What to look for if you get central heating, but no hot water.
WEBVTT Kind: captions Language: en
00:00:00.089 hi one big al um what to do if you find 00:00:04.57900:00:04.589 you've got heating it's all running 00:00:07.61000:00:07.620 nicely but absolutely no hot water at 00:00:10.45900:00:10.469 all what sort of thing do you need to 00:00:13.58000:00:13.590 look for um so I'm gonna ask one Oh 00:00:16.22000:00:16.230 Benny has asked me for this one again so 00:00:18.59000:00:18.600 anybody else that needs to know this one 00:00:20.96000:00:20.970 this is the only answers I have for you 00:00:22.84900:00:22.859 being a plumber this is a man I'm 00:00:25.00900:00:25.019 sticking with um it's a couple of things 00:00:27.14000:00:27.150 first of all if you've got a combi 00:00:28.46000:00:28.470 boiler tough luck really you might as 00:00:36.20000:00:36.210 well just get a engineering I'm afraid 00:00:39.76000:00:39.770 that's so complex inside it could be 00:00:42.86000:00:42.870 many things okay so this refers to 00:00:44.84000:00:44.850 really a domestic heating system with a 00:00:48.08000:00:48.090 conventional boiler hot water cylinder 00:00:51.29000:00:51.300 and fne header tank guys we've got that 00:00:55.18900:00:55.199 type of system this is for you if you've 00:00:57.17000:00:57.180 got combi boiler 00:00:58.18900:00:58.199 you better start calling the heating 00:01:00.47000:01:00.480 engineer right this minute because it's 00:01:02.38900:01:02.399 a bigger problem than you think okay get 00:01:05.09000:01:05.100 that one out of the way now we're going 00:01:06.59000:01:06.600 to move on okay what to look for um the 00:01:09.23000:01:09.240 first most one the most one it uses is a 00:01:12.59000:01:12.600 40 motorized valve if you've got a 00:01:16.60900:01:16.619 system with two motorized valves which a 00:01:19.21900:01:19.229 lot of common systems do have you may 00:01:22.03900:01:22.049 find that the valve that controls the 00:01:25.66000:01:25.670 central heat you know is fine and it's 00:01:30.71000:01:30.720 running but the hot water one has gone 00:01:33.46900:01:33.479 down and you can check that by it 00:01:35.92900:01:35.939 actually there is a little leaver you 00:01:38.21000:01:38.220 see if I show you this now I'm going to 00:01:40.16000:01:40.170 show them draw I've got here now okay 00:01:42.95000:01:42.960 down there and there's my little drawing 00:01:45.80000:01:45.810 but over there and there's our boiler 00:01:49.03900:01:49.049 and there's our flow going up and ran 00:01:51.17000:01:51.180 and if you've got two motorized valves 00:01:53.21000:01:53.220 like this um well they've got little 00:01:56.38900:01:56.399 levers on the bottom generally um 00:01:58.81900:01:58.829 now once for hot water you can see it 00:02:01.21900:02:01.229 goes into the cylinder and goes around a 00:02:03.17000:02:03.180 corner comes out 00:02:04.35000:02:04.360 and it goes back to your boiler but that 00:02:08.16000:02:08.170 that one could be a 41 and you can tell 00:02:11.31000:02:11.320 by pulling that lever across manually if 00:02:13.53000:02:13.540 you put it across manually in your opens 00:02:15.39000:02:15.400 up you'll find you'll be able to get hot 00:02:17.55000:02:17.560 water again it means it isn't working 00:02:20.10000:02:20.110 properly and it could well be the 00:02:22.17000:02:22.180 cylinder stat and so for not calling 00:02:24.24000:02:24.250 heat for it so it could be even a stat 00:02:26.94000:02:26.950 there or the actual motorized bowel 00:02:28.68000:02:28.690 normally nine times out of ten is the 00:02:30.81000:02:30.820 motorized valve that's gone and 00:02:33.18000:02:33.190 generally that is the case to me knew 00:02:35.79000:02:35.800 that valve there you can just get a head 00:02:37.92000:02:37.930 doing it for the right model and replace 00:02:39.48000:02:39.490 it fairly easily okay 00:02:41.76000:02:41.770 that's genuinely the main cause if 00:02:44.40000:02:44.410 you've got motorized batteries generally 00:02:46.80000:02:46.810 most most new modern systems do have and 00:02:49.89000:02:49.900 that can be the problem and I say very 00:02:52.23000:02:52.240 rarely again may be that the step okay 00:02:55.50000:02:55.510 that covers the motorized valve system 00:02:57.42000:02:57.430 there's a more modern one but there are 00:02:59.64000:02:59.650 some systems around that are very old 00:03:03.42000:03:03.430 and if you've got one twenty thirty 00:03:05.25000:03:05.260 years old it doesn't have any motorized 00:03:06.84000:03:06.850 valves and it relies on gravity to 00:03:10.10000:03:10.110 circulate the hot water so if you've got 00:03:13.44000:03:13.450 this type of system this is what can 00:03:15.24000:03:15.250 quite commonly happen um if I show you 00:03:18.24000:03:18.250 this drawing you'll see here that here 00:03:22.68000:03:22.690 we've got our boil up and quite often in 00:03:25.14000:03:25.150 this is my house actually this is this 00:03:27.00000:03:27.010 is our good gravity and the flow goes up 00:03:29.84000:03:29.850 and it goes across the top of the loft 00:03:32.46000:03:32.470 like this and drops down into the 00:03:35.40000:03:35.410 cylinder now I mean it can go up and 00:03:38.49000:03:38.500 still cut across and not have too much 00:03:40.17000:03:40.180 here to get into the cylinder there into 00:03:42.33000:03:42.340 the flow and then the oddity to return 00:03:43.94900:03:43.959 comes down and goes back to the boiler 00:03:45.63000:03:45.640 but what can happen over the summer 00:03:47.72900:03:47.739 period is this little F and E tank in 00:03:50.75900:03:50.769 your loft space I've drawn as the loft 00:03:53.19000:03:53.200 space um that bull cocking near can jam 00:03:57.21000:03:57.220 up that jams up over the summer period 00:04:00.12000:04:00.130 because it's not feeling much because 00:04:01.50000:04:01.510 you're not using your heat or anything 00:04:02.82000:04:02.830 so that's got no expansion to take up it 00:04:05.43000:04:05.440 can stick and then that water level 00:04:07.59000:04:07.600 drops away and gradually for the summer 00:04:10.11000:04:10.120 um it back rates away and your boil is 00:04:12.87000:04:12.880 still probably going for the hot water 00:04:13.98000:04:13.990 so you are using some evaporate 00:04:16.55000:04:16.560 well eventually the water level drops 00:04:18.56000:04:18.570 down and down to it dropped below here 00:04:20.96000:04:20.970 and in here is in allowed to enter here 00:04:23.96000:04:23.970 and once you've got that in there your 00:04:26.63000:04:26.640 whole was stopped dead and and you may 00:04:29.69000:04:29.700 find that some of the rats are still go 00:04:31.55000:04:31.560 because they're on a bottom level 00:04:32.87000:04:32.880 they're lower they're on the on the 00:04:34.55000:04:34.560 floor level if you like and they may 00:04:36.83000:04:36.840 still keep going because they've got war 00:04:39.11000:04:39.120 in them but you would definitely a hot 00:04:40.73000:04:40.740 wall of a of grinding halt and this 00:04:43.10000:04:43.110 is a system as I say that's got no 00:04:44.78000:04:44.790 motorized valves inning at all and 00:04:47.81000:04:47.820 relies entirely on gravity and there are 00:04:49.88000:04:49.890 still quite a few those old systems 00:04:51.32000:04:51.330 around so that it's always a first pour 00:04:53.57000:04:53.580 call if you've got this problem with an 00:04:56.54000:04:56.550 old system get up in the loft there and 00:04:58.31000:04:58.320 check that little tank and see if it's 00:05:01.66000:05:01.670 got warning and if it hasn't you name it 00:05:04.67000:05:04.680 a problem if it hasn't just got that 00:05:06.44000:05:06.450 ball and armor shake long that's all it 00:05:09.08000:05:09.090 needs 00:05:09.47000:05:09.480 move up and down and it will crack and 00:05:12.11000:05:12.120 gradu dog will start to pour back in 00:05:14.00000:05:14.010 again make sure it shuts off okay and if 00:05:17.33000:05:17.340 in doubt we'll put a new ball valve in 00:05:19.55000:05:19.560 there not much money anyway if you wanna 00:05:22.10000:05:22.110 be safe than sorry and it might happen 00:05:23.42000:05:23.430 again in the future be near the ball 00:05:25.49000:05:25.500 valve and you know you've got that 00:05:26.57000:05:26.580 problem sorry 00:05:27.65000:05:27.660 and that generally is around about it 00:05:29.77000:05:29.780 that's all the problems to do with hot 00:05:33.44000:05:33.450 water so I think about covers that one 00:05:35.42000:05:35.430 thanks very much for watching guys and 00:05:37.06000:05:37.070 tune in to my channel dirt and 33 for 00:05:39.80000:05:39.810 any more tips plumbing heating and DIY 00:05:42.14000:05:42.150 thanks for watching
Office location
Engineering company LOTUS®
Russia, Ekaterinburg, Lunacharskogo street, 240/12