CST Distillation Plant - Tray Column Cooling Water SOP
WEBVTT Kind: captions Language: en
00:00:00.110 this video demonstrates how to configure 00:00:02.69000:00:02.700 the cooling water set up for the tray 00:00:04.22000:00:04.230 column with respect to the custom 00:00:05.66000:00:05.670 separations technology distillation 00:00:07.46000:00:07.470 plant and the unit operations laboratory 00:00:09.25900:00:09.269 at Lafayette College the vowels that 00:00:11.62900:00:11.639 operate the cooling water are located on 00:00:13.19000:00:13.200 the right panel of the structure before 00:00:15.16900:00:15.179 the cooling water is turned on the 00:00:16.76000:00:16.770 system must be drained from the previous 00:00:18.29000:00:18.300 operation on the back side of the right 00:00:20.15000:00:20.160 panel open bv 125 and collect the dirty 00:00:23.06000:00:23.070 water in an appropriate collection 00:00:24.50000:00:24.510 container with bv 125 still open 00:00:27.43900:00:27.449 throttle bv 203 the cooling water inlet 00:00:30.34900:00:30.359 three times it does not need to be open 00:00:32.69000:00:32.700 all the way closed bv 125 and empty the 00:00:35.81000:00:35.820 container into the drain behind the 00:00:37.37000:00:37.380 kettle reboiler ensure that bv 125 is 00:00:40.70000:00:40.710 closed before opening bv 203 once the 00:00:44.06000:00:44.070 cooling water supply is completely open 00:00:45.59000:00:45.600 p I 114 should read between 40 and 60 00:00:48.59000:00:48.600 psi P I 114 is located on the back side 00:00:52.22000:00:52.230 of the right panel on the right panel 00:00:56.09000:00:56.100 adjust bv 101 and bv 102 a 00:00:59.86900:00:59.879 counter-current or co-current flow 00:01:01.54900:01:01.559 configuration for the vertical or 00:01:03.88900:01:03.899 horizontal column condensers on the back 00:01:06.41000:01:06.420 panel turn bv 122 to the counter current 00:01:08.96000:01:08.970 position and open bv 120 which sends 00:01:11.45000:01:11.460 cooling water to the distillate product 00:01:13.10000:01:13.110 heat exchanger hex 108 on the right 00:01:16.67000:01:16.680 panel open bv 105 and be v1 02 to 00:01:19.94000:01:19.950 utilize the vertical condenser open bv 00:01:22.76000:01:22.770 106 and bv 103 to utilize the horizontal 00:01:26.21000:01:26.220 condenser ensure that bv 107 and bv 104 00:01:30.05000:01:30.060 are closed to learn more about the 00:01:32.56900:01:32.579 operation of the distillation plant 00:01:34.06900:01:34.079 watch the related videos on the 00:01:35.66000:01:35.670 Lafayette chbe YouTube channel
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12