Dangerous Gas Boiler A day in the life of a Gas Engineer _ Plumber

WEBVTT
Kind: captions
Language: en

00:00:09.559 --> 00:00:15.000
My name's Allen Hart and today I'm doing
day in the life of a gas engineer so
00:00:15.000 --> 00:00:20.789
being called out to to a Baxi Gas Boiler so
it's been it's been capped off as has
00:00:20.789 --> 00:00:27.180
been unsafe this boat is about two years
old apparently it was installed by
00:00:27.180 --> 00:00:32.489
gas safe registered engineer I'm gonna
have a look at all pipe work I'm gonna
00:00:32.489 --> 00:00:40.590
ring gas safe if just just see what's going
on here so what I'll do now is well have
00:00:40.590 --> 00:00:44.789
a look and I'll show you I'll show you
the faults with this and I'll show you
00:00:44.789 --> 00:00:52.050
the reasons why it's been capped off and
then from that I'll rectify some of the
00:00:52.050 --> 00:00:57.660
issues and then we'll we'll hopefully
get it back up and running again so
00:00:57.660 --> 00:01:00.960
let's have a look now and I'll show you
I'll show you around
00:01:00.960 --> 00:01:08.280
round the boiler so this is a buck seen
gieux attack boiler in my opinion this
00:01:08.280 --> 00:01:13.619
is one of the best boilers of all time
really bulletproof boiler and it just
00:01:13.619 --> 00:01:18.810
does what it says on the tin so if we
have a look underneath with this first
00:01:18.810 --> 00:01:30.750
so we can just see it's been capped off
and then if we have a look the pilot
00:01:30.750 --> 00:01:41.790
just so the boiler was just plugged in
there's no spare from the boiler and
00:01:41.790 --> 00:01:50.220
then everything else all looks all looks
like it's all okay and then if we go
00:01:50.220 --> 00:01:53.270
into this room here
00:01:56.470 --> 00:02:05.240
we're going to hear what conceit flu
goes through but if we have a look
00:02:05.240 --> 00:02:36.920
they've got power of the flu missing so
when we actually look inside this is
00:02:36.920 --> 00:02:51.620
that some it's actually exponent it's
actually that insulation board put just
00:02:51.620 --> 00:03:00.049
to pop it up just to just to start like
hold it up what set this off now I'm
00:03:00.049 --> 00:03:08.570
luck a bit bad so there's no paperwork
for this boiler as such so there's
00:03:08.570 --> 00:03:14.570
there's no benchmark that's so normally
another benchmark booklet and of all the
00:03:14.570 --> 00:03:20.720
readings in of the emissions and and all
the bits and baths for when it was
00:03:20.720 --> 00:03:25.220
installed so there's none of that here
these some paperwork there's a gas
00:03:25.220 --> 00:03:34.760
safety certificate that's dated March
2018 and there's also something here to
00:03:34.760 --> 00:03:41.720
suggest that was fitted on December 2016
I'm gonna ring gas safe up and I'm just
00:03:41.720 --> 00:03:46.700
going to just double check about that
but yeah so so let's have a look let's
00:03:46.700 --> 00:03:53.239
have a look at the boiler I'll take this
flow off and yeah that's gonna look it
00:03:53.239 --> 00:03:58.510
now I've got this flow up now
00:04:17.919 --> 00:04:24.530
so I've obviously got an issue there
with how the flue falls as well it's got
00:04:24.530 --> 00:04:29.600
water water in the flue
so we'll have a look now so I'll just
00:04:29.600 --> 00:04:58.820
pull this I'll just pull this that
actually looks like looks like it is
00:04:58.820 --> 00:05:01.210
long
00:05:16.139 --> 00:05:20.789
so I know that's just loose is that I
00:05:20.819 --> 00:05:33.300
don't know what type of flue that it's
obviously some saw a plume kit a bit more
00:05:43.220 --> 00:05:49.620
so when I'm looking at this that looks
like that is the normal flu because
00:05:49.620 --> 00:05:57.000
that's got the the the Weather ring in
there so if he trips why from outside it
00:05:57.000 --> 00:06:03.060
runs off and it's got the skills in
there and another thing to find out
00:06:03.060 --> 00:06:26.400
where their spins move this so just got
a new flue if you have a look on a new
00:06:26.400 --> 00:06:32.960
flu it's got that ring there and it's
got a spear points there the skill goals
00:06:32.960 --> 00:06:42.110
so I'm wondering if a builder as
checking the end off this end off here
00:06:42.110 --> 00:06:48.569
and then just put some some sort of
plunk it up inside of that and we'll
00:06:48.569 --> 00:06:53.219
it's it's off topic boiler know I'm
gonna tell them you knew this flue just
00:06:53.219 --> 00:07:01.080
so I know this is all salt correct this
part of the flue as you can see from
00:07:01.080 --> 00:07:09.000
there it's all cemented in so this parts
being done installed well if you can pay
00:07:09.000 --> 00:07:11.630
it's that bit
00:07:11.810 --> 00:07:21.300
it seems very different my belief is a
builder has extended this and not the
00:07:21.300 --> 00:07:27.419
original gas engineer I'm still going to
check we got safe and we still got no
00:07:27.419 --> 00:07:32.819
benchmark but customer could have the
the old customer could have taken that
00:07:32.819 --> 00:07:38.360
with them because this is something new
now that lives in this property
00:07:41.340 --> 00:07:50.140
so this looks not too bad any area where
the mid an effort is sealing it with
00:07:50.140 --> 00:07:56.380
some of cement so I'm just gonna remove
this elbow now just one thing I have
00:07:56.380 --> 00:08:03.450
noticed there the flue absolutely falls
away from the boiler so it falls down to
00:08:03.450 --> 00:08:08.830
what would be outside so that's why it's
add water in the flue
00:08:08.830 --> 00:08:15.250
so the flu should always fall back to
the boiler so that's something going out
00:08:15.250 --> 00:08:23.500
way so as I can see now that's just a
standard telescopic flue and this were
00:08:23.500 --> 00:08:31.330
all cemented in really well as I say it
stops them getting out so I'm just gonna
00:08:31.330 --> 00:08:36.250
put the new flow on now these floats
come with some silicon grease and you
00:08:36.250 --> 00:08:41.530
just put something on them seals in
there just so that when you put it on
00:08:41.530 --> 00:08:47.500
the bow you don't put seals out I don't
think to point out as well as this is a
00:08:47.500 --> 00:08:51.610
low profile
elbow on these now and they need to be
00:08:51.610 --> 00:08:57.040
screwed as well the other one wasn't
screwed so I'm slipping the supplier
00:08:57.040 --> 00:09:05.770
than him so we now no need to check that
the new flu is gonna fall back to the
00:09:05.770 --> 00:09:15.850
boiler so about there I'll just need to
wedge that up so I've done the flue part
00:09:15.850 --> 00:09:20.800
of this now so I'm going to connect the
gas back up and then I'm gonna test the
00:09:20.800 --> 00:09:28.260
gas so just just get this oh yeah a
virus like enough
00:09:42.600 --> 00:09:47.890
and then people attack that up and I'm
gonna go put a test on gas so just blood
00:09:47.890 --> 00:09:54.460
tests on gases now so I've got my Titan
test I know we have some mixed feedback
00:09:54.460 --> 00:10:29.380
on that and I thought became a miser
where they work in because I'm gonna
00:10:29.380 --> 00:10:43.270
print it out as well just to prove this
is right so I'll come back to you in a
00:10:43.270 --> 00:10:48.630
few minutes so as we know we've got a
farm and it tests
00:10:48.630 --> 00:10:55.090
so it just tested a lot by now we're
doing a minute sterilization and then
00:10:55.090 --> 00:11:00.790
we've got two minutes for the test
so just got about eight seconds left on
00:11:00.790 --> 00:11:06.310
this test
yeah and we can see that it's not drops
00:11:06.310 --> 00:11:12.120
oh so I'm just going to print out
00:11:20.709 --> 00:11:27.410
I'm also going to get at this now this
file is a particular boiler and it's
00:11:27.410 --> 00:11:32.930
quite far away and so we're done with
coda and the gas is 22 mm so I do
00:11:32.930 --> 00:11:37.040
suspect they will be under gassed so I'm
just going to go fire the boiler room
00:11:37.040 --> 00:11:50.200
and so I'll just turn this stick it off
set the burner on so to put this into
00:11:50.200 --> 00:11:57.310
commissioning mode our service mod you
just put on so they're just come back
00:11:57.310 --> 00:12:03.080
and I'll go into service mode so that
service mud on high and then you can set
00:12:03.080 --> 00:12:09.230
it down to just one thing
well you're doing this if you run the
00:12:09.230 --> 00:12:18.380
hot tub then you'll stay in service mode
longer got an app on before and I'm just
00:12:18.380 --> 00:12:32.380
gonna put the reading in so it's 101 101
warm 3.38
00:12:36.790 --> 00:12:42.870
so start now and I'll just come back to
you in a few minutes
00:12:42.870 --> 00:12:49.360
so I'll just don't gas off when it's at
five or four or five so we said five
00:12:49.360 --> 00:13:04.360
four five so we can calculate right now
and it's given is faithful so I can say
00:13:04.360 --> 00:13:13.590
it's definitely under guests I'm gonna
test this now with the analyzer test the
00:13:13.590 --> 00:13:18.370
pressure
one thing to point out here we have a
00:13:18.370 --> 00:13:23.980
lot could be pressure gauge that was at
one bar now this is a big heating system
00:13:23.980 --> 00:13:28.210
and it's only got the expansion vessel
that's in the boiler
00:13:28.210 --> 00:13:34.060
so clearly the expansion vessel is under
sized for this system so that's also
00:13:34.060 --> 00:13:41.010
something something that we'll have to
set a customer to advise to
00:13:41.230 --> 00:13:48.500
so the emissions are flying on high law
unscrew swap but now reject the inlet to
00:13:48.500 --> 00:13:52.399
make sure that that's okay as well
00:13:52.399 --> 00:14:00.050
so the admin my spy so pressure gears
has gone our way round to free now as
00:14:00.050 --> 00:14:07.309
the system has got well so definitely it
definitely needs an expansion vessel an
00:14:07.309 --> 00:14:15.050
additional expansion vessel fitted I've
just called box a and box a have
00:14:15.050 --> 00:14:22.189
confirmed that the boiler has not been
registered a bank phone gas safe and gas
00:14:22.189 --> 00:14:28.879
safe also confirmed that the boiler
hasn't been registered so it seems like
00:14:28.879 --> 00:14:35.269
it wasn't installed by gas if engineer I
don't know the jury's out I have got
00:14:35.269 --> 00:14:41.959
some information here which says
certificate of installation and it says
00:14:41.959 --> 00:14:47.059
that the boiler has been installed as
per manufacturer's instructions and
00:14:47.059 --> 00:14:52.189
complies with building regulations
installed ain't commissioned and it says
00:14:52.189 --> 00:14:57.889
the name and it's signed so that of
customer looking at that would would
00:14:57.889 --> 00:15:04.819
feel that it's been being done correctly
so what's gonna happen next is this this
00:15:04.819 --> 00:15:15.079
is gonna be required to gas safe and gas
it can do some investigations and see so
00:15:15.079 --> 00:15:19.399
yeah so I love a lot I'll show you I'll
show you at rest of what I've done a
00:15:19.399 --> 00:15:25.670
half shot I'll show your flue and then
we'll finish up really so you have to
00:15:25.670 --> 00:15:30.439
always make sure that you use a gas safe
registered engineer and if you're gonna
00:15:30.439 --> 00:15:35.809
buy a property it is very easy just a
phone gas surf up and just ask them if
00:15:35.809 --> 00:15:41.980
the boiler that's been installed has
been registered so don't rely on
00:15:41.980 --> 00:15:47.809
certificates the solicitor gives you
actually for gas if and then they will
00:15:47.809 --> 00:15:53.209
tell you whether or not it has as I said
the customers got a few different sort
00:15:53.209 --> 00:15:57.670
certificates here that would suggest
that it's been installed
00:15:57.670 --> 00:16:01.850
they said Binney stock correctly it says
it's been installed some manufacturer
00:16:01.850 --> 00:16:07.100
instructions and it hasn't
there's quite a few quite a few reasons
00:16:07.100 --> 00:16:11.990
it hasn't so the gas is under sized
the blow off the PRV doesn't go to
00:16:11.990 --> 00:16:19.160
outside the flue was incorrect also
there's no controls on it so it's just
00:16:19.160 --> 00:16:27.800
enough for later hasn't even got time or
anything to control it so clearly it
00:16:27.800 --> 00:16:32.629
hasn't been a very you know a very good
install but well have a look at rest of
00:16:32.629 --> 00:16:41.959
it now just a block up flue and yeah so
I'm just gonna check the water flow on
00:16:41.959 --> 00:16:47.660
this just to see if it was the right
size boiler for this process I would
00:16:47.660 --> 00:16:50.800
never insult viola
00:16:55.970 --> 00:17:01.119
so we've got about 10 litres a minute on
hot water
00:17:08.310 --> 00:17:16.800
I've got about 10 litres a minute at
Cold War so we could about a 25 kilowatt
00:17:16.800 --> 00:17:27.740
hour 28 kilowatt boiler and it's got 10
litres a minute I'm cold
00:17:27.740 --> 00:17:35.910
this boy Lord really you need to have at
least 18 19 litres a minute on your cold
00:17:35.910 --> 00:17:42.770
water so so the boiler will work to its
full potential this boiler is far far
00:17:42.770 --> 00:17:49.920
too big for his property you don't need
a five kilowatt boiler for 10 litres a
00:17:49.920 --> 00:17:53.520
minute
it's just madness the other thing as
00:17:53.520 --> 00:18:00.990
well the the gas wouldn't have needed to
be so big if if right-size boiler so
00:18:00.990 --> 00:18:06.390
that could have fitted a 24 on a 28
kilowatt boiler in this property and it
00:18:06.390 --> 00:18:11.330
would have just done just as good in
fact it probably being slightly better
00:18:11.330 --> 00:18:19.680
so yeah it's just it's just crazy really
right okay so let's all rest of stuff
00:18:19.680 --> 00:18:28.920
now so that's the flue outside all don't
know so I can see the pressure has gone
00:18:28.920 --> 00:18:37.160
above free bar now if we have a look
here we can just see a bit of water
00:18:37.160 --> 00:18:44.100
thanks running down from the inside in
the house so I just need to wipe that
00:18:44.100 --> 00:18:52.400
flew off so sealed it inside and outside
and what you need a bit filler
00:18:54.440 --> 00:19:00.110
I've only had time to deal the flu today
I'm gonna make some recommendations for
00:19:00.110 --> 00:19:03.049
the customer so the gas needs to be
updated
00:19:03.049 --> 00:19:08.900
it needs the blow-off the PRV chicken
that needs to be taken to outside
00:19:08.900 --> 00:19:15.200
it needs a remor expansion vessel fee as
well also it's got some radio valves
00:19:15.200 --> 00:19:23.210
that's they're leaking so they will need
they need replacing so yeah I uh puff I
00:19:23.210 --> 00:19:27.500
hope I've not missed out out that I
wanted to put in a hour but if you've
00:19:27.500 --> 00:19:32.780
got any questions please please ask them
in comments below and thank you for
00:19:32.780 --> 00:19:37.990
taking the time to watch to watch this
video thanks very much