00:00:21.620 all gasp STI developed its first 00:00:24.52000:00:24.530 vaporizer in 1932 today after more than 00:00:27.94000:00:27.950 80 years of innovation we continue that 00:00:30.52000:00:30.530 tradition as we introduce the second son 00:00:32.83000:00:32.840 tank heater second son safely and 00:00:35.14000:00:35.150 efficiently enhances vaporization that 00:00:37.54000:00:37.550 occurs naturally in any propane LPG or 00:00:40.57000:00:40.580 anhydrous ammonia tank second son is 00:00:43.45000:00:43.460 cleverly engineered and attractively 00:00:45.43000:00:45.440 packaged it uses a flameless catalytic 00:00:48.37000:00:48.380 heater to augment the energy being 00:00:50.11000:00:50.120 provided by the Sun when ambient 00:00:52.51000:00:52.520 environmental energy is lacking second 00:00:54.70000:00:54.710 Sun is an ideal solution second Suns 00:00:57.54900:00:57.559 typical application is to maintain 00:00:59.53000:00:59.540 pressure in a storage tank as vapor is 00:01:01.78000:01:01.790 consumed second Sun also comes equipped 00:01:04.32900:01:04.339 with a high pressure safety switch to 00:01:06.43000:01:06.440 prevent over pressurization of the tank 00:01:08.55000:01:08.560 during normal operation tank pressure 00:01:10.99000:01:11.000 drops as vapor is used when tank 00:01:13.69000:01:13.700 pressure falls below approximately 50 00:01:15.94000:01:15.950 psig or three point four or five bar 00:01:18.46000:01:18.470 gage second Sun is activated and turns 00:01:21.16000:01:21.170 on second Sun returns to stand by when 00:01:24.37000:01:24.380 tank pressure is restored to 60 psi G or 00:01:27.70000:01:27.710 four point one four bar gage let's talk 00:01:31.00000:01:31.010 a little about how second Sun works 00:01:32.88000:01:32.890 first and perhaps most important 00:01:35.38000:01:35.390 catalytic heating involves no flame 00:01:37.95000:01:37.960 instead catalytic heating occurs as 00:01:40.60000:01:40.610 propane or LPG vapor comes in contact 00:01:43.18000:01:43.190 with an electrically heated catalyst 00:01:45.28000:01:45.290 surface 00:01:45.73000:01:45.740 this causes complex molecules to 00:01:48.58000:01:48.590 rearrange as simpler molecular 00:01:50.56000:01:50.570 structures while at the same time giving 00:01:52.90000:01:52.910 off heat as the primary by-product 00:01:54.91000:01:54.920 second Sun emits this heat against the 00:01:57.40000:01:57.410 wetted surface of the tank as infrared 00:01:59.56000:01:59.570 waves similar to a radiant heater this 00:02:02.29000:02:02.300 warm low intensity heat mimics the 00:02:04.60000:02:04.610 energy from the Sun induces vaporization 00:02:07.54000:02:07.550 and maintains tank equilibrium pressure 00:02:09.94000:02:09.950 while vapor is consumed second Sun 00:02:12.52000:02:12.530 requires no AC electricity startup 00:02:15.64000:02:15.650 energy for the catalytic reaction 00:02:17.16000:02:17.170 12-volt DC is provided using jumper 00:02:20.50000:02:20.510 cables from a vehicle battery 00:02:22.54000:02:22.550 after startup sufficient voltage to 00:02:24.67000:02:24.680 operate the gas security valve is self 00:02:26.83000:02:26.840 generated by a physical phenomenon known 00:02:29.35000:02:29.360 as thermoelectric effect this power 00:02:32.02000:02:32.030 generating technique converts 00:02:33.70000:02:33.710 temperature differentials directly to 00:02:35.71000:02:35.720 electrical voltage the main heater 00:02:37.75000:02:37.760 provides operational heat it could not 00:02:40.21000:02:40.220 be simpler to temperature switches 00:02:42.40000:02:42.410 integral to the second Sun monitor the 00:02:44.68000:02:44.690 surface temperature of the storage tank 00:02:46.21000:02:46.220 at two different elevations the 00:02:48.61000:02:48.620 temperature switch in the higher 00:02:49.96000:02:49.970 elevation position terminates gas flow 00:02:52.33000:02:52.340 to the main burner if tripped if trip 00:02:54.85000:02:54.860 the heater returns to standby or pilot 00:02:57.25000:02:57.260 mode the lower position switch when 00:02:59.86000:02:59.870 tripped causes the second Sun to 00:03:01.87000:03:01.880 completely shut off manual restart is 00:03:04.75000:03:04.760 required also if the pilot heater 00:03:07.30000:03:07.310 temperature drops below the temperature 00:03:09.19000:03:09.200 necessary to catalyze the fuel the 00:03:11.56000:03:11.570 second Sun completely shuts off again 00:03:14.17000:03:14.180 manual restart is required second Sun is 00:03:17.35000:03:17.360 an innovative flameless design it's 00:03:19.93000:03:19.940 ideal for hotels resorts restaurants 00:03:22.33000:03:22.340 small factories and other temporary or 00:03:25.51000:03:25.520 portable applications second Sun another 00:03:28.96000:03:28.970 world class vaporization solution from 00:03:31.69000:03:31.700 all gas SDI 00:03:39.55000:03:39.560 you
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12