/ News & Press / Video / OXYGEN NOT INCLUDED - EASIEST FULLY AUTOMATIC PETROLEUM BOILER
OXYGEN NOT INCLUDED - EASIEST FULLY AUTOMATIC PETROLEUM BOILER
WEBVTT Kind: captions Language: en
00:00:06.680 hello welcome back to a very quick video 00:00:10.85000:00:10.860 I'm actually really excited about this 00:00:12.74000:00:12.750 one I have made a fully autonomous troll 00:00:18.08000:00:18.090 iam boiler so boiling crude oil into 00:00:20.68900:00:20.699 petroleum so for those who that might be 00:00:22.70000:00:22.710 unaware or those either didn't play this 00:00:24.50000:00:24.510 game many moons ago we used to be able 00:00:26.66000:00:26.670 to boil crude oil straight into 00:00:29.02900:00:29.039 petroleum and that was all well and good 00:00:31.04000:00:31.050 we could get petroleum and then if we 00:00:32.87000:00:32.880 wanted to we could boil petroleum into 00:00:34.63900:00:34.649 natural gas and it was just a three-step 00:00:37.94000:00:37.950 process they've changed it a little 00:00:39.47000:00:39.480 while ago where now when we boil 00:00:40.91000:00:40.920 petroleum we end up getting sour gas and 00:00:43.76000:00:43.770 sour gas there needs to be cooled and 00:00:46.16000:00:46.170 condensed and then warmed and then you 00:00:48.47000:00:48.480 get natural gas well this is sort of 00:00:50.69000:00:50.700 just a petroleum boiler today what I'm 00:00:52.22000:00:52.230 what I'm trying to do here is heat up my 00:00:54.47000:00:54.480 crude oil to the point where it boils 00:00:57.08000:00:57.090 into petroleum and then gets dumped away 00:00:58.81900:00:58.829 and pump to wherever you want and I've 00:01:00.74000:01:00.750 just got a big massive material up here 00:01:03.26000:01:03.270 which I'll explain in a minute so what 00:01:05.50900:01:05.519 we've basically got in this room we have 00:01:07.10000:01:07.110 a crude oil feed down here and what 00:01:11.21000:01:11.220 we're going to do we're going to top up 00:01:12.28900:01:12.299 the build as and when it needs it via 00:01:13.82000:01:13.830 this liquid shutoff and this is just on 00:01:15.49900:01:15.509 a little bit of automation literally a 00:01:17.66000:01:17.670 hydra sensor set to below 150 kilos 00:01:20.89000:01:20.900 connected to a liquid shutoff now what 00:01:23.60000:01:23.610 we've got in the room is a couple of 00:01:25.07000:01:25.080 aqua tuners and these aquatune is our 00:01:27.26000:01:27.270 setup inline so the feed will come down 00:01:30.31900:01:30.329 here we've got some super coolant in the 00:01:32.03000:01:32.040 pipe that's going through a little 00:01:33.08000:01:33.090 radiator this is just signifying maybe 00:01:36.08000:01:36.090 your cooling your base maybe your 00:01:37.67000:01:37.680 cooling down something you know and in 00:01:39.83000:01:39.840 the space biome whatever this could be 00:01:42.17000:01:42.180 cool in your entire base technically 00:01:43.70000:01:43.710 this loop alright cooling some water 00:01:45.56000:01:45.570 some plants anything but what it 00:01:47.51000:01:47.520 basically does the super coolant coming 00:01:48.64900:01:48.659 down in this direction it hits this aqua 00:01:50.66000:01:50.670 tuna and unless this pipe sensor tells 00:01:52.78900:01:52.799 it otherwise it's going to pass through 00:01:55.06900:01:55.079 this aqua tuna into the next one and on 00:01:57.49900:01:57.509 its way and then it just goes through 00:01:58.58000:01:58.590 the loop if this pipe sensor here the 00:02:01.52000:02:01.530 text that the the temperature the super 00:02:03.80000:02:03.810 coolant is going to cold and I don't 00:02:05.60000:02:05.610 want to freeze anything you know I don't 00:02:07.01000:02:07.020 wanna go any lower it will bypass and it 00:02:09.19900:02:09.209 bypasses the same way we know when we do 00:02:10.72900:02:10.739 it straight piece of pipe into a bridge 00:02:12.94900:02:12.959 and 00:02:13.37000:02:13.380 bridges into the output the feed and 00:02:15.05000:02:15.060 this just allows the liquid to circulate 00:02:16.79000:02:16.800 all right mmm beauty this is that it 00:02:20.33000:02:20.340 keeps the flow going even when the Aqua 00:02:22.19000:02:22.200 tuners are toggled off and the Aqua 00:02:23.72000:02:23.730 tuned automation is pretty simple I'll 00:02:25.82000:02:25.830 just explain this now we've got one of 00:02:28.01000:02:28.020 the opportunist the first aqua tuner in 00:02:29.84000:02:29.850 line needs to be connected the other one 00:02:31.19000:02:31.200 doesn't need to because that's the slave 00:02:32.57000:02:32.580 to this one sort of thing this this pipe 00:02:35.90000:02:35.910 sensor here the thermal sensor goes to a 00:02:37.97000:02:37.980 NAND gate and this angei also has 00:02:40.19000:02:40.200 another connection over here which is a 00:02:41.78000:02:41.790 Hydra sensor now in this little little 00:02:44.09000:02:44.100 chamber we've got some of the new super 00:02:46.01000:02:46.020 cooling and one of the interest in 00:02:47.60000:02:47.610 properties are super cool now noticed is 00:02:49.55000:02:49.560 that it evaporates at four hundred and 00:02:51.56000:02:51.570 thirty six point nine degrees so the 00:02:53.99000:02:54.000 problem used to have with these boilers 00:02:55.49000:02:55.500 is that we'd cook too far in the 00:02:57.05000:02:57.060 petroleum and get too hot and then it 00:02:58.73000:02:58.740 balls the whole thing up well with this 00:03:01.19000:03:01.200 evaporation of four hundred and thirty 00:03:02.60000:03:02.610 six point nine degrees I've used the 00:03:04.91000:03:04.920 Hydra sensor in here and a little bit of 00:03:06.59000:03:06.600 supercooled and only a few grams in here 00:03:08.15000:03:08.160 three thousand grams in each tile and 00:03:10.52000:03:10.530 what that basically means is when this 00:03:11.93000:03:11.940 oil or the petroleum reaches the right 00:03:14.75000:03:14.760 temperature of about four hundred and 00:03:17.30000:03:17.310 thirty-eight degrees it will boil and 00:03:19.58000:03:19.590 the Hydra sensor that's currently 00:03:20.90000:03:20.910 looking for a liquid reading if you like 00:03:23.30000:03:23.310 a pressure in front of it in a liquid 00:03:25.31000:03:25.320 form of two kilos this will toggle off 00:03:29.24000:03:29.250 and what that will then do is flip this 00:03:32.09000:03:32.100 signal this sends a signal to my door to 00:03:34.91000:03:34.920 open up a little mechanised a lot down 00:03:36.56000:03:36.570 here and it also will toggle off the 00:03:39.89000:03:39.900 Aqua tuner as well because if this is 00:03:42.08000:03:42.090 boiled I don't need any more Heat's off 00:03:43.55000:03:43.560 macro tuners we're using the Aqua tuners 00:03:45.35000:03:45.360 to boil our patrolling all right and 00:03:47.54000:03:47.550 then as I say the the door will open 00:03:49.69900:03:49.709 petroleum gets dumped in here and away 00:03:51.44000:03:51.450 we go so if I unpause this we're 00:03:54.41000:03:54.420 probably pretty close to boiling so yeah 00:03:58.25000:03:58.260 there we go 00:03:58.69900:03:58.709 so what's just happened this tile of 00:04:01.35000:04:01.360 [Music] 00:04:02.71000:04:02.720 super coolant has now boiled so it's now 00:04:04.89900:04:04.909 in gaseous form okay and this tile is 00:04:08.44000:04:08.450 going to boil in just a second and you 00:04:09.78900:04:09.799 can see what happens on the automation 00:04:17.97900:04:17.989 when it boils there we go so what's our 00:04:21.18900:04:21.199 that's now gonna do it's toggled this 00:04:22.54000:04:22.550 signal off our aqua tuners are now off 00:04:24.58000:04:24.590 and in a short second this'll open and 00:04:27.15900:04:27.169 our patrolling will dump into here 00:04:29.37000:04:29.380 OOP at which point this this Hydra 00:04:32.95000:04:32.960 sensor over here is going to notice that 00:04:34.15000:04:34.160 the flow is dropped the amount of 00:04:35.49900:04:35.509 pressure in the room is dropped and it's 00:04:37.05900:04:37.069 going to start pumping in more crude oil 00:04:38.55900:04:38.569 and that crude oils then going to boil 00:04:41.01000:04:41.020 so what we're basically doing we're 00:04:43.87000:04:43.880 creating petroleum at 400 not degrees 00:04:47.99900:04:48.009 440 degrees and this will continue now 00:04:51.52000:04:51.530 just to pump through like this the room 00:04:53.02000:04:53.030 is hot enough to keep boiling this oil 00:04:54.73000:04:54.740 as soon as it hits this plate now 00:04:56.77000:04:56.780 eventually as it's just happened now 00:04:58.71000:04:58.720 super coolant is going to liquefy again 00:05:01.42000:05:01.430 it's going to condense sorry it's going 00:05:03.01000:05:03.020 to turn into its liquid form sit on top 00:05:04.96000:05:04.970 of the Hydra sensor which will toggle 00:05:06.79000:05:06.800 the automation back on and it's just 00:05:08.56000:05:08.570 going to keep doing this now it's going 00:05:09.67000:05:09.680 to keep cycling more petroleum will be 00:05:12.87900:05:12.889 cooked in the room and then again once 00:05:15.46000:05:15.470 this boils again this door will open and 00:05:17.26000:05:17.270 pump it away I'm really happy with this 00:05:19.80900:05:19.819 it's a really small little compact build 00:05:21.70000:05:21.710 I am really pleased with it 00:05:23.46900:05:23.479 there's been lots of people doing other 00:05:25.06000:05:25.070 boilers patrolling boilers have been a 00:05:26.95000:05:26.960 hot topic petroleum boilers have been a 00:05:31.33000:05:31.340 common place on the forums for a long 00:05:33.73000:05:33.740 time a lot of people do magma boilers 00:05:35.83000:05:35.840 now that we've got these new materials 00:05:37.60000:05:37.610 we can play with some of the techniques 00:05:39.37000:05:39.380 and this is this is the first time I've 00:05:40.95900:05:40.969 seen this I'm hoping it's interesting to 00:05:42.96900:05:42.979 you all as a safe automation incredibly 00:05:45.73000:05:45.740 simple one Hydra Center to our oil feed 00:05:49.30000:05:49.310 we've got a Hydra Center in our super 00:05:51.21900:05:51.229 coolant and we've got a pipe sensor on 00:05:53.23000:05:53.240 the actual pipe to the aquatune I don't 00:05:54.99900:05:55.009 think it gets much easier than that as I 00:05:57.64000:05:57.650 say I've powered this with have you what 00:05:58.89900:05:58.909 wire so there have you what wire comes 00:06:00.70000:06:00.710 in and powers our opportunist and then 00:06:02.35000:06:02.360 it's literally 250 watts for the rest of 00:06:05.02000:06:05.030 the power in the room and yeah it seems 00:06:08.02000:06:08.030 to be working absolutely beautifully so 00:06:10.08900:06:10.099 I have no idea of through ports I don't 00:06:11.68000:06:11.690 know how much this is generate input as 00:06:13.42000:06:13.430 you can see we're getting you know quite 00:06:15.33900:06:15.349 a bit petroleum coming from this so I 00:06:17.58900:06:17.599 hope that helps I've not come up with a 00:06:20.35000:06:20.360 core 00:06:21.04000:06:21.050 corny name for it 00:06:22.96000:06:22.970 I will just call it the petroleum boiler 00:06:25.24000:06:25.250 of destiny yeah any questions let me 00:06:29.23000:06:29.240 know in the comments or come by me on 00:06:30.76000:06:30.770 Twitch but yeah 00:06:32.05000:06:32.060 much love take it easy bye bye
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12