/ News & Press / Video / How Does a Dehumidifier Work — Appliance Repair Tips
How Does a Dehumidifier Work — Appliance Repair Tips
WEBVTT Kind: captions Language: en
00:00:06.460 while dehumidifiers can differ from 00:00:09.37000:00:09.380 model to model they all operate on 00:00:11.89000:00:11.900 similar principles in this video we will 00:00:15.67000:00:15.680 identify the main factors of 00:00:17.44000:00:17.450 dehumidifier operation as well as 00:00:19.90000:00:19.910 potential problems you may encounter 00:00:23.25000:00:23.260 dehumidifiers reduce the humidity level 00:00:25.93000:00:25.940 in your home by drawing the room air 00:00:28.02900:00:28.039 through the appliance and removing the 00:00:30.04000:00:30.050 moisture the level of humidity reduction 00:00:33.16000:00:33.170 is regulated by the humidistat or by a 00:00:35.97900:00:35.989 control board with a sensor when the 00:00:39.75900:00:39.769 humidistat or sensor detects a need to 00:00:42.06900:00:42.079 reduce the moisture in the air 120 volts 00:00:45.27900:00:45.289 of alternating current is sent to the 00:00:47.28900:00:47.299 compressor and the fan motor the 00:00:50.68000:00:50.690 compressor is part of a sealed 00:00:52.18000:00:52.190 refrigerant system that compresses the 00:00:54.39900:00:54.409 refrigerant in gas form and pumps it 00:00:56.68000:00:56.690 through a set of condenser coils where 00:00:58.75000:00:58.760 the gas becomes a hot liquid the coils 00:01:01.95900:01:01.969 dissipate the heat as the liquid travels 00:01:04.24000:01:04.250 through them once the refrigerant has 00:01:07.69000:01:07.700 passed through the condenser coils and 00:01:09.58000:01:09.590 the capillary tube it travels to the 00:01:12.28000:01:12.290 evaporator coils as the refrigerant 00:01:15.64000:01:15.650 liquid enters these coils it expands 00:01:18.01000:01:18.020 into a gas which makes the coils cold 00:01:20.70000:01:20.710 the gas flows through the coils to a 00:01:23.44000:01:23.450 suction line attached to the compressor 00:01:25.45000:01:25.460 the compressor will then pump the gas 00:01:27.91000:01:27.920 back into the condenser coils where it 00:01:30.28000:01:30.290 once again becomes a liquid and the 00:01:32.38000:01:32.390 cycle continues at the same time the fan 00:01:37.03000:01:37.040 motor rotates a blade to draw the rooms 00:01:39.49000:01:39.500 humid air into the appliance where it 00:01:41.74000:01:41.750 condenses on the cold evaporator coils 00:01:44.52000:01:44.530 the condensation accumulates on the 00:01:47.32000:01:47.330 evaporator and drips into a bucket or is 00:01:50.11000:01:50.120 diverted through a hose to a floor drain 00:01:53.07000:01:53.080 the cooler air from the evaporator is 00:01:55.96000:01:55.970 heated as it passes through the 00:01:57.58000:01:57.590 condenser coils and is returned to the 00:01:59.83000:01:59.840 room this process continues until enough 00:02:03.76000:02:03.770 moisture has been removed from the air 00:02:05.41000:02:05.420 to satisfy the setting on the humidistat 00:02:07.57000:02:07.580 or the control board most dehumidifier 00:02:12.61000:02:12.620 models are equipped with a 00:02:14.17000:02:14.180 it's switch that will prevent the 00:02:15.94000:02:15.950 appliance from running if the bucket is 00:02:17.64900:02:17.659 full 00:02:18.44900:02:18.459 if you suspect the dehumidifier should 00:02:21.06900:02:21.079 be running when it's not the buckets 00:02:23.41000:02:23.420 which may be defective you can use an 00:02:27.36900:02:27.379 ohm meter to test the switch for 00:02:29.02000:02:29.030 continuity to help determine if the 00:02:31.20900:02:31.219 switch is functioning or not both the 00:02:35.70900:02:35.719 condenser and evaporator coils need 00:02:38.11000:02:38.120 proper air flow for the dehumidifier to 00:02:40.36000:02:40.370 work efficiently over time these coils 00:02:43.69000:02:43.700 can collect dust dirt and debris so it's 00:02:46.69000:02:46.700 a good idea to clean the coils regularly 00:02:48.97000:02:48.980 just be careful not to bend the fins 00:02:55.22000:02:55.230 if you hear the dehumidifier running but 00:02:57.92000:02:57.930 no air is being exhausted then it's 00:03:00.19900:03:00.209 likely that the fan motor has failed and 00:03:02.27000:03:02.280 will need to be replaced if your model 00:03:05.66000:03:05.670 is equipped with an air filter the 00:03:07.52000:03:07.530 filter will need to be cleaned from time 00:03:09.35000:03:09.360 to time to prevent frost from building 00:03:11.66000:03:11.670 up on the evaporator coils most standard 00:03:20.66000:03:20.670 dehumidifier models require the room 00:03:22.75900:03:22.769 temperature to remain above 65 degrees 00:03:25.07000:03:25.080 Fahrenheit for the appliance to work 00:03:26.99000:03:27.000 properly as lower temperatures can cause 00:03:29.42000:03:29.430 the evaporator coils to frost over if 00:03:32.02000:03:32.030 the temperature in your home regularly 00:03:34.37000:03:34.380 drops below 65 degrees you will need to 00:03:37.52000:03:37.530 obtain a model that is specifically 00:03:39.17000:03:39.180 designated for lower temperature 00:03:40.91000:03:40.920 operation repair clinic has a solution 00:03:45.02000:03:45.030 for many of the problems you may be 00:03:46.91000:03:46.920 experiencing with your dehumidifier 00:03:49.44900:03:49.459 enter the appliances full model number 00:03:52.19000:03:52.200 in our website search engine for a 00:03:54.50000:03:54.510 complete list of compatible parts our 00:03:57.16000:03:57.170 site also has an extensive selection of 00:04:00.19900:04:00.209 instructional videos to assist you 00:04:02.15000:04:02.160 covering topics like part testing 00:04:04.96000:04:04.970 disassembly and part replacement at 00:04:09.09900:04:09.109 repair clinic we make fixing things easy 00:04:18.72000:04:18.730 you
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12