Operator Training _ CoalSAFE, Airlock _ ENGLISH

WEBVTT
Kind: captions
Language: en

00:00:01.630
you
00:00:06.460 00:00:06.470 welcome to the mine arc systems operator
00:00:09.619 00:00:09.629 training video this short presentation
00:00:12.609 00:00:12.619 will show you how to operate a monarch
00:00:15.769 00:00:15.779 systems coal safe refuge step one remove
00:00:20.800 00:00:20.810 gas monitors break seal on the gas
00:00:24.830 00:00:24.840 monitor storage located on the front
00:00:27.380 00:00:27.390 wall and remove gas monitors if gas
00:00:30.920 00:00:30.930 monitors are not present proceed to step
00:00:33.830 00:00:33.840 two step to open entry door and enter
00:00:38.869 00:00:38.879 airlock before entering the airlock
00:00:41.779 00:00:41.789 ensure it is vacant by looking through
00:00:44.509 00:00:44.519 the portal window if airlock is occupied
00:00:47.569 00:00:47.579 wait until it is vacant and the internal
00:00:50.479 00:00:50.489 door is closed enter the airlock by
00:00:54.020 00:00:54.030 rotating the handles to the vertical
00:00:55.910 00:00:55.920 unlock position make certain to take
00:00:59.419 00:00:59.429 both gasp monitors into the airlock if
00:01:02.149 00:01:02.159 carrying to secure the door rotate the
00:01:05.719 00:01:05.729 handles to the horizontal lock position
00:01:10.420 00:01:10.430 step 3 commence airlock flushing turn
00:01:15.050 00:01:15.060 pilot switch on an open ball valve to
00:01:18.200 00:01:18.210 commence flushing step 4 activate with
00:01:22.969 00:01:22.979 pump gas monitor remove the whiff pump
00:01:26.630 00:01:26.640 gas monitor from its storage case
00:01:29.200 00:01:29.210 activate with pump gas monitor by
00:01:32.120 00:01:32.130 pulling battery tab then pushing and
00:01:36.080 00:01:36.090 holding the power button place your hand
00:01:40.160 00:01:40.170 over the pump when directed by the gas
00:01:43.039 00:01:43.049 monitor step 5 flush airlock remove the
00:01:48.560 00:01:48.570 4 minute timer from the gas monitor
00:01:50.959 00:01:50.969 holder flush the airlock for 4 minutes
00:01:53.959 00:01:53.969 or until co is less than 25 ppm step 6
00:02:00.319 00:02:00.329 leave with pump gas monitor in gas
00:02:03.800 00:02:03.810 monitor holder
00:02:05.510 00:02:05.520 close ball valve and leave with pump gas
00:02:08.570 00:02:08.580 monitor and timer in gas monitor holder
00:02:11.809 00:02:11.819 for next occupants entering airlock step
00:02:15.979 00:02:15.989 7 open airlock door and enter main
00:02:19.460 00:02:19.470 refuge open airlock door by rotating the
00:02:23.210 00:02:23.220 handles to the vertical unlock position
00:02:25.400 00:02:25.410 and enter the main refuge with the
00:02:28.580 00:02:28.590 without gas pump monitor close and seal
00:02:32.780 00:02:32.790 airlock door to secure the door rotate
00:02:36.650 00:02:36.660 the handles to the horizontal lock
00:02:39.170 00:02:39.180 position please note when the refuge is
00:02:42.620 00:02:42.630 fully occupied the airlock can remain
00:02:45.410 00:02:45.420 open do not remove SCS are until
00:02:50.059 00:02:50.069 scrubber system and oxygen supply are
00:02:52.880 00:02:52.890 activated and gases are within
00:02:55.100 00:02:55.110 acceptable concentration as indicated by
00:02:58.160 00:02:58.170 gas monitor refer to the bottom of the
00:03:02.930 00:03:02.940 life-support settings table for
00:03:04.759 00:03:04.769 acceptable gas concentrations step 8
00:03:08.390 00:03:08.400 install Marcus orb co2 cartridges remove
00:03:12.949 00:03:12.959 three Marcus orb co2 cartridges from
00:03:15.949 00:03:15.959 their storage location remove cartridges
00:03:19.069 00:03:19.079 from their packaging and place on top of
00:03:21.920 00:03:21.930 scrubber system the cartridges will slot
00:03:24.590 00:03:24.600 into place with the rubber seals on the
00:03:27.259 00:03:27.269 bottom side replace all cartridges when
00:03:30.650 00:03:30.660 co2 reaches 1 percent or as indicated by
00:03:34.220 00:03:34.230 the life-support settings table located
00:03:36.800 00:03:36.810 on the refuge wall step 9 install Marcus
00:03:41.780 00:03:41.790 orb Co cartridge if carbon monoxide
00:03:44.780 00:03:44.790 concentration reaches 25 ppm remove
00:03:48.770 00:03:48.780 Marcus orb Co cartridge from its storage
00:03:51.800 00:03:51.810 location and packaging remove one co2
00:03:56.059 00:03:56.069 cartridge from top of scrubber and
00:03:58.099 00:03:58.109 replace with Co cartridge use only as
00:04:01.699 00:04:01.709 needed stepped in turn on master control
00:04:06.199 00:04:06.209 valve turn on master control valve
00:04:09.050 00:04:09.060 counterclockwise located on the back
00:04:12.050 00:04:12.060 wall
00:04:13.190 00:04:13.200 step 11 turn on temperature control
00:04:16.550 00:04:16.560 valves turn on all temperature control
00:04:19.520 00:04:19.530 valves TCV one two three and four for
00:04:24.260 00:04:24.270 one minute to start scrubber system step
00:04:29.750 00:04:29.760 12 turn off temperature control valves
00:04:32.810 00:04:32.820 turn off temperature control valves TCV
00:04:36.650 00:04:36.660 two three and four only caution TCV one
00:04:42.290 00:04:42.300 remains on at all times unless internal
00:04:45.440 00:04:45.450 temperature is below 65 degrees
00:04:47.840 00:04:47.850 Fahrenheit or 18 degrees Celsius cycle
00:04:52.070 00:04:52.080 TC v1 when co2 reaches one percent by
00:04:56.030 00:04:56.040 turning on for 30 minutes repeat as
00:04:59.960 00:04:59.970 needed step 13 monitor wet bulb
00:05:04.670 00:05:04.680 temperature turn on TCB two three and
00:05:08.930 00:05:08.940 four individually to increase cooling of
00:05:12.260 00:05:12.270 wet bulb temperature exceeds 84 degrees
00:05:14.870 00:05:14.880 Fahrenheit or 28 degrees Celsius observe
00:05:19.850 00:05:19.860 temperature and relative humidity on
00:05:21.710 00:05:21.720 hygrometer and refer to wet bulb
00:05:23.960 00:05:23.970 temperature chart on refuge wall caution
00:05:27.650 00:05:27.660 using additional TC vs when not needed
00:05:30.890 00:05:30.900 will consume additional cooling
00:05:33.350 00:05:33.360 refrigerant and potentially reduce
00:05:35.779 00:05:35.789 scrubber operating time to less than 96
00:05:39.110 00:05:39.120 hours step 14 install and adjust o2 flow
00:05:44.570 00:05:44.580 meter remove flow meter and gloves from
00:05:48.260 00:05:48.270 sealed case put on nitrile gloves and
00:05:52.520 00:05:52.530 connect flow meter to Quick Connect
00:05:54.620 00:05:54.630 coupling
00:05:56.399 00:05:56.409 adjust flowmeter to 0.5 liters per
00:06:00.209 00:06:00.219 occupant by rotating knob counter
00:06:03.149 00:06:03.159 clockwise see life support settings
00:06:06.479 00:06:06.489 table on refuge wall for flow rates step
00:06:10.169 00:06:10.179 15 gas monitoring retrieve with pump gas
00:06:14.609 00:06:14.619 monitor marker and timer from air lock
00:06:18.119 00:06:18.129 and turn off by pushing the power button
00:06:20.989 00:06:20.999 use for external monitoring only use the
00:06:25.320 00:06:25.330 without pump gas monitor to monitor
00:06:27.629 00:06:27.639 internal o2 Co to Co and ch4 adjust
00:06:34.109 00:06:34.119 oxygen flow meter and replace marcos orb
00:06:36.959 00:06:36.969 co2 cartridges when gases are outside
00:06:40.259 00:06:40.269 acceptable gas concentrations refer to
00:06:43.829 00:06:43.839 the bottom of the life-support settings
00:06:45.749 00:06:45.759 table on the refuge wall for a guide on
00:06:48.419 00:06:48.429 reading alarms and ensuring that
00:06:50.429 00:06:50.439 breathing air quality is maintained gas
00:06:55.019 00:06:55.029 testing guide using the timer and marker
00:06:59.040 00:06:59.050 record gas concentrations and wet bulb
00:07:02.459 00:07:02.469 temperature hourly on the charts located
00:07:05.549 00:07:05.559 at the rear of the photographic
00:07:07.350 00:07:07.360 operating procedures insufficient oxygen
00:07:11.279 00:07:11.289 level in the refuge if oxygen level is
00:07:15.569 00:07:15.579 less than 18.5 percent adjust the oxygen
00:07:19.709 00:07:19.719 flow meter up accordingly high oxygen
00:07:24.149 00:07:24.159 concentration detected in the refuge if
00:07:27.919 00:07:27.929 oxygen concentration exceeds 23% turn
00:07:32.489 00:07:32.499 flow meter off ensure airlock doors open
00:07:36.569 00:07:36.579 an open ball valve to commence airlock
00:07:39.600 00:07:39.610 flushing flush until oxygen
00:07:41.959 00:07:41.969 concentration inside main refuge is less
00:07:45.509 00:07:45.519 than twenty two percent turn flow meter
00:07:48.749 00:07:48.759 on when oxygen concentration is twenty
00:07:51.989 00:07:51.999 percent excess carbon dioxide detected
00:07:56.069 00:07:56.079 in refuge
00:07:57.879 00:07:57.889 if carbon dioxide level exceeds 1%
00:08:01.360 00:08:01.370 remove the Marcus orb co2 cartridges
00:08:04.659 00:08:04.669 from the scrubber and replace with new
00:08:06.969 00:08:06.979 cartridges refer to the life support
00:08:09.999 00:08:10.009 settings table for approximate Marcus
00:08:12.489 00:08:12.499 orb co2 cartridge replacement duration
00:08:15.809 00:08:15.819 step 16 emergency gas bypass system the
00:08:21.279 00:08:21.289 emergency gas bypass system is a safety
00:08:24.040 00:08:24.050 feature designed to extend the duration
00:08:26.019 00:08:26.029 of the refuge the system must only be
00:08:29.019 00:08:29.029 activated after 96 hours of normal
00:08:32.500 00:08:32.510 operation before activating the system
00:08:35.649 00:08:35.659 the high pressure gauge on the scrubber
00:08:37.870 00:08:37.880 must read below 400 psi or the scrubber
00:08:42.699 00:08:42.709 air flow with altie CVS on must be too
00:08:47.050 00:08:47.060 low to maintain a co2 concentration
00:08:50.319 00:08:50.329 below 1% to activate the system ensure
00:08:54.759 00:08:54.769 all T Seavey's are on open the emergency
00:08:58.480 00:08:58.490 gas bypass valve located on the left
00:09:01.840 00:09:01.850 hand side of the scrubber system rotate
00:09:05.290 00:09:05.300 knob counterclockwise until low pressure
00:09:08.319 00:09:08.329 gauge reads between 30 to 50 psi use the
00:09:13.720 00:09:13.730 lowest pressure that allows gas
00:09:15.670 00:09:15.680 concentration to remain at acceptable
00:09:18.130 00:09:18.140 levels for further information refer to
00:09:21.910 00:09:21.920 general overview and operating
00:09:23.889 00:09:23.899 procedures the most important thing you
00:09:26.949 00:09:26.959 can do now is to make sure your refuge
00:09:29.829 00:09:29.839 is maintained and good operational order
00:09:32.620 00:09:32.630 so in the unfortunate event you need to
00:09:35.380 00:09:35.390 use the refuge you can feel safe knowing
00:09:38.110 00:09:38.120 that it is ready for use this can be
00:09:40.900 00:09:40.910 accomplished through weekly checks and
00:09:42.670 00:09:42.680 regular servicing which can be carried
00:09:45.519 00:09:45.529 out by my narc systems for further
00:09:48.250 00:09:48.260 details or if you have any queries
00:09:50.680 00:09:50.690 regarding the operation of a coal safe
00:09:53.110 00:09:53.120 refuge please contact my narc systems or
00:09:56.500 00:09:56.510 visit the website at WWE com