No hot water from your boiler What to look for and how to fix it.

WEBVTT
Kind: captions
Language: en

00:00:00.269
hire one Allegan had a few inquiries
00:00:03.260 00:00:03.270 about problems with heating and hot
00:00:05.630 00:00:05.640 water again and this one conserves a hot
00:00:07.670 00:00:07.680 one
00:00:08.650 00:00:08.660 where people are getting heating again
00:00:12.140 00:00:12.150 not war at all this one concerns not
00:00:15.589 00:00:15.599 convey this is a conventional system
00:00:17.920 00:00:17.930 combi boiler is something else
00:00:20.029 00:00:20.039 altogether but it's fun concerns a hot
00:00:21.890 00:00:21.900 water tank so you people have been right
00:00:25.130 00:00:25.140 and say yeah can its Bo I've got heating
00:00:27.620 00:00:27.630 but there's just no water tank at all
00:00:29.450 00:00:29.460 well there are a couple of things that
00:00:31.550 00:00:31.560 you know this this can be you've
00:00:33.020 00:00:33.030 actually turned you where you're getting
00:00:34.310 00:00:34.320 heating already so you must have power
00:00:35.930 00:00:35.940 and your boiler must be running there's
00:00:37.910 00:00:37.920 not much else to check but I can tell
00:00:40.520 00:00:40.530 you the two main things to check and the
00:00:42.830 00:00:42.840 first one is this if you like the follow
00:00:44.540 00:00:44.550 me and it's quite simply one really
00:00:46.549 00:00:46.559 because on the band or singer the tank
00:00:49.970 00:00:49.980 is you might call it is a thermostat and
00:00:54.279 00:00:54.289 thermostat counted there I've got mine
00:00:59.090 00:00:59.100 rather higher because I've got my
00:01:01.849 00:01:01.859 daughter's down we need a lot of water
00:01:03.260 00:01:03.270 moment nobody else is set a sixty
00:01:04.910 00:01:04.920 degrees okay but you can just click it a
00:01:07.520 00:01:07.530 little bit more to make sure it turns on
00:01:09.410 00:01:09.420 Tony up to 70 to make sure that the
00:01:12.469 00:01:12.479 whole thing clicks on and gets you some
00:01:14.390 00:01:14.400 hot water there now that could be gone
00:01:18.499 00:01:18.509 but more than likely I will say it
00:01:21.320 00:01:21.330 probably user now likely suspicion is
00:01:24.710 00:01:24.720 this thing here and it's called of a
00:01:27.200 00:01:27.210 motorized valve nearly rev two of these
00:01:31.219 00:01:31.229 or just one I'm going to show you my one
00:01:35.289 00:01:35.299 and I've got one located there near it
00:01:39.830 00:01:39.840 is I'm you may have to and normally it's
00:01:42.289 00:01:42.299 the ones with two that go wrong because
00:01:44.210 00:01:44.220 the three wave hours tend to let hot
00:01:46.490 00:01:46.500 water through most of time anyway but if
00:01:49.580 00:01:49.590 you've got two separate motorized valve
00:01:51.260 00:01:51.270 you may find that the hot water one is
00:01:54.020 00:01:54.030 gone dead by that I mean it's not open
00:01:57.050 00:01:57.060 up and allow in order to get to the
00:01:58.490 00:01:58.500 whole routine now on the side of this
00:02:00.770 00:02:00.780 valve there is it leaver um just grab
00:02:03.859 00:02:03.869 the camera a second let's show you that
00:02:05.300 00:02:05.310 little lever you can see at the other
00:02:07.340 00:02:07.350 side okay just pull that lever back and
00:02:11.270 00:02:11.280 then you will find that the
00:02:13.280 00:02:13.290 opens and you'll have manual operation
00:02:16.190 00:02:16.200 you'll get hot water and it will get
00:02:18.110 00:02:18.120 your by for a while until you want to
00:02:20.449 00:02:20.459 renew that valve because it fairly
00:02:22.190 00:02:22.200 expensive job that normally is the job
00:02:25.130 00:02:25.140 there is one last thing to check some
00:02:28.190 00:02:28.200 older systems like in this system the
00:02:31.699 00:02:31.709 flow pipe from the boiler goes up across
00:02:33.470 00:02:33.480 the roof it goes through the attic and
00:02:35.990 00:02:36.000 drops down into the air in cupboard and
00:02:39.020 00:02:39.030 if you able that type of system if your
00:02:41.270 00:02:41.280 little F&E tankers run dry then that
00:02:44.929 00:02:44.939 pipe line up on top of the ceiling air
00:02:46.670 00:02:46.680 has probably got airing in because it's
00:02:48.949 00:02:48.959 run dry so the very last thing to check
00:02:50.869 00:02:50.879 is to go up in the lot and make sure
00:02:53.059 00:02:53.069 that if any tank the field expansion has
00:02:55.490 00:02:55.500 gone ruin it just push the ball up
00:02:57.649 00:02:57.659 and down if it looks dry just wiggly
00:02:59.240 00:02:59.250 like this and wash it pouring and fill
00:03:02.240 00:03:02.250 it up and make sure that it's the tanks
00:03:04.610 00:03:04.620 full after day it should go I'm pretty
00:03:07.309 00:03:07.319 certain you'll get result from that one
00:03:09.530 00:03:09.540 that's usually how to cure problems if
00:03:12.530 00:03:12.540 you haven't got any hot water when you
00:03:15.170 00:03:15.180 put yeah boiler on okay now and that's
00:03:18.170 00:03:18.180 about it a fairly simple one get back to
00:03:20.420 00:03:20.430 me there's any buttons with it if you're
00:03:21.770 00:03:21.780 still having trouble anyway thanks for
00:03:23.750 00:03:23.760 much watching don't and Foley for more
00:03:25.490 00:03:25.500 videos