/ News & Press / Video / Furnace Blower Not Running — Furnace Troubleshooting
Furnace Blower Not Running — Furnace Troubleshooting
WEBVTT Kind: captions Language: en
00:00:01.340 repair clinic makes fixing things easy 00:00:04.38900:00:04.399 with millions of replacement parts 00:00:06.76900:00:06.779 available on our website and the help 00:00:09.44000:00:09.450 you need to do the repair yourself if 00:00:12.77000:00:12.780 your furnace blower is not running here 00:00:15.86000:00:15.870 are the top four most probable causes 00:00:19.33000:00:19.340 the blower motor blows air through the 00:00:22.09900:00:22.109 return vent pass the heat exchanger and 00:00:24.52900:00:24.539 into the homes venting if the blower 00:00:27.71000:00:27.720 motor does not run first confirm that 00:00:30.14000:00:30.150 the motor is receiving power if it is 00:00:32.90000:00:32.910 then it's likely the motor has burned 00:00:34.94000:00:34.950 out if the motor hums and the blower 00:00:38.36000:00:38.370 wheel is unobstructed but will not turn 00:00:40.64000:00:40.650 freely it's likely the motor bearings 00:00:43.34000:00:43.350 are locked up and the motor will need to 00:00:45.29000:00:45.300 be replaced the capacitor stores an 00:00:49.85000:00:49.860 electrical charge and then releases it 00:00:52.19000:00:52.200 in order to start the blower motor if 00:00:54.58000:00:54.590 the blower motor does not start or start 00:00:57.86000:00:57.870 slowly the capacitor may be faulty when 00:01:01.82000:01:01.830 a capacitor fails it will often bulge or 00:01:04.34000:01:04.350 leak if there are no visible signs of 00:01:07.94000:01:07.950 damage you can test the capacitor using 00:01:10.37000:01:10.380 an analogue style ohmmeter or a 00:01:12.20000:01:12.210 capacitor tester to determine if the 00:01:14.69000:01:14.700 component is working properly before 00:01:18.71000:01:18.720 handling the capacitor you should 00:01:20.96000:01:20.970 release the potentially stored 00:01:22.43000:01:22.440 electrical charge to avoid injury you 00:01:25.37000:01:25.380 can do this by placing a screw driver 00:01:27.20000:01:27.210 with an insulated handle across each set 00:01:29.78000:01:29.790 of terminals be very careful not to 00:01:32.48000:01:32.490 touch the screwdriver blade when doing 00:01:34.64000:01:34.650 this the Control Board regulates the 00:01:38.81000:01:38.820 power supply to all of the furnace 00:01:40.55000:01:40.560 components a defective control board may 00:01:43.96900:01:43.979 not send voltage to the blower motor an 00:01:47.98000:01:47.990 incoming power problem could also result 00:01:50.69000:01:50.700 in the blower not running make sure the 00:01:53.81000:01:53.820 furnace power switch is in the on 00:01:55.39900:01:55.409 position and check to see if a circuit 00:01:58.25000:01:58.260 breaker has tripped or a fuse has blown 00:02:00.61000:02:00.620 all of the parts shown in this video are 00:02:04.10000:02:04.110 available on our website for additional 00:02:07.16000:02:07.170 troubleshooting information enter the 00:02:09.91900:02:09.929 full model number of your furnace in our 00:02:12.19900:02:12.209 repair help search bar at repair clinic 00:02:17.42000:02:17.430 we make fixing things easy thank you for 00:02:20.80900:02:20.819 supporting the production of these 00:02:22.22000:02:22.230 videos by purchasing your parts from our 00:02:24.55900:02:24.569 website
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12