/ News & Press / Video / Steam boiler operation - the inside story Part 7 - very high demand
Steam boiler operation - the inside story Part 7 - very high demand
WEBVTT Kind: captions Language: en
00:00:04.940 if the steam demand is increased beyond 00:00:07.38900:00:07.399 the limit of the boilers maximum steam 00:00:09.12900:00:09.139 generation rate even for a very short 00:00:11.17000:00:11.180 time problems can occur with both 00:00:13.08900:00:13.099 carryover and low boiler water level in 00:00:15.49000:00:15.500 fact it's not uncommon for a boiler to 00:00:17.80000:00:17.810 shut down when overloaded due to the low 00:00:20.32000:00:20.330 level alarm operating to explain this 00:00:22.92900:00:22.939 watch what happens when the steam demand 00:00:25.08900:00:25.099 is gradually increased to just 15% above 00:00:28.00000:00:28.010 the boilers maximum rated output as 00:00:30.12000:00:30.130 expected the drop in pressure is causing 00:00:33.49000:00:33.500 the bubble surface to rise and the 00:00:35.47000:00:35.480 conditions are becoming more turbulent 00:00:37.11900:00:37.129 due to the formation of flash steam 00:00:39.24000:00:39.250 water is soon drawn into the steam take 00:00:42.01000:00:42.020 off but this time without the demand 00:00:43.86900:00:43.879 moderated the turbulent bubble level 00:00:45.97000:00:45.980 continues to rise swapping the camera 00:00:48.27900:00:48.289 pod leading to near continuous carryover 00:00:51.36000:00:51.370 none of this is apparent in the gauge 00:00:53.59000:00:53.600 glass or the protection tube because 00:00:55.60000:00:55.610 they are measuring virtually bubble free 00:00:57.16000:00:57.170 water and the water at the top of the 00:00:59.17000:00:59.180 boiler consists mainly of steam bubbles 00:01:01.42000:01:01.430 the measured levels begin to fall as 00:01:03.72900:01:03.739 water continuously flashes into steam in 00:01:06.01000:01:06.020 the boilers attempt to satisfy the 00:01:07.93000:01:07.940 excessive demand eventually the first 00:01:10.66000:01:10.670 low level alarm is triggered this shuts 00:01:13.27000:01:13.280 down the burner and the bubble charge 00:01:15.13000:01:15.140 water drops very rapidly it soon becomes 00:01:18.13000:01:18.140 apparent how little water is left in the 00:01:19.99000:01:20.000 boiler so little in fact that the stay 00:01:22.63000:01:22.640 bars become exposed this demonstrates 00:01:26.65000:01:26.660 just how important it is to keep a 00:01:28.66000:01:28.670 boiler operating within its design 00:01:29.94900:01:29.959 parameters and the need for reliable 00:01:32.32000:01:32.330 accurate level probes
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12