00:00:15.830 okay 00:00:17.66000:00:17.670 ac pal we're in comfort well he have 00:00:21.32000:00:21.330 this the Commons but today we're on unit 00:00:24.10900:00:24.119 number two 00:00:25.97000:00:25.980 previously when the coil was installed 00:00:30.94000:00:30.950 we'll be spray-painting with an epoxy 00:00:33.10000:00:33.110 coating protect the coil today I pretty 00:00:38.08000:00:38.090 much have everything set off 00:00:41.34900:00:41.359 take off that we don't get anything on 00:00:44.52900:00:44.539 the accident panels 00:00:46.04900:00:46.059 others might think differently I would 00:00:49.29900:00:49.309 prefer to do it when the fans are on 00:00:50.91900:00:50.929 especially when we're on the roof due to 00:00:53.59000:00:53.600 the fact that there's there's heavy 00:00:55.81000:00:55.820 winds so I would prefer that when I 00:00:57.84900:00:57.859 spray the actual epoxy coating it goes 00:01:02.31900:01:02.329 through and pretty much gets expelled 00:01:06.49000:01:06.500 through the top of the actual gets 00:01:08.35000:01:08.360 exhausted out through the top of the 00:01:10.27000:01:10.280 condenser even though some particles 00:01:12.42900:01:12.439 might get onto the blade etc but that's 00:01:15.13000:01:15.140 just my new Barry my new then like an 00:01:18.21900:01:18.229 equal an equal arm that would you say an 00:01:22.05900:01:22.069 equal transition we don't want to see a 00:01:25.33000:01:25.340 line so I'm gonna be adjusting it out 00:01:29.05000:01:29.060 there 00:01:30.60900:01:30.619 and 00:01:33.23000:01:33.240 bravery that I have here with the 00:01:35.54000:01:35.550 regulator attached 00:01:39.03000:01:39.040 pretty much already set to 00:01:43.34000:01:43.350 20 bars 20 psi actually I mean two barns 00:01:47.42000:01:47.430 to be exact 00:01:50.17000:01:50.180 when I'm spraying it drops down to 20 00:01:53.26000:01:53.270 psi so that I have that pressure 00:01:59.62000:01:59.630 spraying 00:02:04.85000:02:04.860 it's understanding but anyways we're 00:02:08.48000:02:08.490 going to brush this coil out make sure 00:02:10.85000:02:10.860 we clean it out before we actually spray 00:02:13.52000:02:13.530 it 00:02:16.83000:02:16.840 poor shot 00:02:58.41000:02:58.420 AC power and comfort so mark pretty much 00:03:03.42000:03:03.430 wrapped up and we're done 00:03:09.53000:03:09.540 freshers are normal again this was only 00:03:13.23000:03:13.240 done on the outside of the coil because 00:03:15.21000:03:15.220 the thing is the outside of the coil is 00:03:17.97000:03:17.980 normally where the corrosion takes place 00:03:21.51000:03:21.520 first because that is the inlet side of 00:03:24.21000:03:24.220 the air coming in as well as rain etc 00:03:29.96000:03:29.970 the reason for this was do was to 00:03:33.51000:03:33.520 protect the coil to extend the life of 00:03:37.11000:03:37.120 the coil as well as the life of the unit 00:03:40.71000:03:40.720 as of right now has a new convinced of 00:03:43.32000:03:43.330 coil new compressors and the original 00:03:47.76000:03:47.770 r22 in this system 00:03:50.72000:03:50.730 because I encountered an issue with the 00:03:52.79000:03:52.800 new 22 feet where it basically had lost 00:03:58.82000:03:58.830 one of its blends and wasn't performing 00:04:01.22000:04:01.230 right so I had recovered the whole 00:04:02.66000:04:02.670 refrigerant and add the original hcfc 00:04:07.76000:04:07.770 r22 here 00:04:10.42000:04:10.430 anyways to make the loan story start AC 00:04:13.05900:04:13.069 power comfort again this is a coating on 00:04:16.15000:04:16.160 the condenser coil coatings can also be 00:04:19.42000:04:19.430 done on evaporator coils coating can 00:04:21.87900:04:21.889 also be done on chillers if you have any 00:04:24.97000:04:24.980 type of issues where you would like to 00:04:28.35000:04:28.360 protect that issues but more or less you 00:04:30.79000:04:30.800 guys would like to extend the life of 00:04:32.20000:04:32.210 your system on the coil chillers cooling 00:04:35.20000:04:35.210 towers or any type of leaks as well if 00:04:37.65900:04:37.669 you have a cooling tower leak or it 00:04:39.25000:04:39.260 needs to be recoded 00:04:40.86000:04:40.870 resurfaced and the inside of the basin 00:04:43.12000:04:43.130 AC power in comfort pretty much can 00:04:46.71900:04:46.729 handle that you can visit my website at 00:04:49.32000:04:49.330 www.att.com/biz 00:04:56.35000:04:56.360 again I'm Omar and they keep appealing
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12