Visible Defects Heat Exchanger Inspection System - Locate Cracks in Gas Furnace Combustion Cells

WEBVTT
Kind: captions
Language: en

00:00:03.610
I'd like to thank you for purchasing
00:00:05.400 00:00:05.410 visible defects visual detection system
00:00:07.799 00:00:07.809 for fighting tracked heat exchangers
00:00:09.240 00:00:09.250 featuring the contractors crack finder
00:00:11.459 00:00:11.469 with a low odor no smoke non-toxic dye
00:00:15.119 00:00:15.129 penetrant used to find cracks and heat
00:00:17.760 00:00:17.770 exchangers your visual inspection kit
00:00:21.090 00:00:21.100 includes our patent-pending spray
00:00:22.920 00:00:22.930 applicator to spray nozzles and
00:00:25.350 00:00:25.360 inspection mirror safety glasses and a
00:00:28.590 00:00:28.600 UV flashlight for detecting the dye i'd
00:00:32.970 00:00:32.980 like to demonstrate how to use our
00:00:34.290 00:00:34.300 product most heat exchangers have very
00:00:36.750 00:00:36.760 limited access to get to the heat
00:00:38.130 00:00:38.140 exchanger if the crack is where you
00:00:39.960 00:00:39.970 can't view it either from the a coil
00:00:41.340 00:00:41.350 access through the blower or maybe
00:00:43.380 00:00:43.390 through the insertion limit hole you
00:00:44.700 00:00:44.710 have no way of finding any cracks that
00:00:46.440 00:00:46.450 might be visible otherwise the visible
00:00:48.990 00:00:49.000 defects visual detection system is
00:00:50.760 00:00:50.770 especially useful on heat exchangers
00:00:52.319 00:00:52.329 where portions of the heat exchanger and
00:00:53.729 00:00:53.739 not visible for inspection
00:00:55.610 00:00:55.620 serpentine types heat exchangers due to
00:00:58.440 00:00:58.450 their shape after you get through the
00:01:01.380 00:01:01.390 first pass you cannot do any inspections
00:01:04.009 00:01:04.019 whenever you use our product please be
00:01:06.300 00:01:06.310 safe always wear your safety glasses
00:01:08.420 00:01:08.430 turn off all electrical power to the
00:01:10.620 00:01:10.630 unit you're servicing pull the blower
00:01:13.289 00:01:13.299 motor and lay down towels around the
00:01:15.840 00:01:15.850 perimeter of the blower compartment to
00:01:17.100 00:01:17.110 make sure that none of this dye leaks on
00:01:18.870 00:01:18.880 mrs. Smith's white carpet it is bright
00:01:20.490 00:01:20.500 green the visible defects visual
00:01:23.130 00:01:23.140 detection system is sent around our
00:01:25.920 00:01:25.930 fluorescent dye penetrant and the spray
00:01:28.800 00:01:28.810 bar applicator the spray bar applicator
00:01:31.469 00:01:31.479 will go through any hole in a helix in a
00:01:34.859 00:01:34.869 furnace cabinet and if there aren't
00:01:37.020 00:01:37.030 enough holes you can make your own screw
00:01:38.399 00:01:38.409 hole you do this by measuring between
00:01:40.469 00:01:40.479 the cells and then transposing those on
00:01:43.140 00:01:43.150 the front panel using as your insertion
00:01:46.560 00:01:46.570 limit as the point of starting the way
00:01:49.920 00:01:49.930 to use this is we take the 11 inch spray
00:01:51.870 00:01:51.880 bar we insert it in a screw hole or
00:01:55.590 00:01:55.600 through the insertion limit you notice
00:01:57.090 00:01:57.100 it'll get about halfway through the heat
00:01:58.320 00:01:58.330 exchanger then as we spray it sprays the
00:02:00.690 00:02:00.700 holy heat exchanger top to bottom now if
00:02:05.730 00:02:05.740 we're in a closet and we don't have
00:02:07.170 00:02:07.180 access to the back of the heat exchanger
00:02:09.600 00:02:09.610 to insert it from the rear to get the
00:02:11.250 00:02:11.260 back half there's a spray nozzle then we
00:02:13.800 00:02:13.810 put on the hose and then we can soak
00:02:17.170 00:02:17.180 the back of the heat exchanger without
00:02:19.149 00:02:19.159 getting access to the back of the
00:02:20.800 00:02:20.810 furnace
00:02:21.360 00:02:21.370 once you've saturated the air side of
00:02:23.679 00:02:23.689 the heat exchanger you want to take your
00:02:25.000 00:02:25.010 backlight flashlight and look at the
00:02:26.920 00:02:26.930 combustion side of the cells through the
00:02:28.690 00:02:28.700 burner openings any evidence of the
00:02:31.449 00:02:31.459 green dye penetrating is evidence that
00:02:34.360 00:02:34.370 you have a cracker hole that needs
00:02:36.729 00:02:36.739 further investigation on some modern
00:02:39.699 00:02:39.709 crimp style heat exchangers the dye will
00:02:41.679 00:02:41.689 penetrate through this will be a very
00:02:43.240 00:02:43.250 minut amount in the seams where the two
00:02:45.640 00:02:45.650 halves of the heat exchanger meet this
00:02:47.470 00:02:47.480 is normal
00:02:48.280 00:02:48.290 any excessive dye or flooding of the
00:02:50.500 00:02:50.510 chambers would be indication of a much
00:02:52.420 00:02:52.430 serious problem hole or crack
00:02:55.790 00:02:55.800 I would always recommend using a camera
00:02:59.120 00:02:59.130 to document any cracks you find because
00:03:01.310 00:03:01.320 your competitors may not have the same
00:03:03.110 00:03:03.120 tools that you have that allowed you to
00:03:04.970 00:03:04.980 find these cracks in a camera with the
00:03:07.280 00:03:07.290 videotape is really the only way you can
00:03:09.080 00:03:09.090 document it to your customer that they
00:03:10.880 00:03:10.890 have a problem in a format that they
00:03:12.890 00:03:12.900 understand everybody watches TV and if
00:03:15.350 00:03:15.360 they see a crack on TV it looks more
00:03:17.510 00:03:17.520 like a cracked and trying to have them
00:03:19.310 00:03:19.320 bend down and look up inside a small
00:03:20.990 00:03:21.000 hole at something they've never seen
00:03:22.790 00:03:22.800 before so I would always recommend using
00:03:24.860 00:03:24.870 a camera you can use ours or use
00:03:26.900 00:03:26.910 somebody else's but always document
00:03:28.640 00:03:28.650 cracks you find it's for your own
00:03:29.990 00:03:30.000 protection I'd like to take this
00:03:32.270 00:03:32.280 opportunity to thank you for investing
00:03:34.100 00:03:34.110 in visible defects visible detection
00:03:36.200 00:03:36.210 system