00:00:11.360 plate and frame heat exchangers consist 00:00:14.78000:00:14.790 of a series of plates held together with 00:00:16.64000:00:16.650 a frame each plate is the boundary where 00:00:19.91000:00:19.920 heat transfer occurs between hot and 00:00:22.22000:00:22.230 cold fluids the spaces between plates 00:00:25.49000:00:25.500 are called channels and there are two 00:00:28.46000:00:28.470 utility fluid channels for every product 00:00:31.13000:00:31.140 channel this is the minimum 00:00:33.26000:00:33.270 configuration for a pass 00:00:35.27000:00:35.280 although a typical pass has many more 00:00:37.63900:00:37.649 channels a gasket is used between 00:00:40.34000:00:40.350 each channel to hold utility or product 00:00:43.06900:00:43.079 flow in that channel in order to keep 00:00:45.86000:00:45.870 fluid spread out across the plates the 00:00:48.31900:00:48.329 plate surface is corrugated into a 00:00:50.66000:00:50.670 v-shaped pattern the v-shaped stamp is 00:00:53.84000:00:53.850 alternated between plates facing each 00:00:56.15000:00:56.160 other to enhance mixing in the channel 00:00:58.88000:00:58.890 flow special plates called 00:01:01.34000:01:01.350 end or transition plates with unique 00:01:03.88900:01:03.899 gaskets and blocked ports direct over 00:01:06.64900:01:06.659 all product and utility flow in a pass 00:01:09.42900:01:09.439 these plates are used at the end of a 00:01:12.26000:01:12.270 pass or next to the frame looking at 00:01:15.05000:01:15.060 flow in this one pass configuration 00:01:17.53000:01:17.540 utility flow moves through an inlet and 00:01:20.53900:01:20.549 through every other channel before it 00:01:23.09000:01:23.100 exits the heat exchanger product flow 00:01:25.82000:01:25.830 does the same except in the opposite 00:01:28.42900:01:28.439 direction the hot and cold fluids 00:01:30.95000:01:30.960 typically run in counter current 00:01:32.78000:01:32.790 directions to maximize heat transfer 00:01:35.74000:01:35.750 although the heat exchangers shown is in 00:01:38.74900:01:38.759 a one pass setup plate and frame heat 00:01:41.53900:01:41.549 exchangers can also be configured in two 00:01:44.38900:01:44.399 or multipass arrangements plate heat 00:01:47.87000:01:47.880 exchangers are known for their low cost 00:01:50.14900:01:50.159 small footprint and ease of 00:01:53.23000:01:53.240 reconfiguration 00:02:00.89000:02:00.900 you
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12