FrontLine Automatic Plate Heat Exchanger

WEBVTT
Kind: captions
Language: en

00:00:02.100
[Music]
00:00:05.349 00:00:05.359 front 15 is the largest hygienic plate
00:00:09.200 00:00:09.210 heat exchanger on the market it has been
00:00:12.860 00:00:12.870 developed to meet the high capacity
00:00:14.780 00:00:14.790 demands required by today's super-sized
00:00:17.630 00:00:17.640 dairies front 15 can pass your eyes up
00:00:21.769 00:00:21.779 to 600 GPM of cheese milk per hour and
00:00:25.279 00:00:25.289 still be cost-efficient for flow rates
00:00:28.310 00:00:28.320 as low as 150 G p.m. depending on
00:00:31.730 00:00:31.740 regeneration Alfa Laval has further
00:00:35.299 00:00:35.309 developed this unit to include a frame
00:00:37.790 00:00:37.800 with an automatic opening and closing
00:00:40.520 00:00:40.530 feature the PLC based control system
00:00:43.520 00:00:43.530 features a programmable interface the
00:00:46.279 00:00:46.289 system is based on standard
00:00:48.080 00:00:48.090 allen-bradley rockwell components the
00:00:50.479 00:00:50.489 unit is controlled from the logic menus
00:00:52.819 00:00:52.829 on the touch screen and can easily be
00:00:55.130 00:00:55.140 reconfigured for new plate combinations
00:00:58.750 00:00:58.760 replacing a plate in the heat exchanger
00:01:00.709 00:01:00.719 is a simple process when the screw nuts
00:01:04.219 00:01:04.229 are loosened the bolt can be lifted out
00:01:06.590 00:01:06.600 leaving plenty of room for removal of
00:01:08.960 00:01:08.970 the channel plate the design makes it
00:01:11.750 00:01:11.760 easy to dismount the nuts and they can
00:01:14.240 00:01:14.250 only be remounted in one position to
00:01:16.880 00:01:16.890 guarantee the synchronization between
00:01:18.980 00:01:18.990 the bolts
00:01:19.820 00:01:19.830 00:01:23.540 00:01:23.550 the front 15 has very high opening and
00:01:27.390 00:01:27.400 closing speed the unit allows access to
00:01:30.270 00:01:30.280 the plates in three minutes
00:01:32.220 00:01:32.230 the heat transfer area of the channel
00:01:34.830 00:01:34.840 plates is 10 square feet for each plate
00:01:37.830 00:01:37.840 the large plate size means higher heat
00:01:40.890 00:01:40.900 recovery the benefit from this is more
00:01:43.680 00:01:43.690 energy savings available in a single
00:01:46.020 00:01:46.030 frame for example 570 GPM pasteurizing
00:01:50.370 00:01:50.380 at 92 percent heat recovery the top and
00:01:54.900 00:01:54.910 bottom bolts are positioned to allow for
00:01:57.240 00:01:57.250 double corners at the connection plates
00:01:59.540 00:01:59.550 the open nut has a very innovative
00:02:02.400 00:02:02.410 design fulfilling applicable 3a
00:02:05.480 00:02:05.490 recommendations with a minimum of
00:02:08.010 00:02:08.020 details it is easy to inspect and clean
00:02:10.880 00:02:10.890 the completely open design has wide
00:02:14.040 00:02:14.050 clearances between all surfaces and does
00:02:16.770 00:02:16.780 not need any seals which can create dirt
00:02:19.410 00:02:19.420 traps the pressure plate and the frame
00:02:23.010 00:02:23.020 plate have been designed with sloped
00:02:24.960 00:02:24.970 surfaces for high cleanability no access
00:02:28.830 00:02:28.840 to internal bearings or support
00:02:31.050 00:02:31.060 structure is required along both sides
00:02:33.960 00:02:33.970 of the frame aligned safety switch is
00:02:36.810 00:02:36.820 installed which allows the operator to
00:02:39.060 00:02:39.070 stop the movement from any position
00:02:40.920 00:02:40.930 which is crucial when working alone the
00:02:44.460 00:02:44.470 unit has been designed to fulfill see
00:02:46.770 00:02:46.780 safety regulations to be able to start
00:02:49.710 00:02:49.720 the drive unit a key switch has to be
00:02:52.199 00:02:52.209 turned to avoid non-authorized personnel
00:02:54.479 00:02:54.489 from opening the unit
00:02:56.520 00:02:56.530 additionally the control system monitors
00:02:59.100 00:02:59.110 both torque and speed and interrupts the
00:03:01.830 00:03:01.840 movement the full six inch porting size
00:03:05.190 00:03:05.200 makes it possible to run at high
00:03:07.140 00:03:07.150 capacities for example up to 1200 GPM
00:03:10.740 00:03:10.750 cheese milk pasteurized three sizes of
00:03:14.130 00:03:14.140 frame lengths include 700 550 or 375
00:03:18.900 00:03:18.910 pieces of plates this corresponds to
00:03:22.170 00:03:22.180 twenty sixteen point five and thirteen
00:03:25.350 00:03:25.360 feet the quality construction of the
00:03:27.810 00:03:27.820 heavy-duty carrying bars prevent sagging
00:03:30.620 00:03:30.630 compared to other plate heat exchangers
00:03:33.390 00:03:33.400 the front 15 saves space because of the
00:03:36.540 00:03:36.550 smaller footprint
00:03:41.330 00:03:41.340 the front 15 key benefits are easy
00:03:45.050 00:03:45.060 access fully automatic
00:03:47.750 00:03:47.760 opening and closing device reduces time
00:03:50.330 00:03:50.340 on service which means lower service
00:03:52.760 00:03:52.770 cost innovative design the design of the
00:03:56.720 00:03:56.730 drive unit is based on a few easily
00:03:59.059 00:03:59.069 available standard components which
00:04:01.190 00:04:01.200 means reduced amount of spare parts fast
00:04:04.160 00:04:04.170 speed the heat exchanger has very high
00:04:07.339 00:04:07.349 opening and closing speed at low noise
00:04:10.040 00:04:10.050 level the unit allows access to the
00:04:12.620 00:04:12.630 plates in three minutes which means the
00:04:14.900 00:04:14.910 lower service cost high performance the
00:04:20.360 00:04:20.370 full six inch porting size makes it
00:04:22.730 00:04:22.740 possible to run at high capacity for
00:04:25.250 00:04:25.260 example up to 1200 GPM cheese milk
00:04:28.400 00:04:28.410 pasteurized this high flow rate capacity
00:04:31.040 00:04:31.050 means lower investment costs since one
00:04:34.129 00:04:34.139 unit can replace two units energy
00:04:37.909 00:04:37.919 savings the large heat transfer plate of
00:04:41.000 00:04:41.010 ten square feet each means maximum area
00:04:43.879 00:04:43.889 of seven thousand square feet this large
00:04:47.120 00:04:47.130 plate size means higher heat recovery
00:04:49.730 00:04:49.740 the benefit from this is more energy
00:04:52.310 00:04:52.320 savings in a single frame small
00:04:56.330 00:04:56.340 footprint compared to other heat
00:04:58.670 00:04:58.680 exchangers the front 15 saves space
00:05:01.460 00:05:01.470 because of the smaller footprint the
00:05:04.310 00:05:04.320 benefit of this is lower installation
00:05:06.890 00:05:06.900 cost Alfa Laval is at the forefront of
00:05:11.719 00:05:11.729 R&D and continues to improve and develop
00:05:14.900 00:05:14.910 products to optimize our customers
00:05:17.719 00:05:17.729 processes
00:05:19.440 00:05:19.450 as the leading supplier of plate heat
00:05:23.580 00:05:23.590 exchangers in the world Alfa Laval is
00:05:27.540 00:05:27.550 your natural first choice
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12

Phone: +7 343 216 77 75

E-mail: info@lotus1.ru

Sales phone

Russia: +7 343 216 77 75

WhatsApp: +79122710308