Wabash Power 800HP Mobile Steam Plant - Portable Boiler Room Rentals

WEBVTT
Kind: captions
Language: en

00:00:08.260
wabash power is a worldwide leader in
00:00:11.289 00:00:11.299 rental boilers we have one of the
00:00:13.450 00:00:13.460 largest and newest fleets of rental
00:00:15.459 00:00:15.469 boilers worldwide in addition to our
00:00:18.040 00:00:18.050 packaged water-tube boilers Wabash also
00:00:21.250 00:00:21.260 builds mobile steam plants at our
00:00:22.960 00:00:22.970 headquarters in Wheeling Illinois
00:00:33.049 00:00:33.059 the 800 horsepower mobile steam plant
00:00:35.869 00:00:35.879 from Wabash Power offers a complete
00:00:38.330 00:00:38.340 mobile boiler room solution Inlet
00:00:48.650 00:00:48.660 connections are provided for natural gas
00:00:50.509 00:00:50.519 city water and condensate return there
00:00:53.810 00:00:53.820 is also a connection for number two oil
00:00:55.880 00:00:55.890 which our units are capable of operating
00:00:57.889 00:00:57.899 on the water first goes through a
00:01:01.340 00:01:01.350 preliminary filter from the filter the
00:01:03.619 00:01:03.629 water goes to the water softener the
00:01:05.990 00:01:06.000 duplex water softener system runs the
00:01:08.480 00:01:08.490 water through one softener tank while
00:01:10.310 00:01:10.320 the other is regenerating or in standby
00:01:12.560 00:01:12.570 the softener removes calcium magnesium
00:01:14.960 00:01:14.970 and other dissolved solids before the
00:01:17.660 00:01:17.670 water goes to the feed system from the
00:01:19.910 00:01:19.920 softener the water goes to the deaerator
00:01:21.980 00:01:21.990 the water is prepped reducing the
00:01:24.050 00:01:24.060 surface tension so heating and agitating
00:01:26.450 00:01:26.460 can separate the corrosive gases oxygen
00:01:28.999 00:01:29.009 and free carbon dioxide this is the
00:01:31.550 00:01:31.560 makeup water that is combined with the
00:01:33.469 00:01:33.479 condensate to make the feed water the
00:01:35.719 00:01:35.729 result is a more energy efficient system
00:01:38.709 00:01:38.719 there are two chemical tanks the tank on
00:01:41.840 00:01:41.850 the Left feeds directly into the
00:01:43.580 00:01:43.590 deaerator the tank on the right injects
00:01:45.830 00:01:45.840 chemicals into the feed water line after
00:01:48.289 00:01:48.299 it is left the deaerator chemical
00:01:49.999 00:01:50.009 control of the water allows for steam
00:01:51.920 00:01:51.930 purity by removing suspended and
00:01:53.840 00:01:53.850 dissolved solids the mobile steam plant
00:01:57.170 00:01:57.180 from Wabash Power is equipped with
00:01:59.179 00:01:59.189 several control systems that work in
00:02:00.980 00:02:00.990 harmony they oversees steam pressure
00:02:02.899 00:02:02.909 feed water flow
00:02:04.340 00:02:04.350 fuel and air settings and burner
00:02:06.319 00:02:06.329 management the boiler feedwater pumps
00:02:11.330 00:02:11.340 with their controls are used to pump
00:02:13.039 00:02:13.049 feed water into the boiler Wabash uses
00:02:15.979 00:02:15.989 three feed water pumps with variable
00:02:17.870 00:02:17.880 frequency drives or VFDs
00:02:19.910 00:02:19.920 to match the boiler operating pressure
00:02:25.190 00:02:25.200 the heart of the mobile steam plant is a
00:02:28.140 00:02:28.150 cleaver Brooks 800 horsepower to pass
00:02:30.720 00:02:30.730 firetube boiler the boiler has a design
00:02:33.179 00:02:33.189 pressure of 250 psi with an integrated
00:02:36.390 00:02:36.400 low NOx burner the burner produces high
00:02:39.089 00:02:39.099 heat in the combustion chamber this is
00:02:42.300 00:02:42.310 the first pass the hot gases then
00:02:47.009 00:02:47.019 traveled back through the smaller tubes
00:02:48.809 00:02:48.819 to the exhaust chamber and out the stack
00:02:51.569 00:02:51.579 this is the second pass the combined
00:02:54.000 00:02:54.010 passes produce good heat transferred
00:02:55.860 00:02:55.870 fast evaporation and higher thermal
00:02:57.839 00:02:57.849 efficiency at full capacity the boiler
00:03:00.330 00:03:00.340 can produce up to twenty seven thousand
00:03:02.369 00:03:02.379 six hundred pounds of saturated steam
00:03:04.110 00:03:04.120 per hour
00:03:04.710 00:03:04.720 a blowdown tank is included for
00:03:10.140 00:03:10.150 intermittent blow downs
00:03:11.490 00:03:11.500 this ensures removal of impurities that
00:03:13.710 00:03:13.720 have settled at the bottom of the boiler
00:03:16.069 00:03:16.079 each mobile steam plant from Wabash
00:03:18.869 00:03:18.879 power is pre piped pre insulated and
00:03:21.300 00:03:21.310 also pre-wired for a convenient single
00:03:23.879 00:03:23.889 point electrical connection they are
00:03:25.860 00:03:25.870 assembled and test-fired at our
00:03:27.569 00:03:27.579 headquarters in Wheeling Illinois by
00:03:29.699 00:03:29.709 combining each component of a boiler
00:03:31.800 00:03:31.810 room into a 53-foot mobile container
00:03:34.009 00:03:34.019 customers can ensure a smaller footprint
00:03:36.449 00:03:36.459 and minimize installation time in the
00:03:38.789 00:03:38.799 field
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12

Phone: +7 343 216 77 75

E-mail: info@lotus1.ru

Sales phone

Russia: +7 343 216 77 75