Direct Fired Vaporizer

WEBVTT
Kind: captions
Language: en

00:00:22.160
our D f-series direct fired vaporizer
00:00:25.029 00:00:25.039 was first patented in 1932 it remains
00:00:28.240 00:00:28.250 today the most commonly used vaporizer
00:00:30.580 00:00:30.590 in the world it's simple economical and
00:00:33.220 00:00:33.230 easy to install when an application
00:00:35.680 00:00:35.690 lacks electricity or requires
00:00:37.600 00:00:37.610 portability the DF series vaporizer can
00:00:40.630 00:00:40.640 be an ideal solution common applications
00:00:43.420 00:00:43.430 include temporary heating at
00:00:44.979 00:00:44.989 construction sites animal confinement
00:00:47.610 00:00:47.620 agriculture and orchard heating and crop
00:00:50.290 00:00:50.300 drying DF series direct fired vaporizers
00:00:53.619 00:00:53.629 apply heat directly to a pressure vessel
00:00:55.810 00:00:55.820 containing liquid lpg the heating
00:00:58.720 00:00:58.730 process induces vaporization while the
00:01:01.479 00:01:01.489 burner consumes a small amount of the
00:01:03.459 00:01:03.469 vapor being generated DF series
00:01:06.070 00:01:06.080 vaporizers guarantee a continuous supply
00:01:08.650 00:01:08.660 of vapor will be available for your
00:01:10.779 00:01:10.789 application there are four DF series
00:01:13.900 00:01:13.910 models the 40 40 the 80 40 the 120 60
00:01:17.950 00:01:17.960 and the 1 6 th these models are combined
00:01:21.639 00:01:21.649 in multiples when large capacities are
00:01:23.950 00:01:23.960 required all gas SDI vaporizers are
00:01:27.130 00:01:27.140 built tough a rugged heavy gauge metal
00:01:29.830 00:01:29.840 enclosure with powder coat applied over
00:01:32.260 00:01:32.270 zinc plating protects against harsh
00:01:34.180 00:01:34.190 environments access to the internals of
00:01:37.059 00:01:37.069 the 40/40 80 40 and 126th evei per eyes
00:01:40.630 00:01:40.640 errs is provided via a latch 'less door
00:01:43.120 00:01:43.130 panel the 1 6 th and larger models
00:01:46.059 00:01:46.069 utilize a slightly different door
00:01:47.919 00:01:47.929 however both designs allow easy removal
00:01:50.949 00:01:50.959 of the vaporizer burner if required on
00:01:53.290 00:01:53.300 models smaller than the 1 6 th hour
00:01:55.900 00:01:55.910 domed exhaust top combined with our
00:01:58.240 00:01:58.250 unique flue collar design prevents rain
00:02:00.699 00:02:00.709 infiltration into the burner but 1 6 th
00:02:03.279 00:02:03.289 and larger models are equally protected
00:02:05.529 00:02:05.539 with a highly effective rain resistant
00:02:08.050 00:02:08.060 combustion stack this cutaway is a
00:02:10.300 00:02:10.310 typical 4040 model the exhaust flue
00:02:13.240 00:02:13.250 shrouds the heat exchanger and transfers
00:02:15.400 00:02:15.410 combustion gases to the exhaust stack
00:02:17.530 00:02:17.540 its stainless steel construction
00:02:19.960 00:02:19.970 eliminates corrosion and extends the
00:02:22.300 00:02:22.310 vaporizer service life during operation
00:02:25.030 00:02:25.040 a mechanical ball float acts as a safety
00:02:27.400 00:02:27.410 to prevent the passing of liquid
00:02:29.350 00:02:29.360 unvailed lpg downstream stainless steel
00:02:32.770 00:02:32.780 to
00:02:33.200 00:02:33.210 minimizes potential clogging of the
00:02:35.150 00:02:35.160 temperature controller and burner
00:02:36.740 00:02:36.750 orifices it should be noted that some
00:02:39.560 00:02:39.570 copper tubing is still used on the 1 6
00:02:41.960 00:02:41.970 th and larger models all gas SDI
00:02:45.350 00:02:45.360 provides an automatic 9 volt DC reignite
00:02:48.500 00:02:48.510 er as standard on all models when
00:02:50.870 00:02:50.880 service requires replacement of the re
00:02:52.940 00:02:52.950 igniter spade connectors make the field
00:02:55.370 00:02:55.380 change simple removal of the 9 volt DC
00:02:58.280 00:02:58.290 battery allows the end user to disable
00:03:00.800 00:03:00.810 the reignite er if desired
00:03:02.570 00:03:02.580 all all gas SDI direct fired vaporizers
00:03:05.630 00:03:05.640 carry asme ul and CRM approvals the 40
00:03:10.010 00:03:10.020 40 and 80 40 models also carry the CE II
00:03:13.130 00:03:13.140 and PE D marks of DET norske veritas
00:03:15.800 00:03:15.810 better known as DN b over 80 years after
00:03:20.180 00:03:20.190 our founding we still lead our industry
00:03:22.460 00:03:22.470 and safety and quality we differentiate
00:03:25.070 00:03:25.080 ourselves from the others by our
00:03:26.630 00:03:26.640 unwavering commitment to both innovation
00:03:29.120 00:03:29.130 and purpose our products allow
00:03:31.790 00:03:31.800 businesses located off the natural gas
00:03:33.950 00:03:33.960 grid or under grid curtailment to
00:03:36.260 00:03:36.270 operate we eliminate downtime due to gas
00:03:39.350 00:03:39.360 supply problems ensuring people can work
00:03:42.080 00:03:42.090 and goods and services will flow to
00:03:44.180 00:03:44.190 market at all gas SDI
00:03:46.700 00:03:46.710 our goal is to make you a customer for
00:03:49.670 00:03:49.680 life
00:04:03.160 00:04:03.170 you
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12

Phone: +7 343 216 77 75

E-mail: info@lotus1.ru

Sales phone

Russia: +7 343 216 77 75

WhatsApp: +79122710308