National Grid - Condensing Boilers

WEBVTT
Kind: captions
Language: en

00:00:04.620
properly designed hydronic systems
00:00:06.720 00:00:06.730 provide clean energy-efficient comfort
00:00:09.450 00:00:09.460 in a versatile package but the
00:00:11.759 00:00:11.769 efficiency of a space heating hydronic
00:00:13.470 00:00:13.480 system is only as good as the boiler
00:00:15.299 00:00:15.309 that powers the whole process if we look
00:00:17.999 00:00:18.009 inside a conventional non condensing
00:00:19.859 00:00:19.869 boiler we see that combusted gas hits
00:00:21.870 00:00:21.880 the heat exchanger which raises the
00:00:23.729 00:00:23.739 water temperature before it goes out
00:00:25.170 00:00:25.180 into the system however there's also a
00:00:27.749 00:00:27.759 lot of extra heat that has sucked out
00:00:29.370 00:00:29.380 the exhaust flue with as much as 30
00:00:31.260 00:00:31.270 percent of the energy being wasted
00:00:32.819 00:00:32.829 replacing the conventional boiler with a
00:00:34.920 00:00:34.930 condensing boiler can add efficiency to
00:00:37.080 00:00:37.090 any hydronic system condensing boilers
00:00:39.419 00:00:39.429 have two heat exchangers the first like
00:00:42.000 00:00:42.010 the non condensing boiler is heated by
00:00:43.799 00:00:43.809 the gas burner the second captures the
00:00:46.139 00:00:46.149 excess exhaust gas heat from the primary
00:00:48.329 00:00:48.339 exchanger the heat that is normally
00:00:49.979 00:00:49.989 exhausted is waste the high-temperature
00:00:52.110 00:00:52.120 water vapour in the exhaust gas
00:00:53.759 00:00:53.769 condenses into liquid water releasing a
00:00:56.310 00:00:56.320 large amount of heat that is transferred
00:00:57.599 00:00:57.609 to the cool water as it first enters
00:00:59.939 00:00:59.949 through the secondary heat exchanger the
00:01:01.950 00:01:01.960 transfer it pre heats the water in the
00:01:03.599 00:01:03.609 system before it's brought up to the
00:01:05.340 00:01:05.350 desired temperature by the primary heat
00:01:07.290 00:01:07.300 exchanger by preheating the entering
00:01:09.810 00:01:09.820 cool water the primary heat exchanger
00:01:11.969 00:01:11.979 has to do less work to heat the water to
00:01:14.130 00:01:14.140 the final temperature meanwhile the
00:01:16.440 00:01:16.450 exhaust gas condensate harmlessly drains
00:01:18.569 00:01:18.579 out of the system reusing the exhaust
00:01:21.389 00:01:21.399 gas heat results in far lower flue
00:01:23.580 00:01:23.590 temperatures than those coming from
00:01:25.020 00:01:25.030 conventional boilers and that extra heat
00:01:27.840 00:01:27.850 coming out of the flue of conventional
00:01:29.310 00:01:29.320 boilers is wasted energy condensing
00:01:32.249 00:01:32.259 boiler efficiency ranges from 84 to 98%
00:01:35.580 00:01:35.590 depending on conditions new conventional
00:01:38.580 00:01:38.590 boilers max out at 82% while older units
00:01:41.940 00:01:41.950 can fall as low as 65%
00:01:44.300 00:01:44.310 according to the Building Research
00:01:45.959 00:01:45.969 Establishment or BR eak in the UK
00:01:48.800 00:01:48.810 condensing boilers are more efficient
00:01:50.880 00:01:50.890 than standard units in every operating
00:01:52.889 00:01:52.899 condition that's a bold statement but
00:01:56.370 00:01:56.380 one that makes perfect sense when you
00:01:57.779 00:01:57.789 consider the ingenious design of the
00:01:59.580 00:01:59.590 condensing boiler
00:02:01.390 00:02:01.400 you