00:00:07.670
ha Gastner has designed a log boiler
00:00:10.610 00:00:10.620 series providing satisfaction on
00:00:13.039 00:00:13.049 economic efficiency and high comfort
00:00:15.680 00:00:15.690 levels equally suitable for newly builds
00:00:18.980 00:00:18.990 with low or retrofits with higher energy
00:00:21.679 00:00:21.689 heating requirements compared to the
00:00:25.160 00:00:25.170 ever increasing oil and gas prices log
00:00:28.099 00:00:28.109 prices remain at the same low level with
00:00:32.150 00:00:32.160 a biomass boiler from HA Gastner you
00:00:34.639 00:00:34.649 lower your heating bill and at the same
00:00:36.709 00:00:36.719 time protect an environment for our
00:00:38.869 00:00:38.879 children to enjoy logs are sourced from
00:00:51.920 00:00:51.930 local forests up-to-date machinery
00:00:56.029 00:00:56.039 guarantees easy and economical
00:00:58.010 00:00:58.020 production
00:01:14.560 00:01:14.570 the new wood log gasification boiler
00:01:17.530 00:01:17.540 from Haga sauna the big feeling opening
00:01:23.080 00:01:23.090 allows convenient filling as half-meter
00:01:29.410 00:01:29.420 logs aren't always have exactly the same
00:01:31.180 00:01:31.190 length
00:01:31.870 00:01:31.880 Haga sauna has extended the filling area
00:01:34.570 00:01:34.580 to 580 millimeters over length on a
00:01:37.930 00:01:37.940 longer an issue the boiler can be
00:01:45.340 00:01:45.350 manually ignited conveniently through
00:01:47.290 00:01:47.300 the ignition door
00:01:52.350 00:01:52.360 with the patented ha Gastner automatic
00:01:55.270 00:01:55.280 ignition it is even more comfortable
00:01:57.810 00:01:57.820 during the summer or in the transition
00:02:00.520 00:02:00.530 period to winter the boiler can be
00:02:02.560 00:02:02.570 filled with logs and ignition materials
00:02:04.720 00:02:04.730 at any time and ignites automatically if
00:02:07.420 00:02:07.430 heat is required for winter operation
00:02:11.200 00:02:11.210 the boiler is fitted with a slumber mode
00:02:13.600 00:02:13.610 operation this allows for easy refilling
00:02:16.720 00:02:16.730 even hours later without new ignition
00:02:27.960 00:02:27.970 with an easy-to-use mirror checking the
00:02:30.330 00:02:30.340 flame is significantly simplified after
00:02:34.710 00:02:34.720 ignition the boiler output is controlled
00:02:37.260 00:02:37.270 by primary air supply optimized
00:02:40.860 00:02:40.870 combustion is guaranteed by the
00:02:42.540 00:02:42.550 secondary air pre-warmed by the
00:02:44.760 00:02:44.770 refractory refractory has proved to be
00:02:51.840 00:02:51.850 the best material with regard to heat
00:02:53.610 00:02:53.620 storage capacity nan Javits II and
00:02:55.860 00:02:55.870 functionality the high combustion
00:02:58.710 00:02:58.720 chamber temperatures of above 1,000
00:03:01.140 00:03:01.150 degrees centigrade during full and
00:03:02.790 00:03:02.800 partial load operation and to the high
00:03:05.310 00:03:05.320 efficiency and extremely low emissions
00:03:07.760 00:03:07.770 the combination of refractory line
00:03:10.410 00:03:10.420 combustion chamber and lambo control in
00:03:12.930 00:03:12.940 combination with a specialized load
00:03:14.880 00:03:14.890 control allows for optimized operation
00:03:17.910 00:03:17.920 with lowest emissions and highest
00:03:19.770 00:03:19.780 efficiency this saves costs and energy
00:03:27.100 00:03:27.110 the hot combustion gas flows through the
00:03:30.130 00:03:30.140 heat exchanger and is guided towards the
00:03:32.770 00:03:32.780 heat exchanger walls by turbulator x'
00:03:34.750 00:03:34.760 guaranteeing maximized energy recovery a
00:03:37.710 00:03:37.720 speed controlled exhaust gas fan allows
00:03:41.410 00:03:41.420 full and partial load operation
00:03:43.510 00:03:43.520 independent of the flue
00:03:46.690 00:03:46.700 in combination with the optimized low
00:03:49.370 00:03:49.380 temperature combustion gas offtake
00:03:51.500 00:03:51.510 it prevents smoke from coming out of the
00:03:53.780 00:03:53.790 boiler during refilling during each
00:03:57.350 00:03:57.360 opening of the filling door the tube you
00:03:59.540 00:03:59.550 laters are agitated this automatic
00:04:02.270 00:04:02.280 cleaning of the heat exchanger surface
00:04:04.010 00:04:04.020 causes a constant ideal heat transfer
00:04:06.770 00:04:06.780 and guarantees high efficiency this is
00:04:12.320 00:04:12.330 your unique Hargis neck heating comfort
00:04:14.720 00:04:14.730 a special highlight is the HAR Gastner
00:04:19.580 00:04:19.590 touch display this state-of-the-art
00:04:22.159 00:04:22.169 control operates the whole heating
00:04:24.380 00:04:24.390 system from combustion to heat
00:04:26.180 00:04:26.190 distribution and hot water supply your
00:04:28.820 00:04:28.830 heating system can very easily be
00:04:31.070 00:04:31.080 controlled by a touch of the finger
00:04:32.830 00:04:32.840 there are no buttons the symbols and
00:04:35.659 00:04:35.669 images are self-explanatory visually you
00:04:38.750 00:04:38.760 can immediately identify the current
00:04:40.310 00:04:40.320 status of the boiler accumulator and hot
00:04:42.650 00:04:42.660 water tank as well as the whole heating
00:04:45.050 00:04:45.060 circuit and adjustments are child's play
00:04:47.990 00:04:48.000 just click on the relevant picture and
00:04:50.570 00:04:50.580 adjust the settings an analog remote
00:04:56.510 00:04:56.520 control FR 25 a digital FR 40 or a
00:05:00.380 00:05:00.390 digital FR 35 allows a comfortable
00:05:04.250 00:05:04.260 operation from within your living area
00:05:06.320 00:05:06.330 fr 35 is also available with radio if
00:05:09.650 00:05:09.660 required with the SMS remote control or
00:05:12.620 00:05:12.630 the all-new ha Gastner AP p you can
00:05:15.530 00:05:15.540 easily request boiler information switch
00:05:18.020 00:05:18.030 heating circuits on or off and change
00:05:20.390 00:05:20.400 temperatures from all over the world ha
00:05:23.300 00:05:23.310 Gastner has perfected the accumulator
00:05:25.340 00:05:25.350 tank control during start-up the heat is
00:05:28.730 00:05:28.740 reroute admire quick load valve to send
00:05:31.310 00:05:31.320 heat as quickly as possible to the
00:05:32.810 00:05:32.820 living area as soon as the boiler starts
00:05:35.510 00:05:35.520 to store the excess heat in the
00:05:37.219 00:05:37.229 accumulator tank the boiler is set to
00:05:39.800 00:05:39.810 partial load this extends the combustion
00:05:42.350 00:05:42.360 period and increases heating comfort the
00:05:45.230 00:05:45.240 HAR Gastner 1/2 meter log boilers are
00:05:47.690 00:05:47.700 available from 20 to 60 kilowatts as 1
00:05:51.590 00:05:51.600 meter log boilers they are available
00:05:53.659 00:05:53.669 with 35 or 49 kilowatts
00:05:56.570 00:05:56.580 and if required can be delivered with a
00:05:58.129 00:05:58.139 side feed opening optimally designed for
00:06:01.309 00:06:01.319 all ha Gastner products layered
00:06:03.439 00:06:03.449 accumulators and hygienic layered
00:06:05.570 00:06:05.580 accumulators complete the product range
00:06:07.670 00:06:07.680 if you decide on a hog asana log boiler
00:06:10.879 00:06:10.889 you of course get the renowned ha
00:06:13.189 00:06:13.199 Gastner top class heating comfort highly
00:06:16.249 00:06:16.259 convenient and of course state of the
00:06:19.490 00:06:19.500 art technology a guarantee for lowest
00:06:21.740 00:06:21.750 emissions highly ecological more than 30
00:06:26.659 00:06:26.669 years experience as a specialist in the
00:06:28.760 00:06:28.770 biomass industry are combined in your
00:06:31.399 00:06:31.409 product ha Gastner stands for the
00:06:33.800 00:06:33.810 highest efficiency and lowest fuel
00:06:35.899 00:06:35.909 consumption highly economical catch up
00:06:40.249 00:06:40.259 on the wide range of funding in
00:06:41.809 00:06:41.819 different countries and obtain
00:06:43.610 00:06:43.620 government funding for
00:06:44.779 00:06:44.789 environmentally-friendly heating systems
00:06:47.320 00:06:47.330 ha Gastner offers a comprehensive boiler
00:06:50.240 00:06:50.250 range from nine to 200 kilowatts with
00:06:53.809 00:06:53.819 multiple boiler systems up to 800
00:06:56.059 00:06:56.069 kilowatts did we get your attention
00:06:59.350 00:06:59.360 request a product specific brochure or
00:07:02.510 00:07:02.520 obtain information locally from one of
00:07:05.269 00:07:05.279 our highly trained partners par Gastner
00:07:10.399 00:07:10.409 heating technology with a future
00:07:13.059 00:07:13.069 additional information available at