Hvac condenser coil coating

WEBVTT
Kind: captions
Language: en

00:00:15.830
okay
00:00:17.660 00:00:17.670 ac pal we're in comfort well he have
00:00:21.320 00:00:21.330 this the Commons but today we're on unit
00:00:24.109 00:00:24.119 number two
00:00:25.970 00:00:25.980 previously when the coil was installed
00:00:30.940 00:00:30.950 we'll be spray-painting with an epoxy
00:00:33.100 00:00:33.110 coating protect the coil today I pretty
00:00:38.080 00:00:38.090 much have everything set off
00:00:41.349 00:00:41.359 take off that we don't get anything on
00:00:44.529 00:00:44.539 the accident panels
00:00:46.049 00:00:46.059 others might think differently I would
00:00:49.299 00:00:49.309 prefer to do it when the fans are on
00:00:50.919 00:00:50.929 especially when we're on the roof due to
00:00:53.590 00:00:53.600 the fact that there's there's heavy
00:00:55.810 00:00:55.820 winds so I would prefer that when I
00:00:57.849 00:00:57.859 spray the actual epoxy coating it goes
00:01:02.319 00:01:02.329 through and pretty much gets expelled
00:01:06.490 00:01:06.500 through the top of the actual gets
00:01:08.350 00:01:08.360 exhausted out through the top of the
00:01:10.270 00:01:10.280 condenser even though some particles
00:01:12.429 00:01:12.439 might get onto the blade etc but that's
00:01:15.130 00:01:15.140 just my new Barry my new then like an
00:01:18.219 00:01:18.229 equal an equal arm that would you say an
00:01:22.059 00:01:22.069 equal transition we don't want to see a
00:01:25.330 00:01:25.340 line so I'm gonna be adjusting it out
00:01:29.050 00:01:29.060 there
00:01:30.609 00:01:30.619 and
00:01:33.230 00:01:33.240 bravery that I have here with the
00:01:35.540 00:01:35.550 regulator attached
00:01:39.030 00:01:39.040 pretty much already set to
00:01:43.340 00:01:43.350 20 bars 20 psi actually I mean two barns
00:01:47.420 00:01:47.430 to be exact
00:01:50.170 00:01:50.180 when I'm spraying it drops down to 20
00:01:53.260 00:01:53.270 psi so that I have that pressure
00:01:59.620 00:01:59.630 spraying
00:02:04.850 00:02:04.860 it's understanding but anyways we're
00:02:08.480 00:02:08.490 going to brush this coil out make sure
00:02:10.850 00:02:10.860 we clean it out before we actually spray
00:02:13.520 00:02:13.530 it
00:02:16.830 00:02:16.840 poor shot
00:02:58.410 00:02:58.420 AC power and comfort so mark pretty much
00:03:03.420 00:03:03.430 wrapped up and we're done
00:03:09.530 00:03:09.540 freshers are normal again this was only
00:03:13.230 00:03:13.240 done on the outside of the coil because
00:03:15.210 00:03:15.220 the thing is the outside of the coil is
00:03:17.970 00:03:17.980 normally where the corrosion takes place
00:03:21.510 00:03:21.520 first because that is the inlet side of
00:03:24.210 00:03:24.220 the air coming in as well as rain etc
00:03:29.960 00:03:29.970 the reason for this was do was to
00:03:33.510 00:03:33.520 protect the coil to extend the life of
00:03:37.110 00:03:37.120 the coil as well as the life of the unit
00:03:40.710 00:03:40.720 as of right now has a new convinced of
00:03:43.320 00:03:43.330 coil new compressors and the original
00:03:47.760 00:03:47.770 r22 in this system
00:03:50.720 00:03:50.730 because I encountered an issue with the
00:03:52.790 00:03:52.800 new 22 feet where it basically had lost
00:03:58.820 00:03:58.830 one of its blends and wasn't performing
00:04:01.220 00:04:01.230 right so I had recovered the whole
00:04:02.660 00:04:02.670 refrigerant and add the original hcfc
00:04:07.760 00:04:07.770 r22 here
00:04:10.420 00:04:10.430 anyways to make the loan story start AC
00:04:13.059 00:04:13.069 power comfort again this is a coating on
00:04:16.150 00:04:16.160 the condenser coil coatings can also be
00:04:19.420 00:04:19.430 done on evaporator coils coating can
00:04:21.879 00:04:21.889 also be done on chillers if you have any
00:04:24.970 00:04:24.980 type of issues where you would like to
00:04:28.350 00:04:28.360 protect that issues but more or less you
00:04:30.790 00:04:30.800 guys would like to extend the life of
00:04:32.200 00:04:32.210 your system on the coil chillers cooling
00:04:35.200 00:04:35.210 towers or any type of leaks as well if
00:04:37.659 00:04:37.669 you have a cooling tower leak or it
00:04:39.250 00:04:39.260 needs to be recoded
00:04:40.860 00:04:40.870 resurfaced and the inside of the basin
00:04:43.120 00:04:43.130 AC power in comfort pretty much can
00:04:46.719 00:04:46.729 handle that you can visit my website at
00:04:49.320 00:04:49.330 www.att.com/biz
00:04:56.350 00:04:56.360 again I'm Omar and they keep appealing
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12

Phone: +7 343 216 77 75

E-mail: info@lotus1.ru

Sales phone

Russia: +7 343 216 77 75

WhatsApp: +79122710308