/ News & Press / Video / Furnace Blower Not Working - How to Check It
Furnace Blower Not Working - How to Check It
WEBVTT Kind: captions Language: en
00:00:08.240 hey guys J here with word of advice TV 00:00:11.03000:00:11.040 in my comment sections on a lot of my 00:00:13.00900:00:13.019 a/c fixing videos people are asking me 00:00:15.47000:00:15.480 how do I check if my blower motor in my 00:00:18.01900:00:18.029 furnace is bad or not so for example the 00:00:20.17900:00:20.189 unit outside will turn on the compressor 00:00:22.16000:00:22.170 and a fan everything seems to be working 00:00:23.54000:00:23.550 out there but you come downstairs and 00:00:25.88000:00:25.890 the blower motor is not turning out so 00:00:28.04000:00:28.050 is it simply not getting power or is the 00:00:29.99000:00:30.000 blower motor just burnt out chances are 00:00:32.15000:00:32.160 if you've been trying to run it for 5-10 00:00:34.16000:00:34.170 minutes if you take your furnace doors 00:00:36.53000:00:36.540 off and if you carefully reach in where 00:00:39.08000:00:39.090 the blower motor is in fact you might 00:00:41.06000:00:41.070 want to turn the power switch off and if 00:00:43.79000:00:43.800 you have a voltage spend confirm to make 00:00:46.25000:00:46.260 sure you don't have any power anywhere 00:00:47.77900:00:47.789 so you don't accidentally get shocked as 00:00:51.02000:00:51.030 you can see I have power here see that 00:00:52.79000:00:52.800 with my voltage pen so you want to turn 00:00:55.45900:00:55.469 that off and I can check again 00:00:58.36900:00:58.379 I have no power anywhere now so now that 00:01:03.47000:01:03.480 I've verified there's no power 00:01:04.85000:01:04.860 just take your furnace doors off if you 00:01:06.64900:01:06.659 reach in on the motor side which is 00:01:08.33000:01:08.340 typically on the right side and just 00:01:11.46900:01:11.479 grab the motor a lot of times if it's 00:01:15.20000:01:15.210 been trying to start the motor will be 00:01:16.73000:01:16.740 super hot also if you go on the left 00:01:20.63000:01:20.640 side and feel the squirrel-cage a lot of 00:01:24.71000:01:24.720 times it'll not spin very freely it'll 00:01:26.81000:01:26.820 feel kind of sluggish and seized up just 00:01:29.66000:01:29.670 trying to spin that by hand be careful 00:01:31.52000:01:31.530 though because the fins can be sharp 00:01:33.42900:01:33.439 those are pretty much obvious giveaways 00:01:36.62000:01:36.630 that your motor is bad if that motor is 00:01:38.78000:01:38.790 super hot 00:01:39.53000:01:39.540 another possibility though is that your 00:01:41.69000:01:41.700 capacitor is actually weak or completely 00:01:44.63000:01:44.640 dead and your capacitor is typically 00:01:47.17900:01:47.189 going to be on the motor housing 00:01:48.28900:01:48.299 somewhere mine for example is right here 00:01:50.71900:01:50.729 it's going to be that silver cylinder so 00:01:53.38900:01:53.399 what you want to do is take off the 00:01:54.71000:01:54.720 capacitor just got like the wires from 00:01:56.27000:01:56.280 it and using your meter on the micro 00:01:58.81900:01:58.829 farad selection right here 00:02:00.99900:02:01.009 you want to check the capacitor and see 00:02:03.80000:02:03.810 if the rating is matching up the label 00:02:06.31900:02:06.329 on it now I won't go into how to check 00:02:08.41900:02:08.429 the capacitor in this video but I do 00:02:10.33900:02:10.349 have a whole nother video that talks all 00:02:12.14000:02:12.150 about the capacitor 00:02:13.23000:02:13.240 to check it and replace it in an AC 00:02:14.88000:02:14.890 condenser unit but it would be the same 00:02:17.07000:02:17.080 thing here too so I won't get into that 00:02:19.05000:02:19.060 now but if you want just check out the 00:02:20.70000:02:20.710 other video to know more about the 00:02:22.02000:02:22.030 capacitor part so if your capacitor is 00:02:24.39000:02:24.400 good and your motor is hot then almost 00:02:27.72000:02:27.730 guaranteed that you need a new motor but 00:02:29.97000:02:29.980 we don't want to guess so to know for 00:02:32.07000:02:32.080 sure what you want to do is turn that 00:02:34.62000:02:34.630 power back on we're gonna do this test 00:02:36.27000:02:36.280 with the power on turn the power back on 00:02:39.57000:02:39.580 take out your furnace doors make sure 00:02:41.64000:02:41.650 your door switch is taped otherwise you 00:02:44.07000:02:44.080 won't have power anywhere when you're 00:02:45.87000:02:45.880 taping it or putting a screw in it or 00:02:48.00000:02:48.010 jamming it or whatever make sure you 00:02:50.07000:02:50.080 don't touch any connectors in the back 00:02:51.45000:02:51.460 because it is 120 volts and you will get 00:02:54.00000:02:54.010 it shocked and possibly something worse 00:02:56.10000:02:56.110 and then you want to locate your fan 00:02:58.11000:02:58.120 wires the wires coming from your fan 00:03:00.63000:03:00.640 motor in my case it's the blue black red 00:03:03.60000:03:03.610 and white and see where they go into on 00:03:05.88000:03:05.890 the control board in my case black goes 00:03:08.79000:03:08.800 to cooling right there I have nothing on 00:03:11.43000:03:11.440 Park 00:03:12.06000:03:12.070 no spare wires or no spare fan speeds 00:03:14.67000:03:14.680 red is heat low stage and blue is heat 00:03:18.42000:03:18.430 high stage so depending on if you're in 00:03:21.66000:03:21.670 the furnace season or AC season right 00:03:24.57000:03:24.580 now we're in an AC season you will pull 00:03:26.28000:03:26.290 that wire off so in my case it'll be the 00:03:28.98000:03:28.990 black wire I'll pull that wire off like 00:03:33.15000:03:33.160 that and also I will find where my 00:03:36.42000:03:36.430 common is coming from the motor and 00:03:39.33000:03:39.340 usually it'll say search or circulator 00:03:41.73000:03:41.740 and I will pull that off as well 00:03:45.92000:03:45.930 after you have those two wires pulled 00:03:48.54000:03:48.550 off with your thermostat calling for 00:03:52.02000:03:52.030 cooling your outside unit running the 00:03:54.69000:03:54.700 fan should be turning on so what you 00:03:56.58000:03:56.590 want to do is just verify that it's 00:03:58.17000:03:58.180 getting power so you'll put one lead on 00:04:00.42000:04:00.430 the cool Spade where he pulled the 00:04:02.49000:04:02.500 cooling speed wire off of one of your 00:04:05.64000:04:05.650 leads will go on that and the other one 00:04:07.41000:04:07.420 will go on the common or the circulator 00:04:09.21000:04:09.220 common the other wire that you pulled 00:04:10.89000:04:10.900 off you want to have that set to voltage 00:04:13.50000:04:13.510 and when you check that if your motor is 00:04:18.00000:04:18.010 getting power it'll have a hundred 00:04:19.80000:04:19.810 twenty volts if you're not getting 00:04:21.93000:04:21.940 voltage that means actually your control 00:04:24.90000:04:24.910 board is simply not sending power 00:04:26.53000:04:26.540 to the blower motor and it's probably 00:04:28.54000:04:28.550 the board that's bad and not the motor 00:04:30.73000:04:30.740 itself but if the board is sending a 00:04:33.70000:04:33.710 hundred twenty volts to the blower motor 00:04:36.22000:04:36.230 that means the blower motor is bad if 00:04:39.13000:04:39.140 it's not turning on and then don't 00:04:40.99000:04:41.000 forget to plug the wires back in now if 00:04:43.54000:04:43.550 you don't have a meter and you can't 00:04:45.07000:04:45.080 check if your blower motor is getting 00:04:46.72000:04:46.730 voltage or not one way you could try 00:04:48.70000:04:48.710 testing it is to hotwire it directly so 00:04:52.30000:04:52.310 for example you turn your power switch 00:04:54.85000:04:54.860 off you don't want to have any power 00:04:57.24000:04:57.250 confirm with the voltage pen or a meter 00:04:59.47000:04:59.480 that you don't have any voltage anywhere 00:05:01.33000:05:01.340 and I don't and then what you want to do 00:05:05.26000:05:05.270 is find your line terminal where the 00:05:08.35000:05:08.360 power comes into the control board 00:05:10.06000:05:10.070 you want to pull that wire off so in my 00:05:14.17000:05:14.180 case it'll be this one right here it'll 00:05:18.25000:05:18.260 usually be coming from the door switch 00:05:20.79000:05:20.800 pull that wire off and then if you're 00:05:24.31000:05:24.320 the furnace season you want to pull off 00:05:26.08000:05:26.090 your heat wire if you're into AC season 00:05:28.15000:05:28.160 which we are right now you wanna pull 00:05:29.92000:05:29.930 off your cooling wire which is this one 00:05:31.66000:05:31.670 basically all you're going to do is 00:05:33.31000:05:33.320 bypass the control board and send power 00:05:35.77000:05:35.780 to the blower motor directly so this is 00:05:39.13000:05:39.140 line voltage coming in from the junction 00:05:41.14000:05:41.150 box or the power switch all you got to 00:05:43.72000:05:43.730 do is wire nut if you want you can snip 00:05:46.99000:05:47.000 these two wires off and then why you're 00:05:50.62000:05:50.630 not them together 00:05:51.69000:05:51.700 that'll be sending power directly to the 00:05:55.21000:05:55.220 blower motor so you would snip them both 00:05:57.94000:05:57.950 put the wire nut on will strip them and 00:06:00.70000:06:00.710 then put the way that on to tie it 00:06:02.92000:06:02.930 straight into power if your blower motor 00:06:05.41000:06:05.420 comes on that means you know your 00:06:07.90000:06:07.910 control board is bad it's just not 00:06:09.49000:06:09.500 sending power to the motor if the blower 00:06:12.85000:06:12.860 motor does not come on while it's 00:06:15.10000:06:15.110 bypassed like that that means your 00:06:16.96000:06:16.970 blower motor is bad and it needs to be 00:06:18.73000:06:18.740 replaced and the way I usually do it in 00:06:21.04000:06:21.050 the field when I do this test or 00:06:24.13000:06:24.140 sometimes if I need to order a customer 00:06:25.96000:06:25.970 a control board and just to get them by 00:06:28.26000:06:28.270 until I can get the new board in I 00:06:31.26000:06:31.270 usually use a spade like that a splitter 00:06:34.17000:06:34.180 so I'll put the door switch on one end 00:06:37.44000:06:37.450 I'll put the cooling speed from the fan 00:06:40.60000:06:40.610 on the other end like that and then I 00:06:44.56000:06:44.570 would just plug this right back in to 00:06:47.26000:06:47.270 the line voltage terminal right here and 00:06:51.27000:06:51.280 that will be sending power to my motor 00:06:53.83000:06:53.840 directly from the power switch instead 00:06:56.29000:06:56.300 of through the control board 00:06:57.49000:06:57.500 well guys and that is how you check if 00:06:59.20000:06:59.210 your blower motor is bad or if it's just 00:07:01.30000:07:01.310 the control board not sending power to 00:07:02.95000:07:02.960 it hopefully you found this video useful 00:07:04.36000:07:04.370 thank you so much for watching don't 00:07:06.31000:07:06.320 forget to mash that like button on the 00:07:07.60000:07:07.610 way out and I'll see you next time 00:07:24.45000:07:24.460 you
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12