Second Sun Tank Heater

WEBVTT
Kind: captions
Language: en

00:00:21.620
all gasp STI developed its first
00:00:24.520 00:00:24.530 vaporizer in 1932 today after more than
00:00:27.940 00:00:27.950 80 years of innovation we continue that
00:00:30.520 00:00:30.530 tradition as we introduce the second son
00:00:32.830 00:00:32.840 tank heater second son safely and
00:00:35.140 00:00:35.150 efficiently enhances vaporization that
00:00:37.540 00:00:37.550 occurs naturally in any propane LPG or
00:00:40.570 00:00:40.580 anhydrous ammonia tank second son is
00:00:43.450 00:00:43.460 cleverly engineered and attractively
00:00:45.430 00:00:45.440 packaged it uses a flameless catalytic
00:00:48.370 00:00:48.380 heater to augment the energy being
00:00:50.110 00:00:50.120 provided by the Sun when ambient
00:00:52.510 00:00:52.520 environmental energy is lacking second
00:00:54.700 00:00:54.710 Sun is an ideal solution second Suns
00:00:57.549 00:00:57.559 typical application is to maintain
00:00:59.530 00:00:59.540 pressure in a storage tank as vapor is
00:01:01.780 00:01:01.790 consumed second Sun also comes equipped
00:01:04.329 00:01:04.339 with a high pressure safety switch to
00:01:06.430 00:01:06.440 prevent over pressurization of the tank
00:01:08.550 00:01:08.560 during normal operation tank pressure
00:01:10.990 00:01:11.000 drops as vapor is used when tank
00:01:13.690 00:01:13.700 pressure falls below approximately 50
00:01:15.940 00:01:15.950 psig or three point four or five bar
00:01:18.460 00:01:18.470 gage second Sun is activated and turns
00:01:21.160 00:01:21.170 on second Sun returns to stand by when
00:01:24.370 00:01:24.380 tank pressure is restored to 60 psi G or
00:01:27.700 00:01:27.710 four point one four bar gage let's talk
00:01:31.000 00:01:31.010 a little about how second Sun works
00:01:32.880 00:01:32.890 first and perhaps most important
00:01:35.380 00:01:35.390 catalytic heating involves no flame
00:01:37.950 00:01:37.960 instead catalytic heating occurs as
00:01:40.600 00:01:40.610 propane or LPG vapor comes in contact
00:01:43.180 00:01:43.190 with an electrically heated catalyst
00:01:45.280 00:01:45.290 surface
00:01:45.730 00:01:45.740 this causes complex molecules to
00:01:48.580 00:01:48.590 rearrange as simpler molecular
00:01:50.560 00:01:50.570 structures while at the same time giving
00:01:52.900 00:01:52.910 off heat as the primary by-product
00:01:54.910 00:01:54.920 second Sun emits this heat against the
00:01:57.400 00:01:57.410 wetted surface of the tank as infrared
00:01:59.560 00:01:59.570 waves similar to a radiant heater this
00:02:02.290 00:02:02.300 warm low intensity heat mimics the
00:02:04.600 00:02:04.610 energy from the Sun induces vaporization
00:02:07.540 00:02:07.550 and maintains tank equilibrium pressure
00:02:09.940 00:02:09.950 while vapor is consumed second Sun
00:02:12.520 00:02:12.530 requires no AC electricity startup
00:02:15.640 00:02:15.650 energy for the catalytic reaction
00:02:17.160 00:02:17.170 12-volt DC is provided using jumper
00:02:20.500 00:02:20.510 cables from a vehicle battery
00:02:22.540 00:02:22.550 after startup sufficient voltage to
00:02:24.670 00:02:24.680 operate the gas security valve is self
00:02:26.830 00:02:26.840 generated by a physical phenomenon known
00:02:29.350 00:02:29.360 as thermoelectric effect this power
00:02:32.020 00:02:32.030 generating technique converts
00:02:33.700 00:02:33.710 temperature differentials directly to
00:02:35.710 00:02:35.720 electrical voltage the main heater
00:02:37.750 00:02:37.760 provides operational heat it could not
00:02:40.210 00:02:40.220 be simpler to temperature switches
00:02:42.400 00:02:42.410 integral to the second Sun monitor the
00:02:44.680 00:02:44.690 surface temperature of the storage tank
00:02:46.210 00:02:46.220 at two different elevations the
00:02:48.610 00:02:48.620 temperature switch in the higher
00:02:49.960 00:02:49.970 elevation position terminates gas flow
00:02:52.330 00:02:52.340 to the main burner if tripped if trip
00:02:54.850 00:02:54.860 the heater returns to standby or pilot
00:02:57.250 00:02:57.260 mode the lower position switch when
00:02:59.860 00:02:59.870 tripped causes the second Sun to
00:03:01.870 00:03:01.880 completely shut off manual restart is
00:03:04.750 00:03:04.760 required also if the pilot heater
00:03:07.300 00:03:07.310 temperature drops below the temperature
00:03:09.190 00:03:09.200 necessary to catalyze the fuel the
00:03:11.560 00:03:11.570 second Sun completely shuts off again
00:03:14.170 00:03:14.180 manual restart is required second Sun is
00:03:17.350 00:03:17.360 an innovative flameless design it's
00:03:19.930 00:03:19.940 ideal for hotels resorts restaurants
00:03:22.330 00:03:22.340 small factories and other temporary or
00:03:25.510 00:03:25.520 portable applications second Sun another
00:03:28.960 00:03:28.970 world class vaporization solution from
00:03:31.690 00:03:31.700 all gas SDI
00:03:39.550 00:03:39.560 you
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12

Phone: +7 343 216 77 75

E-mail: info@lotus1.ru

Sales phone

Russia: +7 343 216 77 75

WhatsApp: +79122710308