New Bosch Floor Standing Boilers

WEBVTT
Kind: captions
Language: en

00:00:02.600
so my name is mark Ava and I'm a
00:00:04.820 00:00:04.830 national sales manager for Bosch thermo
00:00:07.430 00:00:07.440 technologies in North America so
00:00:09.410 00:00:09.420 covering both the US and Canadian
00:00:11.120 00:00:11.130 markets Bosch thermo technologies North
00:00:13.730 00:00:13.740 America is part of the Robert Bosch
00:00:15.049 00:00:15.059 corporation what we're talking about
00:00:16.700 00:00:16.710 today is the Greenstar floor boiler
00:00:19.040 00:00:19.050 what's unique about is we've designed
00:00:21.140 00:00:21.150 this specifically for the North American
00:00:23.179 00:00:23.189 market as a replacement product it would
00:00:26.089 00:00:26.099 kind of took a look at all of the the
00:00:28.040 00:00:28.050 components or the aspects of the
00:00:29.810 00:00:29.820 installation from the footprint to the
00:00:33.979 00:00:33.989 piping to wiring to venting and try to
00:00:36.200 00:00:36.210 simplify that installation as much as
00:00:39.200 00:00:39.210 possible so we've done things in terms
00:00:41.660 00:00:41.670 of the wire and we've relocated all the
00:00:44.450 00:00:44.460 wiring towards the back of the boiler
00:00:45.830 00:00:45.840 the easy access the Installer doesn't
00:00:48.799 00:00:48.809 have to access inside the boiler to do
00:00:51.920 00:00:51.930 the wiring through the piping one of the
00:00:53.869 00:00:53.879 key features is a built-in hydraulic
00:00:56.029 00:00:56.039 separator into the boiler so the supply
00:00:58.610 00:00:58.620 and return piping that you see coming
00:01:00.410 00:01:00.420 out of the boiler is a direct connect
00:01:02.299 00:01:02.309 into existing system so the installer
00:01:04.460 00:01:04.470 doesn't have to pipe a primary secondary
00:01:06.440 00:01:06.450 or you use a low loss header to get
00:01:10.969 00:01:10.979 hydraulically separate the boiler from
00:01:12.530 00:01:12.540 the system so it just makes the
00:01:13.880 00:01:13.890 installation easier faster more
00:01:16.600 00:01:16.610 cost-effective we've also launched at
00:01:20.149 00:01:20.159 the same time some control options again
00:01:23.390 00:01:23.400 so you can start out with a base version
00:01:25.910 00:01:25.920 of the boiler with very simple
00:01:27.109 00:01:27.119 controlling no programming required
00:01:29.830 00:01:29.840 upgrade that to an outdoor reset control
00:01:33.410 00:01:33.420 that gives you considerable more
00:01:34.910 00:01:34.920 functionality and then take that to a
00:01:38.410 00:01:38.420 zoning control system that is that
00:01:41.600 00:01:41.610 automatically adapts to the to the
00:01:44.149 00:01:44.159 system so it really gives a contract is
00:01:46.010 00:01:46.020 a lot of a lot of flexibility a lot of
00:01:48.920 00:01:48.930 options for their customers to maximize
00:01:51.950 00:01:51.960 efficiency maximize comfort level in the
00:01:54.859 00:01:54.869 homes so with the Greenstar floor and
00:01:57.560 00:01:57.570 wall boiler you've got the ability to
00:01:59.690 00:01:59.700 vent with GBC with CPVC
00:02:02.149 00:02:02.159 but we'll ulc 6:36 with polypropylene
00:02:06.800 00:02:06.810 with flexible polypropylene 2 inch 3
00:02:10.609 00:02:10.619 inch so this you know is
00:02:11.900 00:02:11.910 any options as as possible into venting
00:02:14.720 00:02:14.730 the product so we offer a limited
00:02:16.310 00:02:16.320 lifetime warranty on the heat exchanger
00:02:18.160 00:02:18.170 itself one of the key features to our
00:02:21.440 00:02:21.450 heat exchanger is that it has a
00:02:23.230 00:02:23.240 polymerized coating on the flue gas side
00:02:25.700 00:02:25.710 it's a fancy term but really what it
00:02:28.100 00:02:28.110 means is it's it's it protects the
00:02:30.830 00:02:30.840 boiler from scale formation and build up
00:02:33.260 00:02:33.270 on the heat exchanger which reduces the
00:02:36.350 00:02:36.360 the maintenance requirements so cleaning
00:02:39.080 00:02:39.090 this boiler - we recommend every five
00:02:42.050 00:02:42.060 years or so most manufacturers are
00:02:44.300 00:02:44.310 recommending annual maintenance some of
00:02:46.010 00:02:46.020 our products we recommend annual
00:02:47.510 00:02:47.520 maintenance so it's an advancement in
00:02:49.130 00:02:49.140 technology and because of that the
00:02:52.010 00:02:52.020 boiler stays cleaner for longer periods
00:02:53.960 00:02:53.970 of time your efficiencies state stay
00:02:56.600 00:02:56.610 high for longer periods of time and it
00:02:59.090 00:02:59.100 reduces on the wear and tear on system
00:03:01.100 00:03:01.110 components so we also offer a five year
00:03:03.650 00:03:03.660 parts and labor warranty right out of
00:03:05.630 00:03:05.640 the box and we handle that warranty it's
00:03:07.730 00:03:07.740 not a third-party underwriter it's
00:03:10.040 00:03:10.050 handled by Bosch directly so it really
00:03:12.350 00:03:12.360 is the strongest warranty in the in the
00:03:14.690 00:03:14.700 hydronic industry for a boiler
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12

Phone: +7 343 216 77 75

E-mail: info@lotus1.ru

Sales phone

Russia: +7 343 216 77 75

WhatsApp: +79122710308