00:00:01.300 [Music] 00:00:11.08000:00:11.090 here you have n cons 165 gallon per hour 00:00:15.82000:00:15.830 natural gas-fired evaporator from this 00:00:19.60900:00:19.619 view you can see the control panel the 00:00:22.49000:00:22.500 system is configured with auto fill 00:00:25.46000:00:25.470 control and also auto dump you can see 00:00:28.88000:00:28.890 on the bottom right of the system is an 00:00:30.71000:00:30.720 auto dump valve the system has a mist 00:00:35.51000:00:35.520 illumination system consisting of two 00:00:37.93000:00:37.940 mist pads and is also set on a skid now 00:00:44.95900:00:44.969 we're going to walk around the system 00:00:47.09000:00:47.100 and I'll just comment on some of the the 00:00:49.76000:00:49.770 features that you can see in the view 00:00:52.18000:00:52.190 the very top of the unit is an integral 00:00:55.36900:00:55.379 exhaust blower going down from there 00:00:59.51000:00:59.520 from the top down on the side you'll see 00:01:02.47900:01:02.489 a high level shutoff an operating level 00:01:06.05000:01:06.060 probe a low level shutoff a thermocouple 00:01:10.01000:01:10.020 to monitor the temperature of the liquid 00:01:12.28900:01:12.299 a low level for controlling the auto 00:01:17.06000:01:17.070 dump feature and again the auto dump 00:01:20.09000:01:20.100 valve 00:01:22.53000:01:22.540 [Applause] 00:01:32.00000:01:32.010 continuing to the backside on on the 00:01:34.64900:01:34.659 left-hand side of the unit you'll see 00:01:36.30000:01:36.310 the ox panel that is where the 00:01:38.21000:01:38.220 electrical power will come in you have a 00:01:41.21000:01:41.220 VFD on this system for the exhaust 00:01:44.60900:01:44.619 blower motor and a transformer on the 00:01:48.63000:01:48.640 top of the lid near the back is the 00:01:52.35000:01:52.360 inlet for wastewater 00:02:15.07000:02:15.080 this side of the system from left to 00:02:18.05000:02:18.060 right is an a gas-fired burner with a 00:02:23.63000:02:23.640 shroud in the middle you've you've got 00:02:27.08000:02:27.090 the chimney for exhaust gases combustion 00:02:31.61000:02:31.620 gases and on the right you've got a 00:02:34.10000:02:34.110 burner without the shroud these burners 00:02:36.65000:02:36.660 are forced draught combustion burners 00:02:39.47000:02:39.480 and they can be monitored or tuned from 00:02:45.14000:02:45.150 the chimney using those two small prongs 00:02:49.16000:02:49.170 that you see coming out of the chimney 00:02:51.52000:02:51.530 they're tuned independently and then 00:02:54.17000:02:54.180 they can run together after that the 00:02:58.99000:02:59.000 middle probe there is a thermocouple 00:03:02.00000:03:02.010 that will be a shutdown condition at 00:03:04.16000:03:04.170 high temperature 00:03:09.84000:03:09.85000:03:13.24000:03:13.250 and that is your 165 gallon per hour and 00:03:17.35000:03:17.360 con thermal evaporator
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12