Cool Steam Vent Taming - Tutorial nuggets - Oxygen not included

WEBVTT
Kind: captions
Language: en

00:00:00.030
and we're back with a quick tutorial on
00:00:03.439 00:00:03.449 cool steam vents and how to tame them
00:00:05.390 00:00:05.400 now cool steam vents are hmm they're not
00:00:08.030 00:00:08.040 a great source of water but if you're
00:00:10.129 00:00:10.139 stuck and you don't have any other water
00:00:11.720 00:00:11.730 source vents or you're limited on water
00:00:13.610 00:00:13.620 and you need more it can be an option
00:00:15.289 00:00:15.299 simplest thing to do is we are going to
00:00:17.450 00:00:17.460 build a steam turbine heat deletion
00:00:18.950 00:00:18.960 device this will require you to have
00:00:20.779 00:00:20.789 steel though we're going to need a steel
00:00:22.220 00:00:22.230 for the term injector which means you're
00:00:23.450 00:00:23.460 probably going to be waiting till about
00:00:24.679 00:00:24.689 cycle 150 at the earliest
00:00:26.720 00:00:26.730 probably cycle 200 to 250 depending on
00:00:29.419 00:00:29.429 how fast of a player you are I would
00:00:31.820 00:00:31.830 advise you to hold it for steel until
00:00:33.170 00:00:33.180 you do
00:00:33.620 00:00:33.630 AMD's because you can't use ghetto
00:00:35.780 00:00:35.790 setups but normally there you're not
00:00:37.970 00:00:37.980 going to be long-term or permanent or
00:00:39.319 00:00:39.329 things you can depend on for the length
00:00:40.670 00:00:40.680 of the game and a steam turbine heat
00:00:42.799 00:00:42.809 deletion device you just turn it on you
00:00:44.720 00:00:44.730 said it you forget it and you walk away
00:00:46.190 00:00:46.200 and you never have to worry about it
00:00:47.330 00:00:47.340 again now of course I'm going to
00:00:50.029 00:00:50.039 accidentally one of my duplicates if I'm
00:00:51.380 00:00:51.390 not careful well maybe make a few exits
00:00:54.680 00:00:54.690 here so they can get in a net oh one of
00:00:58.819 00:00:58.829 the things you're going to have to worry
00:00:59.689 00:00:59.699 about is temperature transfer steam
00:01:02.090 00:01:02.100 vents if you want to harness Akula steam
00:01:03.889 00:01:03.899 vent there's two ways to go about it
00:01:05.000 00:01:05.010 wouldn't give them a large area to vent
00:01:06.830 00:01:06.840 into now you don't want them over
00:01:08.750 00:01:08.760 pressurizing if it gets to five kilos of
00:01:10.340 00:01:10.350 pressure of steam around them they stop
00:01:11.899 00:01:11.909 venting and you lose steam however I
00:01:13.969 00:01:13.979 don't like to deal with mmm that much I
00:01:16.640 00:01:16.650 don't like to give them that much space
00:01:17.960 00:01:17.970 normally I like to conserve space so
00:01:20.090 00:01:20.100 what we're going to do here is just fill
00:01:21.440 00:01:21.450 this whole area with diamond temperature
00:01:23.030 00:01:23.040 shift late Dimond is pretty cheap in the
00:01:25.670 00:01:25.680 oil biome to be honest though you may
00:01:27.890 00:01:27.900 want to skimp on it later on which case
00:01:29.450 00:01:29.460 you can use a checkerboard pattern you
00:01:30.980 00:01:30.990 know 50/50 split it between Dimond and
00:01:33.710 00:01:33.720 granite you can skimp if you want
00:01:35.569 00:01:35.579 personally I'm just going to go all out
00:01:37.429 00:01:37.439 though realistically you can put back a
00:01:39.380 00:01:39.390 bit the whole point of these temperature
00:01:41.870 00:01:41.880 shift plates is it just means that every
00:01:43.429 00:01:43.439 time the steam comes out it immediately
00:01:45.200 00:01:45.210 will exchange heat with the temperature
00:01:46.460 00:01:46.470 shift plates because they have such high
00:01:48.139 00:01:48.149 thermal conductivity okay that one's not
00:01:50.660 00:01:50.670 finished very very well
00:01:52.039 00:01:52.049 eighty thermal conductivity which means
00:01:53.780 00:01:53.790 the steam olicity exchange heat and
00:01:55.460 00:01:55.470 we're going to have an exchange heat
00:01:56.480 00:01:56.490 with the water down here which will mean
00:01:57.889 00:01:57.899 below the solidification point which
00:02:00.319 00:02:00.329 means the water should or the steam
00:02:01.550 00:02:01.560 should instantly turn into water which
00:02:02.840 00:02:02.850 means we don't get any
00:02:04.340 00:02:04.350 unpleasant overpressurization which
00:02:06.020 00:02:06.030 would lose us water I've also cued up
00:02:08.690 00:02:08.700 another bunch of equipment in here one
00:02:10.460 00:02:10.470 is this gas pump this gas pumps only
00:02:12.080 00:02:12.090 purpose is to vacuum at this area we
00:02:13.820 00:02:13.830 don't want anything but steam in here if
00:02:15.320 00:02:15.330 you leave hydrogen or oxygen in there
00:02:17.750 00:02:17.760 this can have this is a bug where
00:02:19.310 00:02:19.320 sometimes the steam will turn into
00:02:20.480 00:02:20.490 hydrogen or hydrogen and oxygen and it's
00:02:22.130 00:02:22.140 you're not getting water you're getting
00:02:23.420 00:02:23.430 well okay if you wanna make lots of
00:02:24.500 00:02:24.510 hydrogen there's there's a bug way to
00:02:25.820 00:02:25.830 make some it seems but what I like to do
00:02:28.190 00:02:28.200 is just vacuum it out and be done with
00:02:29.390 00:02:29.400 it the liquid pump is to extract the
00:02:31.400 00:02:31.410 excess water so that we don't have too
00:02:32.900 00:02:32.910 much water clogging up the system and
00:02:34.190 00:02:34.200 the temperature sensor is to make sure
00:02:35.630 00:02:35.640 we regulate the temperature in here but
00:02:37.550 00:02:37.560 I'll go over all of this in more detail
00:02:38.870 00:02:38.880 once it's finished we just want to
00:02:40.160 00:02:40.170 complete this and get it up and running
00:02:41.890 00:02:41.900 for that we're just going to stick in a
00:02:43.910 00:02:43.920 thermo regulator we're going to make
00:02:45.140 00:02:45.150 that out of steel this is why I
00:02:46.280 00:02:46.290 recommend you wait until you're you're
00:02:48.440 00:02:48.450 later in the game and you have access to
00:02:49.970 00:02:49.980 this so I cute of all of the piping
00:02:52.970 00:02:52.980 which is going to look rather messy this
00:02:55.430 00:02:55.440 is it will make a lot more sense once
00:02:57.050 00:02:57.060 it's flowing but this cooling loop here
00:02:58.670 00:02:58.680 just goes around cools down the steam
00:03:00.050 00:03:00.060 turbine and then comes down here and
00:03:01.250 00:03:01.260 cools this tiny little icebox we've made
00:03:03.140 00:03:03.150 we're making a small one you don't need
00:03:04.520 00:03:04.530 a large one for a co steam vent the
00:03:07.130 00:03:07.140 output of the steam turbine is going to
00:03:08.390 00:03:08.400 come down here and dump off its liquid
00:03:09.740 00:03:09.750 right there and we put a temperature
00:03:11.030 00:03:11.040 shift plate to help make sure that that
00:03:12.110 00:03:12.120 water converts instantly into steam that
00:03:14.780 00:03:14.790 will all become clear as time goes on
00:03:17.330 00:03:17.340 now I've deleted the steam turbine
00:03:19.190 00:03:19.200 didn't now or canceled the construction
00:03:20.870 00:03:20.880 of it namely because it couldn't be
00:03:22.069 00:03:22.079 built the two squares there we're
00:03:23.539 00:03:23.549 missing so it can't be built all those
00:03:24.560 00:03:24.570 squares are gone and two I knew to put
00:03:26.449 00:03:26.459 some water in here to fill up her icebox
00:03:28.069 00:03:28.079 and I also need to fill up our steam
00:03:29.509 00:03:29.519 room or we're going to have the steam in
00:03:30.590 00:03:30.600 so those two things need to be done
00:03:32.330 00:03:32.340 before the steam turbine can go in place
00:03:33.680 00:03:33.690 but so as we have all the pipes in place
00:03:35.900 00:03:35.910 it doesn't really make a difference
00:03:36.620 00:03:36.630 anyway now this here is all configured
00:03:39.920 00:03:39.930 though I haven't put in power once I put
00:03:41.630 00:03:41.640 power in here I can close this section
00:03:43.220 00:03:43.230 off and we can forget about it
00:03:44.650 00:03:44.660 power connected well okay the power wire
00:03:47.660 00:03:47.670 has been laid in there I just have to
00:03:49.039 00:03:49.049 connect it up to the mains
00:03:49.930 00:03:49.940 now now I'm going to seal this area off
00:03:52.250 00:03:52.260 double layers not really a reason for
00:03:55.940 00:03:55.950 the double layering just the way the
00:03:56.930 00:03:56.940 design work that the everything is
00:03:59.180 00:03:59.190 hooked up all I want to do now is put
00:04:01.430 00:04:01.440 some water in here this is sort of a
00:04:02.600 00:04:02.610 little miniature icebox that's going to
00:04:03.920 00:04:03.930 store some cooling just in case the seam
00:04:06.460 00:04:06.470 Mistico steam vent is going to erupt
00:04:08.180 00:04:08.190 periodically it's nice to have a little
00:04:09.710 00:04:09.720 bit of cooling ready to go when the time
00:04:10.880 00:04:10.890 comes so for coolant here I'm just going
00:04:12.800 00:04:12.810 to use clean water you could use
00:04:14.090 00:04:14.100 polluted water you could use salt water
00:04:15.650 00:04:15.660 brine whatever you want
00:04:16.670 00:04:16.680 I'm just using clean water because it
00:04:18.319 00:04:18.329 happens to be convenient and close by
00:04:19.819 00:04:19.829 and available this little box here is
00:04:22.670 00:04:22.680 going to be our steam room as in this
00:04:24.560 00:04:24.570 equity owner is going to be giving off
00:04:25.969 00:04:25.979 heat as its processed but as it's
00:04:28.070 00:04:28.080 cooling down the water the cooling is
00:04:29.600 00:04:29.610 generating generates heat in this room
00:04:31.040 00:04:31.050 and we will be generating heat in here
00:04:32.480 00:04:32.490 we're here to be destroyed by the steam
00:04:34.070 00:04:34.080 turbine however I want to get rid of all
00:04:37.010 00:04:37.020 the gases that are in here currently
00:04:38.150 00:04:38.160 this room is full of oxygen
00:04:39.820 00:04:39.830 now you could vacuum it out to all sorts
00:04:42.230 00:04:42.240 of fancy things but what I want to do
00:04:44.450 00:04:44.460 it's just something I've discovered
00:04:45.830 00:04:45.840 recently wealth accidentally stumbled
00:04:48.110 00:04:48.120 upon more more more likely it's a very
00:04:50.150 00:04:50.160 simple mechanic that just made it a lot
00:04:51.469 00:04:51.479 easier for me to work with this what I
00:04:52.670 00:04:52.680 used to do was just fill this up with
00:04:54.020 00:04:54.030 over two tons of water once I went to
00:04:56.029 00:04:56.039 above two tons of water the water would
00:04:57.590 00:04:57.600 spread into these upmost tiles and then
00:04:59.719 00:04:59.729 this whole place would be just full of
00:05:00.890 00:05:00.900 clean water and there'll be no gases he
00:05:02.540 00:05:02.550 lied and anymore but I realized if I
00:05:05.480 00:05:05.490 just put in a little layer of polluted
00:05:07.250 00:05:07.260 water or brine or salt water this would
00:05:09.890 00:05:09.900 fill up the bottom layer it only takes
00:05:11.270 00:05:11.280 me 200 kilos of this stuff and then all
00:05:13.250 00:05:13.260 I have to do is just add in some clean
00:05:14.600 00:05:14.610 water or well another water type as well
00:05:17.210 00:05:17.220 and able auto bottle copy those settings
00:05:19.189 00:05:19.199 across you know what we don't need that
00:05:21.500 00:05:21.510 money will just cancel you and this way
00:05:24.140 00:05:24.150 I can fill up this whole area with just
00:05:26.210 00:05:26.220 a small amount of water instead of
00:05:27.800 00:05:27.810 having to put in two tons of water I can
00:05:29.960 00:05:29.970 get away with 400 kilos of water if I
00:05:32.060 00:05:32.070 want or less if you really want to go
00:05:33.740 00:05:33.750 crazy about it and there we go no
00:05:37.939 00:05:37.949 there's something in there polluted
00:05:39.080 00:05:39.090 oxygen yeah it can't be forced air can
00:05:40.969 00:05:40.979 icicle you know what we will make you
00:05:42.770 00:05:42.780 soup only we don't need any more water
00:05:44.180 00:05:44.190 going in there yeah that's an annoyance
00:05:47.990 00:05:48.000 sometimes you'll get that issue where
00:05:49.250 00:05:49.260 gas will clog an area so if we look here
00:05:51.020 00:05:51.030 you'll see there's still gas in there
00:05:52.640 00:05:52.650 but all the rest of this places been
00:05:53.930 00:05:53.940 vacuumed - a simple trick is just to put
00:05:57.020 00:05:57.030 a block in there once the block is in
00:05:59.330 00:05:59.340 there it'll push the gas out and then
00:06:01.189 00:06:01.199 you can replace it with something else
00:06:03.730 00:06:03.740 don't that'll force the gas or destroy
00:06:06.260 00:06:06.270 it and once it's gone we can delete the
00:06:08.089 00:06:08.099 brick and the water should flow in it
00:06:10.550 00:06:10.560 looks like it forced the polluted oxygen
00:06:12.080 00:06:12.090 yet that's fine we'll just deconstruct
00:06:14.000 00:06:14.010 the tile the water should fill it up and
00:06:16.100 00:06:16.110 then we can finish breaking this in once
00:06:18.110 00:06:18.120 it's finished bricked in we can put it
00:06:20.390 00:06:20.400 but a steam turbine on top and then we
00:06:22.189 00:06:22.199 will be ready to just go all my sweeping
00:06:26.270 00:06:26.280 is done placing the steam turbine
00:06:28.250 00:06:28.260 putting him that last brick and I'm
00:06:30.020 00:06:30.030 starting to vacuum out this area which I
00:06:31.610 00:06:31.620 should have done a while ago but you
00:06:32.990 00:06:33.000 know it's this game you keep forgetting
00:06:34.550 00:06:34.560 things it's how all the accidents
00:06:36.560 00:06:36.570 happened now all we need to do is get to
00:06:37.969 00:06:37.979 stand until the place is pretty much a
00:06:39.140 00:06:39.150 vacuum even if there's a tiny bit left
00:06:41.390 00:06:41.400 you can usually get away with this team
00:06:42.860 00:06:42.870 was over right at her once it gets down
00:06:44.300 00:06:44.310 to the milligram section just make sure
00:06:46.189 00:06:46.199 you don't leave it running if the the co
00:06:48.530 00:06:48.540 steam plant starts erupting otherwise
00:06:49.820 00:06:49.830 you'll start pumping steam out of there
00:06:51.170 00:06:51.180 and break some things and I'll just keep
00:06:53.000 00:06:53.010 it forward until this is ready this is
00:06:54.290 00:06:54.300 finished and we're ready to start
00:06:55.400 00:06:55.410 filling up the loop with some some
00:06:57.409 00:06:57.419 polluted water and we're ready to fill
00:07:00.080 00:07:00.090 it up
00:07:00.500 00:07:00.510 now some polluted water already good on
00:07:03.129 00:07:03.139 what we're going to do is turn on this
00:07:05.060 00:07:05.070 liquid pump this liquid pump is set to
00:07:07.250 00:07:07.260 bridge on the water onto our cooling
00:07:09.170 00:07:09.180 loop so this will just keep dumping
00:07:10.820 00:07:10.830 polluted water on until the whole loop
00:07:13.040 00:07:13.050 is full up all the way around so as you
00:07:14.629 00:07:14.639 can see it just goes round goes through
00:07:16.219 00:07:16.229 the equity nur actually other side and
00:07:19.040 00:07:19.050 keeps going and going and going this
00:07:22.850 00:07:22.860 equity nur passes through this pipe
00:07:24.200 00:07:24.210 sensor here this pipe sensor detects if
00:07:26.000 00:07:26.010 the polluted water is above 20 C if it's
00:07:28.219 00:07:28.229 above 20 see it tells the equity owner
00:07:29.629 00:07:29.639 hey this stuff still too too warm turn
00:07:32.089 00:07:32.099 on and start cooling it down some more
00:07:33.370 00:07:33.380 you can see it's coming out here at 30
00:07:35.990 00:07:36.000 40 C and it comes out the other side
00:07:37.670 00:07:37.680 about 14 degrees cooler and it will keep
00:07:39.800 00:07:39.810 doing that and cooling down until this
00:07:41.360 00:07:41.370 box has hit about 20 20 degrees that
00:07:44.360 00:07:44.370 point it should be plenty cool enough to
00:07:45.830 00:07:45.840 keep up with this steam vent timer now
00:07:49.370 00:07:49.380 once that's all full up we'll just turn
00:07:50.930 00:07:50.940 that off don't eat anymore deconstruct
00:07:53.800 00:07:53.810 how does this help us tame the cool
00:07:56.629 00:07:56.639 steam vent well this is acting as a
00:07:58.310 00:07:58.320 cooling box this box is cold it's chill
00:08:01.219 00:08:01.229 and it allows us to dump chill into this
00:08:03.050 00:08:03.060 side of the box
00:08:03.740 00:08:03.750 chew this the steel door the steel door
00:08:07.520 00:08:07.530 dumps chill across when this temperature
00:08:09.110 00:08:09.120 sensor tells it to this temperature
00:08:10.879 00:08:10.889 sensor detects when the temperature in
00:08:12.740 00:08:12.750 here is above 95 degrees and the reason
00:08:15.860 00:08:15.870 it's so high or believing it at 95
00:08:17.480 00:08:17.490 instead of so to say something like 40
00:08:19.040 00:08:19.050 which would seem saner is we don't want
00:08:20.779 00:08:20.789 to cool down the water too much we just
00:08:22.189 00:08:22.199 want to cool down the water enough that
00:08:24.260 00:08:24.270 we can condense it down into water and
00:08:25.790 00:08:25.800 pump it out that's that's it
00:08:28.399 00:08:28.409 this effectively turns it into something
00:08:30.230 00:08:30.240 like a
00:08:31.189 00:08:31.199 saltwater geyser or some of the other
00:08:32.750 00:08:32.760 vents out there that that put water at
00:08:35.089 00:08:35.099 95 seat this does the exact same thing
00:08:36.860 00:08:36.870 pretty much as you can see as this vents
00:08:40.159 00:08:40.169 keep an eye on just coolest inventor
00:08:41.839 00:08:41.849 you'll notice it's an amazing steam and
00:08:44.089 00:08:44.099 at no point is it over pressurize if it
00:08:45.860 00:08:45.870 over pressurizes you're doing it wrong
00:08:47.509 00:08:47.519 you do want it to over pressurize that
00:08:49.430 00:08:49.440 way it's not venting and you're losing
00:08:50.810 00:08:50.820 the water that you could be claiming so
00:08:52.940 00:08:52.950 as this goes along you'll see that this
00:08:54.290 00:08:54.300 here is constantly opening and closing
00:08:56.630 00:08:56.640 the door as the temperature in here
00:08:57.590 00:08:57.600 rises and goes up and down so where is
00:08:59.720 00:08:59.730 it water there's at the bottoms at 95
00:09:01.449 00:09:01.459 you can see the door is engaged and it
00:09:03.769 00:09:03.779 keeps that it keeps the temperature at
00:09:05.689 00:09:05.699 95 when the temperature goes slightly
00:09:07.490 00:09:07.500 above 95 the door engages again and
00:09:09.560 00:09:09.570 starts dumping in temperature from the
00:09:10.759 00:09:10.769 other side this just helps keep the
00:09:13.069 00:09:13.079 whole thing nice and chill and make sure
00:09:14.480 00:09:14.490 that this place is pretty much a vacuum
00:09:15.920 00:09:15.930 constantly if you look in here it's a
00:09:18.230 00:09:18.240 vacuum the moment is team hits the
00:09:20.030 00:09:20.040 temperature shift plates it immediately
00:09:21.199 00:09:21.209 condenses and you can see the drops of
00:09:23.030 00:09:23.040 it they are falling down this allows us
00:09:25.519 00:09:25.529 to instantly condense all the steam nope
00:09:27.230 00:09:27.240 overpressurization and we're only using
00:09:29.060 00:09:29.070 she just barely the correct amount of
00:09:31.009 00:09:31.019 cooling any more cooling then that would
00:09:32.509 00:09:32.519 be a waste and don't adjusted this
00:09:35.900 00:09:35.910 liquid pump here though is the real star
00:09:38.150 00:09:38.160 of the show it detects when the tech
00:09:39.560 00:09:39.570 pressure in here goes above 850 kilos if
00:09:41.750 00:09:41.760 there's more than 850 kilos of pressure
00:09:44.180 00:09:44.190 in this tile we're getting close to that
00:09:45.560 00:09:45.570 point where it's about to form two tiles
00:09:46.790 00:09:46.800 a thousand kilos is when water starts to
00:09:49.550 00:09:49.560 form another tile and if it does that it
00:09:51.319 00:09:51.329 will start blocking the steam vent so
00:09:53.240 00:09:53.250 once it hits 850 kilos of pressure
00:09:54.889 00:09:54.899 there's a liquid foam activates and
00:09:56.540 00:09:56.550 dumps the water out into our storage
00:09:58.009 00:09:58.019 tank which is way over there somewhere
00:10:02.180 00:10:02.190 yeah
00:10:05.010 00:10:05.020 and that's it that's all the system does
00:10:07.530 00:10:07.540 this deletes heat cools down this box
00:10:10.050 00:10:10.060 this box dumps enough chill in here just
00:10:12.180 00:10:12.190 to keep this barely condensing all the
00:10:14.130 00:10:14.140 steam as necessary and then once there's
00:10:16.079 00:10:16.089 too much water in here that water gets
00:10:17.670 00:10:17.680 dumped across the pipe and dumped off
00:10:19.110 00:10:19.120 into our storage tank and that's it a
00:10:22.070 00:10:22.080 couple of things to go over this gas
00:10:24.630 00:10:24.640 pump I just leave it in here you can set
00:10:26.130 00:10:26.140 up liquid locks and stuff to get in and
00:10:27.750 00:10:27.760 out and maybe remove it if you want I
00:10:29.519 00:10:29.529 don't care it's 15 kilos of whatever
00:10:31.889 00:10:31.899 metal you make it out of so I'm okay
00:10:34.440 00:10:34.450 with that you're staying in there I
00:10:35.460 00:10:35.470 would prefer if you made it - I'd have
00:10:36.930 00:10:36.940 cooled amalgam or steel because you're
00:10:38.370 00:10:38.380 not going to be able to get back in
00:10:39.420 00:10:39.430 there and if it gets damaged by the heat
00:10:40.620 00:10:40.630 it will be an annoyance the this year
00:10:45.420 00:10:45.430 I'll just go over exactly how this is
00:10:47.670 00:10:47.680 placed so you can understand why this
00:10:49.290 00:10:49.300 why this works the way it works and why
00:10:51.389 00:10:51.399 we make it this way
00:10:52.639 00:10:52.649 you'll see that the polluted water comes
00:10:55.170 00:10:55.180 in here if it can't get in here and come
00:10:56.880 00:10:56.890 out the other side it will keep rotating
00:10:58.650 00:10:58.660 around the reason for this is very very
00:11:01.290 00:11:01.300 very important it's to do with when the
00:11:03.960 00:11:03.970 coolest team Fanta kugel was inactive so
00:11:06.449 00:11:06.459 we'll do is we will remove this liquid
00:11:07.949 00:11:07.959 bridge actually excuse my debug I'm
00:11:09.990 00:11:10.000 gonna control it for that sucker now you
00:11:14.610 00:11:14.620 see this keeps turning on and off now
00:11:18.720 00:11:18.730 the reason this is bad is the liquid
00:11:20.130 00:11:20.140 stops here so I see this liquid in the
00:11:22.050 00:11:22.060 pipe
00:11:22.410 00:11:22.420 if this what's this go steam vent goes
00:11:24.810 00:11:24.820 dormant the liquid around here will stop
00:11:27.210 00:11:27.220 moving entirely you know what let's say
00:11:28.860 00:11:28.870 stop that entirely now say to me at 50
00:11:31.260 00:11:31.270 it's fine that means that water is just
00:11:34.380 00:11:34.390 going to sit there in the pipe and it's
00:11:37.560 00:11:37.570 12.5 C now but the longer it sits there
00:11:39.840 00:11:39.850 in that steam which is 120 degrees
00:11:41.550 00:11:41.560 around it it will keep heating up and
00:11:43.350 00:11:43.360 heating up and heating up and eventually
00:11:44.639 00:11:44.649 it will get too warm and it will crack
00:11:46.680 00:11:46.690 the pipes so for that reason and that
00:11:49.380 00:11:49.390 reason alone we put in this little
00:11:50.910 00:11:50.920 bridge and that bridge allows the liquid
00:11:52.860 00:11:52.870 to keep constantly flowing whether or
00:11:54.510 00:11:54.520 not the aqua tuner is on or off very
00:11:56.940 00:11:56.950 important to feature this liquid pipe
00:11:59.160 00:11:59.170 thermo sensor is just set up by
00:12:00.480 00:12:00.490 automation to connect to that to detect
00:12:02.100 00:12:02.110 when this is above 20
00:12:05.450 00:12:05.460 this turn ones here is that when the
00:12:08.250 00:12:08.260 temperature is below 95 C we want you to
00:12:11.010 00:12:11.020 open the door and this is here set 2 if
00:12:14.340 00:12:14.350 it's above 850 kilos turn on the liquid
00:12:16.740 00:12:16.750 pump yeah I put those all in one spot so
00:12:18.780 00:12:18.790 I can timestamp that for people who are
00:12:20.190 00:12:20.200 going to need it and that's it that's
00:12:23.070 00:12:23.080 pretty much the most simplistic basic
00:12:25.020 00:12:25.030 set of people that's simplistic but the
00:12:27.180 00:12:27.190 most stable one all you have to do is
00:12:28.890 00:12:28.900 make sure this gets power and so long as
00:12:30.300 00:12:30.310 it has power it will keep churning you
00:12:31.950 00:12:31.960 at water and keep taming that steam vent
00:12:33.480 00:12:33.490 for you for the rest of the game a few
00:12:36.360 00:12:36.370 sigh notes for questions that will come
00:12:38.370 00:12:38.380 up and come up frequently one is do you
00:12:40.920 00:12:40.930 need to make this a complete vacuum some
00:12:42.300 00:12:42.310 people say they've left oxygen in here
00:12:43.560 00:12:43.570 and it doesn't seem to affect the steam
00:12:44.850 00:12:44.860 turbine yes you can probably do that I I
00:12:46.830 00:12:46.840 just don't like to do that if there's a
00:12:48.780 00:12:48.790 blob of oxygen here it usually just
00:12:50.040 00:12:50.050 keeps floating around and blocking the
00:12:51.240 00:12:51.250 vents and that can it just means the
00:12:53.790 00:12:53.800 steam turbine won't work perfectly could
00:12:56.160 00:12:56.170 it cause you a crippling problem
00:12:57.210 00:12:57.220 probably not it's more of a sense of
00:13:00.000 00:13:00.010 completion ISM in my part could you cool
00:13:02.550 00:13:02.560 down the water more than 95 C yes you
00:13:05.010 00:13:05.020 could you could definitely change the
00:13:06.000 00:13:06.010 temperature in this and set it lower
00:13:07.050 00:13:07.060 would you be able to cool it all the way
00:13:08.670 00:13:08.680 down to say 45 degrees or 30 degrees
00:13:10.710 00:13:10.720 probably not your best bet would be to
00:13:13.380 00:13:13.390 just set the temperature here to well as
00:13:15.720 00:13:15.730 low as it will go and set the
00:13:17.190 00:13:17.200 temperature here to as low as it will go
00:13:19.190 00:13:19.200 for low as you can go when it comes to
00:13:21.420 00:13:21.430 polluted water you don't want to
00:13:22.620 00:13:22.630 probably go below about zero degrees and
00:13:24.740 00:13:24.750 also this system is not really designed
00:13:27.000 00:13:27.010 to be optimized for massive amounts of
00:13:29.010 00:13:29.020 cooling it's just designed for cooling
00:13:30.660 00:13:30.670 down a small amount of steam coming out
00:13:32.670 00:13:32.680 of this another question that also comes
00:13:35.070 00:13:35.080 up is what happens if you heat up the
00:13:37.170 00:13:37.180 steam instead of cooling it down and
00:13:38.550 00:13:38.560 running it through a steam turbine that
00:13:40.380 00:13:40.390 is also a very good option but not
00:13:43.710 00:13:43.720 really in theory it sounds great the
00:13:45.630 00:13:45.640 problem is this is emitting steam at
00:13:47.340 00:13:47.350 four kilos per second steam turbines can
00:13:49.590 00:13:49.600 only consume two kilos per second which
00:13:51.360 00:13:51.370 means I would need to clamp two steam
00:13:53.250 00:13:53.260 turbines on top of this just to be able
00:13:54.750 00:13:54.760 keep up with it and not quite I need to
00:13:56.520 00:13:56.530 put on three to be able to keep up with
00:13:57.840 00:13:57.850 it at full capacity even if I could get
00:14:00.780 00:14:00.790 away with just two then I still have to
00:14:03.060 00:14:03.070 make sure that all the steam coming out
00:14:04.200 00:14:04.210 of there hits the correct temperature to
00:14:05.430 00:14:05.440 get soaked up by the steam turbine
00:14:07.050 00:14:07.060 otherwise I'm going to get over
00:14:08.760 00:14:08.770 pressurization and then I'm going to
00:14:09.960 00:14:09.970 lose water it just it's far more
00:14:12.930 00:14:12.940 difficult to heat up the steam 10
00:14:14.730 00:14:14.740 degrees without causing
00:14:15.630 00:14:15.640 overpressurization than it is to just
00:14:17.250 00:14:17.260 cool it
00:14:17.990 00:14:18.000 by like 15 degrees it's harder to heat
00:14:20.990 00:14:21.000 it up by 10 or 15 degrees than it is to
00:14:22.460 00:14:22.470 cool it down by 10 or 15 degrees and
00:14:23.960 00:14:23.970 just pump it up with a one liquid pump
00:14:25.640 00:14:25.650 what this design here can handle a steam
00:14:28.280 00:14:28.290 vent that erupts at up to 10 kilos per
00:14:30.200 00:14:30.210 second the amount of steam to steam
00:14:33.200 00:14:33.210 vents that erupted more than 10 kilos
00:14:34.700 00:14:34.710 per second are exceedingly rare so this
00:14:38.090 00:14:38.100 design will pretty much work on 99% of
00:14:40.460 00:14:40.470 all the steam vents you will encounter
00:14:41.690 00:14:41.700 so you just see a steam vent slap one of
00:14:43.850 00:14:43.860 these on it and get off and continue
00:14:45.620 00:14:45.630 with your day that's it problem solved
00:14:48.700 00:14:48.710 when it comes down to the steam turbine
00:14:50.930 00:14:50.940 up here it might be an idea to insulate
00:14:52.520 00:14:52.530 the room a little bit
00:14:53.660 00:14:53.670 the reason being we're cooling down the
00:14:55.310 00:14:55.320 steam turbine by sending the water up
00:14:58.040 00:14:58.050 here and I'm only using radiant pipes
00:14:59.600 00:14:59.610 made of lead because this device does
00:15:01.730 00:15:01.740 not need super optimized materials that
00:15:04.730 00:15:04.740 cools down the steam turbine to make
00:15:05.930 00:15:05.940 sure it doesn't overheat now there are
00:15:08.090 00:15:08.100 options where people like to use the the
00:15:10.160 00:15:10.170 output water the water coming out of
00:15:12.860 00:15:12.870 here
00:15:13.130 00:15:13.140 the steam turbine itself comes out at 95
00:15:14.930 00:15:14.940 C and you can use that theoretically to
00:15:16.730 00:15:16.740 cool down the steam turbine up to a
00:15:18.140 00:15:18.150 certain amount I just like using that
00:15:20.420 00:15:20.430 myself because then you have to monitor
00:15:21.680 00:15:21.690 carefully when it's on boot-up and make
00:15:23.780 00:15:23.790 sure it doesn't generate too much heat
00:15:25.190 00:15:25.200 if it generates more than if you try and
00:15:27.350 00:15:27.360 dump too much he's into it at that point
00:15:29.030 00:15:29.040 the water won't people to keep up and it
00:15:31.100 00:15:31.110 will over pressurize and then you'll
00:15:32.780 00:15:32.790 have to well jump in some cooling to get
00:15:34.520 00:15:34.530 it working again I prefer to just pay
00:15:36.200 00:15:36.210 the cost and not have to worry about it
00:15:37.640 00:15:37.650 ever breaking on me but considering the
00:15:40.430 00:15:40.440 temperatures jumping into the
00:15:41.570 00:15:41.580 surrounding environment you might want
00:15:43.010 00:15:43.020 to just say break up this area or at
00:15:44.540 00:15:44.550 least break it up on a few sides so that
00:15:45.920 00:15:45.930 it doesn't cause you up doesn't
00:15:47.600 00:15:47.610 interfere with anything around it
00:15:49.150 00:15:49.160 materials wise the only things that are
00:15:51.380 00:15:51.390 really important is the steel for the
00:15:53.180 00:15:53.190 Aqua tuner and the steel for this door
00:15:54.800 00:15:54.810 here they're the only two things that
00:15:56.660 00:15:56.670 really need to be made out of decent
00:15:57.890 00:15:57.900 material as in steel everything else in
00:15:59.840 00:15:59.850 here is pretty much lead so I've got LED
00:16:01.970 00:16:01.980 hydro sensors LED thermal sensors lead
00:16:04.760 00:16:04.770 wires LED everything the reason being
00:16:06.860 00:16:06.870 you don't care the temperatures in here
00:16:10.460 00:16:10.470 are never going to get that high to melt
00:16:12.320 00:16:12.330 late or cause any problems so you can
00:16:13.610 00:16:13.620 pretty much make all the materials in
00:16:14.990 00:16:15.000 here out of anything you want the
00:16:16.610 00:16:16.620 radiant pipes I made them out of lead as
00:16:18.680 00:16:18.690 well well even though lead pipes are
00:16:20.600 00:16:20.610 probably one well they're actually
00:16:22.460 00:16:22.470 pretty good to be honest but you could
00:16:24.230 00:16:24.240 use better materials if you wanted but
00:16:26.030 00:16:26.040 lead was just fine gold copper aluminum
00:16:28.670 00:16:28.680 it really makes no difference pick
00:16:30.020 00:16:30.030 whatever
00:16:30.380 00:16:30.390 materials you want for the radiant pipes
00:16:31.660 00:16:31.670 like I said we're only need to cool to
00:16:33.860 00:16:33.870 stand by a small amount so this whole
00:16:35.360 00:16:35.370 system can be run on basic materials
00:16:37.520 00:16:37.530 except for steel door steel Akwa tuner
00:16:40.540 00:16:40.550 now one last thing to cover what happens
00:16:43.190 00:16:43.200 if you put in too much liquid into your
00:16:44.720 00:16:44.730 cooling loop as you'll see here I've put
00:16:46.430 00:16:46.440 in way too much liquid put in three
00:16:48.770 00:16:48.780 extra blobs and necessary and as the
00:16:50.360 00:16:50.370 whole thing's jammed up and won't spin
00:16:51.680 00:16:51.690 that happened because I plugged in the
00:16:53.720 00:16:53.730 plumbing directly in like this instead
00:16:56.630 00:16:56.640 of plugging the plumbing in with a
00:16:58.670 00:16:58.680 bridge you should really bridge on when
00:17:00.320 00:17:00.330 you're trying to fill up these loops
00:17:01.160 00:17:01.170 otherwise you will over pressurize these
00:17:02.870 00:17:02.880 suckers so you plug it on with a bridge
00:17:05.210 00:17:05.220 the bridge won't allow it to
00:17:06.439 00:17:06.449 overpressurize well in theory I haven't
00:17:08.329 00:17:08.339 had any problems but I haven't really
00:17:10.010 00:17:10.020 stress tested that to the extreme so if
00:17:12.110 00:17:12.120 you do that by accident well the first
00:17:13.730 00:17:13.740 thing you can do is if you do have
00:17:14.600 00:17:14.610 access to a plumber grab the extract
00:17:16.490 00:17:16.500 pipe command and cue them up to extract
00:17:18.680 00:17:18.690 liquids now currently I have control f4
00:17:21.170 00:17:21.180 on so you can see yeah there's still too
00:17:23.720 00:17:23.730 much in there because it's slowly going
00:17:25.280 00:17:25.290 around the place let's grab another one
00:17:27.560 00:17:27.570 right yet no still not good enough it's
00:17:30.050 00:17:30.060 still clogged and grab the third one and
00:17:31.640 00:17:31.650 there we go the whole thing's running
00:17:32.960 00:17:32.970 properly so if you do end up putting too
00:17:34.700 00:17:34.710 much water in just grab a plumber and
00:17:36.140 00:17:36.150 have them remove water or remove clumps
00:17:38.450 00:17:38.460 of water until the system starts running
00:17:40.400 00:17:40.410 again if you don't have access to a
00:17:42.350 00:17:42.360 plumber well in that case delete a pipe
00:17:44.570 00:17:44.580 segment deconstruct the pipe segment to
00:17:46.730 00:17:46.740 drop out a blob of water and then
00:17:48.140 00:17:48.150 replace the pipe segment I've had to do
00:17:49.880 00:17:49.890 that before and you if you've clogged up
00:17:52.190 00:17:52.200 the whole thing just take it three blobs
00:17:53.840 00:17:53.850 to start you're going to need to one
00:17:56.600 00:17:56.610 last thing I swear it's the last one
00:17:58.190 00:17:58.200 temperature shift let's temperature
00:17:59.930 00:17:59.940 shift plates dump piece into all the
00:18:01.700 00:18:01.710 surrounding nine tiles around them
00:18:03.470 00:18:03.480 surrounding eight tiles around them that
00:18:05.930 00:18:05.940 means they agni as well and that means
00:18:07.910 00:18:07.920 it will dump heat into the incident it
00:18:10.250 00:18:10.260 tiles around them which is usually bad
00:18:11.660 00:18:11.670 for example if we look at this year this
00:18:13.160 00:18:13.170 is at 51 see because it's dumping
00:18:14.690 00:18:14.700 temperature from here into that well all
00:18:16.730 00:18:16.740 the rest of the tiles down here are
00:18:17.960 00:18:17.970 Direction about 50 oh yeah they're
00:18:19.550 00:18:19.560 dumping the temperature in from this so
00:18:21.950 00:18:21.960 I've got a temperature shift plate
00:18:22.910 00:18:22.920 they're dumping temperature into that
00:18:24.050 00:18:24.060 and I've got a temperature shift plate
00:18:25.010 00:18:25.020 they're jumping temperature into that
00:18:26.150 00:18:26.160 it's not ideal so you can spread this
00:18:28.520 00:18:28.530 little bit more maybe if you want to
00:18:29.660 00:18:29.670 make it more friendly for temperature
00:18:31.760 00:18:31.770 gain and what you could do over here is
00:18:33.830 00:18:33.840 that they take background buildings you
00:18:35.480 00:18:35.490 could remove those edge ones
00:18:37.980 00:18:37.990 and in theory the whole system should
00:18:39.510 00:18:39.520 still function just fine though I
00:18:41.640 00:18:41.650 haven't tested it so do that at your own
00:18:43.440 00:18:43.450 risk I prefer to sort of make sure
00:18:46.470 00:18:46.480 everything is rock-solid and I never
00:18:47.820 00:18:47.830 have to touch it again it's my preferred
00:18:49.169 00:18:49.179 method of dealing with things anyway
00:18:51.240 00:18:51.250 this should this should take care of
00:18:53.160 00:18:53.170 Annie steam vent you can possibly
00:18:54.690 00:18:54.700 encounter and I hope this works head to
00:18:57.060 00:18:57.070 you and good luck
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12

Phone: +7 343 216 77 75

E-mail: info@lotus1.ru

Sales phone

Russia: +7 343 216 77 75

WhatsApp: +79122710308