/ News & Press / Video / Operator Training _ CoalSAFE, Airlock _ ENGLISH
Operator Training _ CoalSAFE, Airlock _ ENGLISH
WEBVTT Kind: captions Language: en
00:00:01.630 you 00:00:06.46000:00:06.470 welcome to the mine arc systems operator 00:00:09.61900:00:09.629 training video this short presentation 00:00:12.60900:00:12.619 will show you how to operate a monarch 00:00:15.76900:00:15.779 systems coal safe refuge step one remove 00:00:20.80000:00:20.810 gas monitors break seal on the gas 00:00:24.83000:00:24.840 monitor storage located on the front 00:00:27.38000:00:27.390 wall and remove gas monitors if gas 00:00:30.92000:00:30.930 monitors are not present proceed to step 00:00:33.83000:00:33.840 two step to open entry door and enter 00:00:38.86900:00:38.879 airlock before entering the airlock 00:00:41.77900:00:41.789 ensure it is vacant by looking through 00:00:44.50900:00:44.519 the portal window if airlock is occupied 00:00:47.56900:00:47.579 wait until it is vacant and the internal 00:00:50.47900:00:50.489 door is closed enter the airlock by 00:00:54.02000:00:54.030 rotating the handles to the vertical 00:00:55.91000:00:55.920 unlock position make certain to take 00:00:59.41900:00:59.429 both gasp monitors into the airlock if 00:01:02.14900:01:02.159 carrying to secure the door rotate the 00:01:05.71900:01:05.729 handles to the horizontal lock position 00:01:10.42000:01:10.430 step 3 commence airlock flushing turn 00:01:15.05000:01:15.060 pilot switch on an open ball valve to 00:01:18.20000:01:18.210 commence flushing step 4 activate with 00:01:22.96900:01:22.979 pump gas monitor remove the whiff pump 00:01:26.63000:01:26.640 gas monitor from its storage case 00:01:29.20000:01:29.210 activate with pump gas monitor by 00:01:32.12000:01:32.130 pulling battery tab then pushing and 00:01:36.08000:01:36.090 holding the power button place your hand 00:01:40.16000:01:40.170 over the pump when directed by the gas 00:01:43.03900:01:43.049 monitor step 5 flush airlock remove the 00:01:48.56000:01:48.570 4 minute timer from the gas monitor 00:01:50.95900:01:50.969 holder flush the airlock for 4 minutes 00:01:53.95900:01:53.969 or until co is less than 25 ppm step 6 00:02:00.31900:02:00.329 leave with pump gas monitor in gas 00:02:03.80000:02:03.810 monitor holder 00:02:05.51000:02:05.520 close ball valve and leave with pump gas 00:02:08.57000:02:08.580 monitor and timer in gas monitor holder 00:02:11.80900:02:11.819 for next occupants entering airlock step 00:02:15.97900:02:15.989 7 open airlock door and enter main 00:02:19.46000:02:19.470 refuge open airlock door by rotating the 00:02:23.21000:02:23.220 handles to the vertical unlock position 00:02:25.40000:02:25.410 and enter the main refuge with the 00:02:28.58000:02:28.590 without gas pump monitor close and seal 00:02:32.78000:02:32.790 airlock door to secure the door rotate 00:02:36.65000:02:36.660 the handles to the horizontal lock 00:02:39.17000:02:39.180 position please note when the refuge is 00:02:42.62000:02:42.630 fully occupied the airlock can remain 00:02:45.41000:02:45.420 open do not remove SCS are until 00:02:50.05900:02:50.069 scrubber system and oxygen supply are 00:02:52.88000:02:52.890 activated and gases are within 00:02:55.10000:02:55.110 acceptable concentration as indicated by 00:02:58.16000:02:58.170 gas monitor refer to the bottom of the 00:03:02.93000:03:02.940 life-support settings table for 00:03:04.75900:03:04.769 acceptable gas concentrations step 8 00:03:08.39000:03:08.400 install Marcus orb co2 cartridges remove 00:03:12.94900:03:12.959 three Marcus orb co2 cartridges from 00:03:15.94900:03:15.959 their storage location remove cartridges 00:03:19.06900:03:19.079 from their packaging and place on top of 00:03:21.92000:03:21.930 scrubber system the cartridges will slot 00:03:24.59000:03:24.600 into place with the rubber seals on the 00:03:27.25900:03:27.269 bottom side replace all cartridges when 00:03:30.65000:03:30.660 co2 reaches 1 percent or as indicated by 00:03:34.22000:03:34.230 the life-support settings table located 00:03:36.80000:03:36.810 on the refuge wall step 9 install Marcus 00:03:41.78000:03:41.790 orb Co cartridge if carbon monoxide 00:03:44.78000:03:44.790 concentration reaches 25 ppm remove 00:03:48.77000:03:48.780 Marcus orb Co cartridge from its storage 00:03:51.80000:03:51.810 location and packaging remove one co2 00:03:56.05900:03:56.069 cartridge from top of scrubber and 00:03:58.09900:03:58.109 replace with Co cartridge use only as 00:04:01.69900:04:01.709 needed stepped in turn on master control 00:04:06.19900:04:06.209 valve turn on master control valve 00:04:09.05000:04:09.060 counterclockwise located on the back 00:04:12.05000:04:12.060 wall 00:04:13.19000:04:13.200 step 11 turn on temperature control 00:04:16.55000:04:16.560 valves turn on all temperature control 00:04:19.52000:04:19.530 valves TCV one two three and four for 00:04:24.26000:04:24.270 one minute to start scrubber system step 00:04:29.75000:04:29.760 12 turn off temperature control valves 00:04:32.81000:04:32.820 turn off temperature control valves TCV 00:04:36.65000:04:36.660 two three and four only caution TCV one 00:04:42.29000:04:42.300 remains on at all times unless internal 00:04:45.44000:04:45.450 temperature is below 65 degrees 00:04:47.84000:04:47.850 Fahrenheit or 18 degrees Celsius cycle 00:04:52.07000:04:52.080 TC v1 when co2 reaches one percent by 00:04:56.03000:04:56.040 turning on for 30 minutes repeat as 00:04:59.96000:04:59.970 needed step 13 monitor wet bulb 00:05:04.67000:05:04.680 temperature turn on TCB two three and 00:05:08.93000:05:08.940 four individually to increase cooling of 00:05:12.26000:05:12.270 wet bulb temperature exceeds 84 degrees 00:05:14.87000:05:14.880 Fahrenheit or 28 degrees Celsius observe 00:05:19.85000:05:19.860 temperature and relative humidity on 00:05:21.71000:05:21.720 hygrometer and refer to wet bulb 00:05:23.96000:05:23.970 temperature chart on refuge wall caution 00:05:27.65000:05:27.660 using additional TC vs when not needed 00:05:30.89000:05:30.900 will consume additional cooling 00:05:33.35000:05:33.360 refrigerant and potentially reduce 00:05:35.77900:05:35.789 scrubber operating time to less than 96 00:05:39.11000:05:39.120 hours step 14 install and adjust o2 flow 00:05:44.57000:05:44.580 meter remove flow meter and gloves from 00:05:48.26000:05:48.270 sealed case put on nitrile gloves and 00:05:52.52000:05:52.530 connect flow meter to Quick Connect 00:05:54.62000:05:54.630 coupling 00:05:56.39900:05:56.409 adjust flowmeter to 0.5 liters per 00:06:00.20900:06:00.219 occupant by rotating knob counter 00:06:03.14900:06:03.159 clockwise see life support settings 00:06:06.47900:06:06.489 table on refuge wall for flow rates step 00:06:10.16900:06:10.179 15 gas monitoring retrieve with pump gas 00:06:14.60900:06:14.619 monitor marker and timer from air lock 00:06:18.11900:06:18.129 and turn off by pushing the power button 00:06:20.98900:06:20.999 use for external monitoring only use the 00:06:25.32000:06:25.330 without pump gas monitor to monitor 00:06:27.62900:06:27.639 internal o2 Co to Co and ch4 adjust 00:06:34.10900:06:34.119 oxygen flow meter and replace marcos orb 00:06:36.95900:06:36.969 co2 cartridges when gases are outside 00:06:40.25900:06:40.269 acceptable gas concentrations refer to 00:06:43.82900:06:43.839 the bottom of the life-support settings 00:06:45.74900:06:45.759 table on the refuge wall for a guide on 00:06:48.41900:06:48.429 reading alarms and ensuring that 00:06:50.42900:06:50.439 breathing air quality is maintained gas 00:06:55.01900:06:55.029 testing guide using the timer and marker 00:06:59.04000:06:59.050 record gas concentrations and wet bulb 00:07:02.45900:07:02.469 temperature hourly on the charts located 00:07:05.54900:07:05.559 at the rear of the photographic 00:07:07.35000:07:07.360 operating procedures insufficient oxygen 00:07:11.27900:07:11.289 level in the refuge if oxygen level is 00:07:15.56900:07:15.579 less than 18.5 percent adjust the oxygen 00:07:19.70900:07:19.719 flow meter up accordingly high oxygen 00:07:24.14900:07:24.159 concentration detected in the refuge if 00:07:27.91900:07:27.929 oxygen concentration exceeds 23% turn 00:07:32.48900:07:32.499 flow meter off ensure airlock doors open 00:07:36.56900:07:36.579 an open ball valve to commence airlock 00:07:39.60000:07:39.610 flushing flush until oxygen 00:07:41.95900:07:41.969 concentration inside main refuge is less 00:07:45.50900:07:45.519 than twenty two percent turn flow meter 00:07:48.74900:07:48.759 on when oxygen concentration is twenty 00:07:51.98900:07:51.999 percent excess carbon dioxide detected 00:07:56.06900:07:56.079 in refuge 00:07:57.87900:07:57.889 if carbon dioxide level exceeds 1% 00:08:01.36000:08:01.370 remove the Marcus orb co2 cartridges 00:08:04.65900:08:04.669 from the scrubber and replace with new 00:08:06.96900:08:06.979 cartridges refer to the life support 00:08:09.99900:08:10.009 settings table for approximate Marcus 00:08:12.48900:08:12.499 orb co2 cartridge replacement duration 00:08:15.80900:08:15.819 step 16 emergency gas bypass system the 00:08:21.27900:08:21.289 emergency gas bypass system is a safety 00:08:24.04000:08:24.050 feature designed to extend the duration 00:08:26.01900:08:26.029 of the refuge the system must only be 00:08:29.01900:08:29.029 activated after 96 hours of normal 00:08:32.50000:08:32.510 operation before activating the system 00:08:35.64900:08:35.659 the high pressure gauge on the scrubber 00:08:37.87000:08:37.880 must read below 400 psi or the scrubber 00:08:42.69900:08:42.709 air flow with altie CVS on must be too 00:08:47.05000:08:47.060 low to maintain a co2 concentration 00:08:50.31900:08:50.329 below 1% to activate the system ensure 00:08:54.75900:08:54.769 all T Seavey's are on open the emergency 00:08:58.48000:08:58.490 gas bypass valve located on the left 00:09:01.84000:09:01.850 hand side of the scrubber system rotate 00:09:05.29000:09:05.300 knob counterclockwise until low pressure 00:09:08.31900:09:08.329 gauge reads between 30 to 50 psi use the 00:09:13.72000:09:13.730 lowest pressure that allows gas 00:09:15.67000:09:15.680 concentration to remain at acceptable 00:09:18.13000:09:18.140 levels for further information refer to 00:09:21.91000:09:21.920 general overview and operating 00:09:23.88900:09:23.899 procedures the most important thing you 00:09:26.94900:09:26.959 can do now is to make sure your refuge 00:09:29.82900:09:29.839 is maintained and good operational order 00:09:32.62000:09:32.630 so in the unfortunate event you need to 00:09:35.38000:09:35.390 use the refuge you can feel safe knowing 00:09:38.11000:09:38.120 that it is ready for use this can be 00:09:40.90000:09:40.910 accomplished through weekly checks and 00:09:42.67000:09:42.680 regular servicing which can be carried 00:09:45.51900:09:45.529 out by my narc systems for further 00:09:48.25000:09:48.260 details or if you have any queries 00:09:50.68000:09:50.690 regarding the operation of a coal safe 00:09:53.11000:09:53.120 refuge please contact my narc systems or 00:09:56.50000:09:56.510 visit the website at WWE com 00:10:02.30000:10:02.310
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12