:18.66000:05:18.670 to liquid heat exchanger adapting to 00:05:21.03000:05:21.040 confined areas it has a combustion 00:05:23.01000:05:23.020 capacity to accept 200 250 thousand 00:05:26.22000:05:26.230 standard cubic feet per minute with 00:05:27.81000:05:27.820 entering exhaust gas temperatures up to 00:05:29.58000:05:29.590 1400 degrees Fahrenheit an optional 00:05:32.64000:05:32.650 three-way modulating exhaust diverting 00:05:34.56000:05:34.570 valve can be included if the desired 00:05:37.02000:05:37.030 heatsink cannot accept all exhaust heat 00:05:39.18000:05:39.190 during Operation Kane Industries CHP 00:05:43.40900:05:43.419 product lines are designed for 00:05:45.06000:05:45.070 performance longevity and ease of 00:05:47.58000:05:47.590 maintenance as well as flexibility the 00:05:52.05000:05:52.060 ESG 1 can be used for standalone primary 00:05:55.08000:05:55.090 or supplemental steam demand the hrs are 00:05:59.70000:05:59.710 or UT r1 can be used to capture and 00:06:02.58000:06:02.590 transfer valuable exhaust speed to you 00:06:04.77000:06:04.780 to liquid modular design allows product 00:06:08.97000:06:08.980 lines to be placed in series to 00:06:10.77000:06:10.780 efficiently harvest waste heat the 00:06:12.72000:06:12.730 nature of steam production leaves unused 00:06:14.64000:06:14.650 heat in the exhaust stream from the ESG 00:06:16.68000:06:16.690 1 an hrs are can recover this unused 00:06:20.19000:06:20.200 heat and transfer it to a liquid heat 00:06:22.23000:06:22.240 sink to increase overall system 00:06:24.03000:06:24.040 efficiency unique system demands require 00:06:27.78000:06:27.790 unique solutions Kane Industries has the 00:06:30.65900:06:30.669 innovation and experience to solve your 00:06:33.00000:06:33.010 waste energy recovery challenges 00:06:35.90000:06:35.910 adaptable equipment design and options 00:06:38.37000:06:38.380 overcome installation constraints 00:06:40.74000:06:40.750 find space limitations can be addressed 00:06:42.48000:06:42.490 with lower stance support headers with 00:06:44.97000:06:44.980 welded elbows and extended drain 00:06:47.19000:06:47.200 plumbing split inspection doors can 00:06:49.32000:06:49.330 overcome clearance issues the exhaust 00:06:51.69000:06:51.700 bypass can be constructed as horizontal 00:06:53.91000:06:53.920 straight through or with a vertical 90 00:06:55.92000:06:55.930 degree exhaust outlet cane industry 00:06:59.58000:06:59.590 standard equipment features unmatched 00:07:01.47000:07:01.480 benefits the ESG 1 and hrs our product 00:07:05.34000:07:05.350 lines are typically provided with a 00:07:07.20000:07:07.210 stainless steel exhaust bypass for a 00:07:09.24000:07:09.250 full exhaust flow control full panel 00:07:11.76000:07:11.770 hinged access doors allow easy access 00:07:13.98000:07:13.990 for fin tube inspection and cleaning 00:07:16.07000:07:16.080 individual removable fin tubes or 00:07:18.36000:07:18.370 modular fin tube racks allow for heat 00:07:20.88000:07:20.890 transfer surface repair in the field 00:07:22.92000:07:22.930 Modbus communications provide remote 00:07:25.26000:07:25.270 equipment monitoring and operation 00:07:27.24000:07:27.250 control an optional automatic time suit 00:07:29.73000:07:29.740 blower provides optimum performance when 00:07:31.86000:07:31.870 burning fuels that cause build-up a 00:07:34.19000:07:34.200 knife-edge concentrated air or steam 00:07:36.99000:07:37.000 spray flow pattern is used to blast soot 00:07:39.24000:07:39.250 from Finn tubes into the exhaust stream 00:07:41.22000:07:41.230 and out of the unit 00:07:43.37000:07:43.380 King Industries has CHP applications 00:07:46.40900:07:46.419 installed throughout the world 00:07:47.93000:07:47.940 recovering valuable exhaust gas heat for 00:07:50.55000:07:50.560 liquid transfer and steam generation 00:07:52.71000:07:52.720 from reciprocating engines turbines 00:07:54.90000:07:54.910 micro turbines and fuel cells start 00:07:59.40000:07:59.410 recovering your lost energy today by 00:08:01.50000:08:01.510 visiting the Cain IND comm website and 00:08:04.50000:08:04.510 clicking on the request for quotation or 00:08:06.84000:08:06.850 RFQ link you will answer ten questions 00:08:09.21000:08:09.220 and receive a complete customized 15 00:08:12.09000:08:12.100 page savings analysis study proposal 00:08:14.13000:08:14.140 within 48 hours always feel free to 00:08:16.56000:08:16.570 contact our friendly and knowledgeable 00:08:17.96900:08:17.979 sales engineers during any stage of your 00:08:20.76000:08:20.770 exhaust heat recovery project all of us 00:08:24.33000:08:24.340 at Kane industries appreciate you taking 00:08:26.46000:08:26.470 time to watch this video presentation 00:08:28.29000:08:28.300 and thank you for your interest in Kane 00:08:30.65900:08:30.669 industries exhaust heat recovery 00:08:32.37000:08:32.380 products and innovative solutions 00:08:35.16900:08:35.179 [Music]
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12