/ News & Press / Video / Troubleshooting if a Thermostat is BAD - Explained!
Troubleshooting if a Thermostat is BAD - Explained!
WEBVTT Kind: captions Language: en
00:00:08.810 all right this video is about how to 00:00:11.63000:00:11.640 tell if your thermostat is bad first 00:00:14.27000:00:14.280 thing you're going to want to do is 00:00:15.35000:00:15.360 you're going to want to pull apart right 00:00:17.21000:00:17.220 here on your thermostat open up the face 00:00:20.17900:00:20.189 all right so I'm assuming that this LCD 00:00:25.10000:00:25.110 display will be lit up but we're not 00:00:27.35000:00:27.360 able to turn the fan on able to turn the 00:00:29.74900:00:29.759 heat on I'm able to turn the cooling off 00:00:31.90900:00:31.919 so you have red as your 24 to 28 volt 00:00:36.53000:00:36.540 power wire coming in and then it goes 00:00:39.20000:00:39.210 back out either the white yellow or a 00:00:42.61900:00:42.629 green wire depending on what your 00:00:44.27000:00:44.280 telling you to do the thermostat when 00:00:46.45900:00:46.469 telling me fan to turn on the 24 volts 00:00:49.04000:00:49.050 will be coming in the red and and coming 00:00:51.77000:00:51.780 back out the G if it was coming in as 00:00:55.54900:00:55.559 red and going back out as the Y that 00:00:57.70900:00:57.719 will be for a cooling 24 volts coming in 00:01:00.29000:01:00.300 for red and if we turn the heat on it 00:01:02.54000:01:02.550 will come back out the white wire and go 00:01:04.52000:01:04.530 to the furnace control board in order to 00:01:07.13000:01:07.140 tell it what the disk 00:01:08.14900:01:08.159 okay so these are your signal wires so 00:01:10.52000:01:10.530 what we really need to do here is to 00:01:12.62000:01:12.630 determine if if the fan is going to turn 00:01:14.72000:01:14.730 on we could take the display and the 00:01:18.38000:01:18.390 control board out of play a couple of 00:01:20.99000:01:21.000 different ways you could take a 00:01:22.28000:01:22.290 thermostat wire like the strip both ends 00:01:24.86000:01:24.870 and you could use as a jumper all right 00:01:27.14000:01:27.150 so you can pull this faceplate off this 00:01:30.89000:01:30.900 24 volt faceplate while the furnace is 00:01:33.68000:01:33.690 on or the air handler is on all right 00:01:35.78000:01:35.790 it's 24 volts and all Assizes signal 00:01:38.18000:01:38.190 wires the only way that you could short 00:01:39.98000:01:39.990 out the thermostat wires will be by 00:01:42.07000:01:42.080 connecting the red and the blue wire 00:01:45.11000:01:45.120 together that would short out the 00:01:46.85000:01:46.860 transformer and the furnace Warsh or 00:01:48.74000:01:48.750 short out the fuse protecting the 00:01:50.51000:01:50.520 transformer in the furnace all right so 00:01:52.13000:01:52.140 you leave them alone and if you don't 00:01:54.74000:01:54.750 even have a common because you have 00:01:58.22000:01:58.230 batteries in your thermostat you know 00:02:00.47000:02:00.480 then then there's nothing to short it 00:02:01.97000:02:01.980 out against right there unless you hit a 00:02:03.65000:02:03.660 common somewheres else 00:02:05.44000:02:05.450 all right we're ground so you have 24 00:02:10.10000:02:10.110 volts in the arm okay you're going to 00:02:11.78000:02:11.790 connect that over to the G if when you 00:02:15.35000:02:15.360 do this and you put you know pressure on 00:02:17.93000:02:17.940 it you want to keep make sure your 00:02:20.03000:02:20.040 fingers are safe and not touching 00:02:21.55900:02:21.569 the electrode there but if that turns 00:02:25.81900:02:25.829 the fan on then you know that the this 00:02:30.64900:02:30.659 faceplate is bad okay and that the 00:02:32.95900:02:32.969 terminal terminal board back here is 00:02:35.30000:02:35.310 still good all right but if you want to 00:02:38.20900:02:38.219 take this out of play we could we go 00:02:40.94000:02:40.950 about that as well if you didn't have a 00:02:43.22000:02:43.230 jumper like this you could even take 00:02:45.97900:02:45.989 some pair of needlenose okay you could 00:02:47.89900:02:47.909 go from here to here all right and jump 00:02:52.94000:02:52.950 it out that one you could jump it out 00:02:55.36900:02:55.379 with set of jumper wires you know you 00:02:59.27000:02:59.280 could you could push this in here and 00:03:00.92000:03:00.930 this in here just make sure that they're 00:03:02.14900:03:02.159 smaller than the opening okay and that 00:03:04.49000:03:04.500 would jump it out as well 00:03:05.53900:03:05.549 all right in this case since we're going 00:03:07.97000:03:07.980 to pull the wires out we're going to 00:03:09.70900:03:09.719 actually take this out of flight I would 00:03:11.14900:03:11.159 suggest that go ahead and turn your 00:03:12.45900:03:12.469 furnace or air handling off right before 00:03:15.28900:03:15.299 you go touching any of these wires and 00:03:17.30000:03:17.310 pulling them out turn the furnace off 00:03:19.61000:03:19.620 confirm that it's off then you're going 00:03:22.09900:03:22.109 to go ahead and turn your screw 00:03:26.30000:03:26.310 counterclockwise and pull your red wire 00:03:28.15900:03:28.169 out I always like to start with the 00:03:31.36900:03:31.379 green wire you know because it just 00:03:32.68900:03:32.699 turns the fan on if you were to try to 00:03:36.86000:03:36.870 jump the Y and the red out then there 00:03:40.90900:03:40.919 would be no 5 minute on delay to keep 00:03:44.27000:03:44.280 the compressor safe so if you were to 00:03:45.67900:03:45.689 turn these on and the compressor turned 00:03:47.89900:03:47.909 on and then you turn the compressor off 00:03:51.05000:03:51.060 and then immediately turn it back on 00:03:52.24900:03:52.259 again that will do damage to the 00:03:53.44900:03:53.459 compressor and you don't want to do that 00:03:55.15900:03:55.169 all right so in in the thermostat here 00:03:57.58900:03:57.599 there's a 5 minute on delay between when 00:04:01.90900:04:01.919 you've turn the compressor off when you 00:04:04.24900:04:04.259 turn it back on again 00:04:05.17900:04:05.189 just just to keep the compressor safe 00:04:07.24900:04:07.259 all right but anyway so if you just 00:04:09.25900:04:09.269 connect the red and the G wires together 00:04:11.92900:04:11.939 we can connect them with alligator clips 00:04:18.12900:04:18.139 or if you don't have that just a simple 00:04:21.37900:04:21.389 wire nut will do you can connect it like 00:04:24.83000:04:24.840 this or you could wire knock them 00:04:28.01000:04:28.020 together like this 00:04:33.55000:04:33.560 all right now you go ahead and turn your 00:04:36.46000:04:36.470 furnace back on you see that turn your 00:04:42.56000:04:42.570 furnace back on and see if the fan turns 00:04:47.78000:04:47.790 on all right if it does not turn on then 00:04:50.63000:04:50.640 your problems back at your furnace all 00:04:52.58000:04:52.590 right so that's how you would do all 00:04:57.05000:04:57.060 right if you wanted to turn the power 00:04:59.12000:04:59.130 back off to your furnace and why are not 00:05:01.13000:05:01.140 the or and the white wire together to 00:05:03.41000:05:03.420 see if you your heat will turn on the 00:05:05.06000:05:05.070 sequence of operation of your heat will 00:05:06.44000:05:06.450 turn on then you can do that too I would 00:05:08.63000:05:08.640 just be careful with make sure your 00:05:10.97000:05:10.980 furnace is off first of all I will be 00:05:12.80000:05:12.810 careful with maybe touching this to the 00:05:15.59000:05:15.600 yellow wire because you don't want to do 00:05:17.21000:05:17.220 damage to that compressor because it's 00:05:19.88000:05:19.890 going to have low pressure refrigerant 00:05:21.71000:05:21.720 on one side high pressure refrigerant on 00:05:23.45000:05:23.460 the other side and it's going to have a 00:05:24.77000:05:24.780 heck of a time trying to turn back on if 00:05:27.11000:05:27.120 it hasn't been given a chance to 00:05:29.12000:05:29.130 equalize those refrigerants so the 00:05:30.68000:05:30.690 simplest thing is to just connect the 00:05:32.87000:05:32.880 red and the gene together all right so 00:05:35.18000:05:35.190 that's it that's how you tell if your 00:05:37.22000:05:37.230 thermostat is bad if that fan does 00:05:39.20000:05:39.210 tunnel come on then you just need to 00:05:41.18000:05:41.190 replace this thermostat right right as 00:05:43.58000:05:43.590 I've said before just make sure your 00:05:46.46000:05:46.470 powers off while you're doing it all 00:05:48.83000:05:48.840 right okay out a good time and see you 00:05:51.62000:05:51.630 next time at AC service calm
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12