/ News & Press / Video / Simple Furnace Heat Exchanger Test _ HVAC Learning Solutions
Simple Furnace Heat Exchanger Test _ HVAC Learning Solutions
WEBVTT Kind: captions Language: en
00:00:00.000 hi this is Jose teleport here with HDAC 00:00:02.75000:00:02.760 learning solutions want to talk to you 00:00:04.97000:00:04.980 today about testing a furnace heat 00:00:06.49900:00:06.509 exchanger that you think might be 00:00:08.24000:00:08.250 cracked or damaged now this can be a 00:00:11.00000:00:11.010 tricky situation for some people to 00:00:12.77000:00:12.780 inspect some really don't know the 00:00:14.78000:00:14.790 simplest and easiest ways to test them 00:00:16.60900:00:16.619 while it's true we can disassemble the 00:00:18.71000:00:18.720 heat exchanger take the manifold the 00:00:21.14000:00:21.150 burners out and do a visual inspection 00:00:22.88000:00:22.890 and though we can come in with expection 00:00:25.46000:00:25.470 cameras or multiple mirrors and 00:00:29.24000:00:29.250 flashlights to inspect them there's a 00:00:31.13000:00:31.140 very simple test that you can perform 00:00:32.74900:00:32.759 first typically without having to 00:00:35.20900:00:35.219 disassemble anything and that's the 00:00:37.28000:00:37.290 static pressure test what that means is 00:00:40.36900:00:40.379 that we turn the furnaces fan on but 00:00:42.65000:00:42.660 leave the heating system off that will 00:00:44.93000:00:44.940 engage the blower motor right below the 00:00:46.72900:00:46.739 burners and that will start pushing 00:00:48.50000:00:48.510 positively pressurized air across the 00:00:50.56900:00:50.579 heat exchanger if any of the heat 00:00:53.02900:00:53.039 exchanger cells are breached or cracked 00:00:55.93900:00:55.949 the air from the blower will enter one 00:00:58.58000:00:58.590 of these cells and we can simply do a 00:01:01.31000:01:01.320 standing match test to see if the flame 00:01:04.25000:01:04.260 is blown around extinguished or 00:01:06.62000:01:06.630 distorted in any way when we test the 00:01:09.41000:01:09.420 heat exchanger that doesn't have a crack 00:01:11.14900:01:11.159 there should be no visual sign of the 00:01:13.34000:01:13.350 flame moving pretty much at all so let's 00:01:16.88000:01:16.890 go ahead and inspect this furnace 00:01:18.26000:01:18.270 starting from this end and we'll work 00:01:20.87000:01:20.880 our way across see if we can visually 00:01:23.24000:01:23.250 see what happens when a heat exchanger 00:01:25.52000:01:25.530 is cracked using the static pressure 00:01:27.10900:01:27.119 test 00:01:28.71000:01:28.720 so we'll light a match on the 00:01:30.18000:01:30.190 telescoping wand we'll go to the first 00:01:33.72000:01:33.730 heat exchanger cell you notice when I 00:01:36.51000:01:36.520 put the flame in the match stays about 00:01:38.58000:01:38.590 the same it's consistent there's no real 00:01:40.41000:01:40.420 moving I go to the second one and again 00:01:44.24000:01:44.250 there's no distortion of the flame now 00:01:47.91000:01:47.920 let's go to the next one we can see as 00:01:50.55000:01:50.560 we get close the flames already dancing 00:01:52.38000:01:52.390 by the time we get inside the cell it's 00:01:54.84000:01:54.850 completely extinguished I think we just 00:01:58.02000:01:58.030 found our damage to eat exchange 00:01:59.64000:01:59.650 yourself now we can go ahead and utilize 00:02:02.58000:02:02.590 one of our other test methods like an 00:02:04.92000:02:04.930 inspection camera inspection mirror or 00:02:07.71000:02:07.720 disassembling the furnace and looking at 00:02:09.48000:02:09.490 the heat exchanger itself to verify it 00:02:11.76000:02:11.770 but this quick and easy test will allow 00:02:14.91000:02:14.920 you to see if you have a damaged or 00:02:16.89000:02:16.900 breach eat exchanger in a very short 00:02:19.08000:02:19.090 period of time thank you
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12