/ News & Press / Video / Furnace Motor & Capacitor _ Repair and Replace
Furnace Motor & Capacitor _ Repair and Replace
WEBVTT Kind: captions Language: en
00:00:02.060 [Music] 00:00:11.29000:00:11.300 hi I'm Vance and welcome back to repair 00:00:15.25900:00:15.269 and replace in this episode I'll show 00:00:18.20000:00:18.210 you how to replace the blower motor in a 00:00:20.42000:00:20.430 gas furnace when the burner is lit the 00:00:27.89000:00:27.900 blower fan is too late from running to 00:00:29.90000:00:29.910 allow the heat exchanger to warm up this 00:00:32.74900:00:32.759 prevents the furnace from circulating 00:00:34.63900:00:34.649 cold air the blower fan then pushes the 00:00:38.18000:00:38.190 air over the heat exchanger and 00:00:39.86000:00:39.870 circulates it around your home if the 00:00:43.01000:00:43.020 blower motor is receiving power and 00:00:44.90000:00:44.910 still won't turn then the motor might be 00:00:47.45000:00:47.460 seized or burnt out some motors use a 00:00:51.17000:00:51.180 capacitor to energize the axillary 00:00:53.29900:00:53.309 winding this creates a magnetic phase 00:00:56.95900:00:56.969 shift providing the torque needed to 00:00:58.91000:00:58.920 turn the rotor 00:01:03.93000:01:03.940 weaken or fail over time preventing the 00:01:06.35900:01:06.369 motor for running or starting properly 00:01:08.28000:01:08.290 so it's recommended to also replace the 00:01:10.98000:01:10.990 capacitor when replacing a motor to 00:01:15.24000:01:15.250 begin you might need a socket wrench or 00:01:17.55000:01:17.560 nut driver an adjustable wrench and 00:01:20.30000:01:20.310 gloves 00:01:26.85900:01:26.869 when working on your furnace always shut 00:01:29.63000:01:29.640 off the power at closed gas valve remove 00:01:34.49000:01:34.500 the top cover panel many furnaces use a 00:01:37.55000:01:37.560 push lock or twist lock but some 00:01:39.88900:01:39.899 furnaces will require a screwdriver or a 00:01:42.71000:01:42.720 socket wrench 00:01:45.03900:01:45.049 now remove the blower cover panel when 00:01:54.26000:01:54.270 accessing the blower assembly it's best 00:01:56.51000:01:56.520 to wear cut resistant gloves sheet metal 00:01:59.24000:01:59.250 can have sharp edges so be careful next 00:02:03.19900:02:03.209 unscrew the mounting screws you might 00:02:08.02900:02:08.039 have to 00:02:08.70000:02:08.710 move the control board if it's mounted 00:02:10.59000:02:10.600 in front of the blower first take a 00:02:13.53000:02:13.540 picture so you'll know how to reconnect 00:02:15.78000:02:15.790 the wires afterwards now disconnect the 00:02:19.71000:02:19.720 motor wires unscrew and set the control 00:02:25.08000:02:25.090 board off to the side now slide the 00:02:30.54000:02:30.550 blower assembly out first loosen the 00:02:38.25000:02:38.260 screw that secures the blower wheel to 00:02:40.62000:02:40.630 the motor shaft now flip the assembly 00:02:44.16000:02:44.170 over 00:02:51.14000:02:51.150 always assume capacitors are charged as 00:02:54.08900:02:54.099 there is a risk of a serious electrical 00:02:56.58000:02:56.590 shock 00:02:57.38000:02:57.390 you can place a resistor or screwdriver 00:03:00.78000:03:00.790 with an insulated handle across each 00:03:03.36000:03:03.370 terminal this will short out and 00:03:05.67000:03:05.680 discharge the capacitor 00:03:08.65000:03:08.660 now disconnect the wires and remove the 00:03:11.74000:03:11.750 capacitor the capacitance expressed in 00:03:16.57000:03:16.580 micro farad's is a rating of how much 00:03:18.94000:03:18.950 energy can be stored in capacitor this 00:03:21.73000:03:21.740 should be matched exactly 00:03:25.04000:03:25.050 the voltage rating refers to the maximum 00:03:27.50000:03:27.510 voltage that it can handle you can use a 00:03:29.99000:03:30.000 capacitor with an equal or higher 00:03:31.64000:03:31.650 voltage rating but never with a lower 00:03:34.28000:03:34.290 rating as this can result in capacitor 00:03:36.71000:03:36.720 failure 00:03:41.41000:03:41.420 next use a socket wrench to remove the 00:03:44.92900:03:44.939 mounting screws holding the motor to the 00:03:47.30000:03:47.310 housing now remove the motor 00:03:55.31000:03:55.320 take note and mark the position of the 00:03:58.68000:03:58.690 motor in the mounting bracket unscrew 00:04:03.90000:04:03.910 the bracket screws and remove the motor 00:04:13.37000:04:13.380 the motor nameplate is the key for 00:04:16.08000:04:16.090 finding a replacement as it lists the 00:04:18.09000:04:18.100 model number and electrical specs of the 00:04:20.34000:04:20.350 motor in some cases the model number can 00:04:23.25000:04:23.260 be used to find an OEM motor or a direct 00:04:26.16000:04:26.170 cross reference if needed you can still 00:04:28.92000:04:28.930 use the motor specifications to find a 00:04:31.32000:04:31.330 proper replacement first match the 00:04:34.92000:04:34.930 physical specs this includes the motor 00:04:37.47000:04:37.480 diameter shaft size and mounting type 00:04:40.46000:04:40.470 then match the electrical specs which 00:04:43.95000:04:43.960 includes horsepower voltage amps rpm 00:04:48.40900:04:48.419 rotation motor type and capacitor size 00:04:59.60000:04:59.610 slide the new motor into the bracket and 00:05:02.62900:05:02.639 align the position with the mark 00:05:09.80000:05:09.810 now tighten the bracket screws 00:05:16.66000:05:16.670 slide the motor shaft into the blower 00:05:19.73000:05:19.740 wheel now align the holes in the 00:05:23.60000:05:23.610 mounting bracket and tighten the screws 00:05:29.38000:05:29.390 Center the blower wheel and align the 00:05:32.03000:05:32.040 flat side of the motor shaft and tighten 00:05:35.54000:05:35.550 the setscrew now reconnect the ground 00:05:40.22000:05:40.230 wire and replace the capacitor align the 00:05:51.23000:05:51.240 rails and slide the blower assembly into 00:05:53.75000:05:53.760 place next secure the control board and 00:06:00.94000:06:00.950 reconnect the wires now tighten the 00:06:07.73000:06:07.740 mounting screws 00:06:15.17000:06:15.180 many furnaces have a switch that cuts 00:06:17.85000:06:17.860 power to the furnace if the blower cover 00:06:20.10000:06:20.110 is open so make sure that the panel is 00:06:22.65000:06:22.660 properly aligned and secure now replace 00:06:27.09000:06:27.100 the upper cover 00:06:31.26000:06:31.270 next open the gas valve now turn on the 00:06:36.25000:06:36.260 power to your furnace the furnace should 00:06:40.15000:06:40.160 be running normally if you like this and 00:06:45.58000:06:45.590 want to see more tutorials and 00:06:47.26000:06:47.270 informational videos then subscribe to 00:06:49.75000:06:49.760 our Channel and if you need help you can 00:06:52.42000:06:52.430 call or visit a name relocation to talk 00:06:55.24000:06:55.250 with our knowledgeable staff thanks for 00:06:58.06000:06:58.070 watching 00:07:05.82000:07:05.830 you
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12