Custom Air Coolers - Engineered Air-Cooled Heat Exchangers

WEBVTT
Kind: captions
Language: en

00:00:18.170
welcome to custom air coolers here in
00:00:20.320 00:00:20.330 Phoenix Arizona where every industrial
00:00:22.359 00:00:22.369 air cooled heat exchanger we built is
00:00:24.310 00:00:24.320 custom designed and manufactured with
00:00:26.529 00:00:26.539 high quality to meet customers needs I'm
00:00:28.870 00:00:28.880 Rob Holt president and CEO of super
00:00:31.389 00:00:31.399 radiator coils and our custom air
00:00:32.920 00:00:32.930 coolers division our company has more
00:00:35.530 00:00:35.540 than 80 years of history and industrial
00:00:37.299 00:00:37.309 huge range of design and manufacturing
00:00:39.340 00:00:39.350 technology that high-level expertise
00:00:41.920 00:00:41.930 experience goes into every product we
00:00:44.079 00:00:44.089 manufacture custom air pours and we
00:00:46.569 00:00:46.579 produce air cooled heat exchangers for
00:00:48.130 00:00:48.140 all industries here's Kevin Killigrew
00:00:50.500 00:00:50.510 air cooler division manager to tell you
00:00:52.060 00:00:52.070 more air cooled heat exchangers is our
00:00:55.779 00:00:55.789 only business here at customer group and
00:00:57.490 00:00:57.500 as Rob said heat exchanger technology is
00:00:59.979 00:00:59.989 our expertise we serve a broad range of
00:01:02.709 00:01:02.719 markets worldwide including power
00:01:04.689 00:01:04.699 generation oil and gas renewable energy
00:01:07.570 00:01:07.580 chemical processing gas compression
00:01:09.999 00:01:10.009 including natural gas filling stations
00:01:11.710 00:01:11.720 and landfill gas processing oil
00:01:13.540 00:01:13.550 refineries and many other industries
00:01:15.790 00:01:15.800 users of our equipment includes some of
00:01:17.830 00:01:17.840 the biggest names in their respective
00:01:19.270 00:01:19.280 industries including Chevron Siemens
00:01:22.300 00:01:22.310 Waste Management General Electric
00:01:24.910 00:01:24.920 Mitsubishi and dresser ranked during the
00:01:28.149 00:01:28.159 next few minutes we'll show you how we
00:01:29.380 00:01:29.390 custom design and manufacture air cooled
00:01:31.480 00:01:31.490 muted seniors to meet the specifications
00:01:33.429 00:01:33.439 of our many customers at custom air
00:01:36.280 00:01:36.290 cleaners we know that every application
00:01:38.499 00:01:38.509 is different and unique and that means
00:01:40.960 00:01:40.970 beginning the process with detailed
00:01:43.030 00:01:43.040 discussions between the customer and our
00:01:45.100 00:01:45.110 design engineers to clearly define the
00:01:47.319 00:01:47.329 customers needs
00:01:49.290 00:01:49.300 after an order is received our design
00:01:52.530 00:01:52.540 engineers use leading-edge SolidWorks
00:01:54.840 00:01:54.850 software to generate a three-dimensional
00:01:56.700 00:01:56.710 model of the air-cooled heat exchanger
00:01:59.040 00:01:59.050 presenting a visual interpretation for
00:02:01.470 00:02:01.480 the customer's application the digital
00:02:04.170 00:02:04.180 model provides flexibility to make sure
00:02:06.450 00:02:06.460 all interfaces connect properly with the
00:02:08.820 00:02:08.830 customers existing equipment it's the
00:02:11.160 00:02:11.170 next best thing to having the finished
00:02:13.230 00:02:13.240 product upon approval by the customer
00:02:15.870 00:02:15.880 structural materials are ordered
00:02:18.030 00:02:18.040 along with electric motors fans drives
00:02:21.120 00:02:21.130 and other high quality parts most of the
00:02:25.380 00:02:25.390 components for our air coolers are
00:02:27.150 00:02:27.160 fabricated right here in our plan
00:02:34.400 00:02:34.410 metals are cut and shaped in our
00:02:36.590 00:02:36.600 machining Center which has a bed that's
00:02:38.690 00:02:38.700 8 feet wide by 13 feet long and a 3 foot
00:02:42.260 00:02:42.270 bridge clearance the machining Center
00:02:44.810 00:02:44.820 produces high quality headers that
00:02:47.120 00:02:47.130 distribute fluids steam or compressed
00:02:49.460 00:02:49.470 gases through the tubes of air-cooled
00:02:51.680 00:02:51.690 heat exchangers
00:02:56.340 00:02:56.350 steel or copper tubes are welded raised
00:02:59.250 00:02:59.260 or roller expanded into headers then
00:03:02.040 00:03:02.050 lowered into large water tanks for a
00:03:04.200 00:03:04.210 pneumatic leak test if needed the coil
00:03:07.140 00:03:07.150 bundles can also be hydrostatically
00:03:09.030 00:03:09.040 tested up to nine thousand psi next the
00:03:15.300 00:03:15.310 framework and housing for the air cooler
00:03:17.130 00:03:17.140 is assembled and bolted together to
00:03:19.290 00:03:19.300 exacting specifications powerful
00:03:24.510 00:03:24.520 long-lasting electric motors are bolted
00:03:26.940 00:03:26.950 into position fan blades and drive
00:03:30.390 00:03:30.400 systems are assembled and attached to
00:03:32.340 00:03:32.350 the motor
00:03:36.700 00:03:36.710 pumps electrical panels vibration
00:03:39.400 00:03:39.410 switches and pressure gauges are put in
00:03:41.380 00:03:41.390 place then the air-cooled heat exchanger
00:03:44.440 00:03:44.450 is turned on and meticulously tested to
00:03:47.740 00:03:47.750 assure everything meets the performance
00:03:49.960 00:03:49.970 specifications next the new equipment is
00:03:53.890 00:03:53.900 carefully crated and packed for shipment
00:03:56.020 00:03:56.030 to the customer
00:04:01.210 00:04:01.220 our plant has three bridges over the
00:04:03.670 00:04:03.680 shipping Bay and an overhead hoist that
00:04:05.860 00:04:05.870 can lift air coolers measuring up to 70
00:04:08.560 00:04:08.570 feet long and weighing up to 60,000
00:04:11.380 00:04:11.390 pounds custom air coolers is an ISO 9001
00:04:16.150 00:04:16.160 certified company we are also certified
00:04:19.000 00:04:19.010 by the American Society of Mechanical
00:04:20.880 00:04:20.890 Engineers and its National Board the
00:04:23.320 00:04:23.330 Canadian Welding Bureau the Canadian
00:04:25.330 00:04:25.340 registration numbers for fittings and
00:04:27.250 00:04:27.260 pressure vessels and pressure equipment
00:04:29.530 00:04:29.540 directive for European pressure vessels
00:04:31.600 00:04:31.610 through category four besides the North
00:04:34.360 00:04:34.370 American market our custom air coolers
00:04:36.250 00:04:36.260 are used in Australia Dubai South
00:04:38.950 00:04:38.960 America and Saudi Arabia whatever the
00:04:41.320 00:04:41.330 application the location or the
00:04:43.360 00:04:43.370 operating environment custom air coolers
00:04:45.580 00:04:45.590 can design and build the equipment to do
00:04:47.440 00:04:47.450 the job and meet your performance goals
00:04:49.360 00:04:49.370 for many years to come want to know more
00:04:51.610 00:04:51.620 about custom air coolers and how to
00:04:53.200 00:04:53.210 contact us go to our web site at
00:04:57.390 00:04:57.400 www.extracareanimalhospital.net
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12

Phone: +7 343 216 77 75

E-mail: info@lotus1.ru

Sales phone

Russia: +7 343 216 77 75

WhatsApp: +79122710308